A disposable microfluidic cassette for DNA amplification and detection

被引:100
作者
Wang, J
Chen, ZY
Corstjens, PLAM
Mauk, MG
Bau, HH [1 ]
机构
[1] Univ Penn, Dept Mech Engn & Appl Mech, Philadelphia, PA 19104 USA
[2] Leiden Univ, Med Ctr, Dept Mol Cell Biol, NL-2333 AL Leiden, Netherlands
关键词
D O I
10.1039/b511494b
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A pneumatically driven, disposable, microfluidic cassette comprised of a polymerase chain reaction (PCR) thermal cycler, an incubation chamber to label PCR amplicons with up-converting phosphor (UPT) reporter particles, conduits, temperature-activated, normally closed hydrogel valves, and a lateral flow strip, was constructed and tested. The hydrogel valves, which were opened and closed with the aid of electrically controlled thermoelectric units, provided a simple means to seal the PCR reactor and suppress bubble formation. The hydrogel-based flow control was electronically addressable, leakage-free, and biocompatible. To test the device, a solution laden with genomic DNA isolated from B. cereus was introduced into the microfluidic cassette and a specific 305 bp fragment was amplified. The PCR amplicons were labelled with the phosphor (UPT) reporter particles, applied to the lateral flow strip, bound to pre-immobilized ligands, and detected with an IR laser that scanned the lateral flow strip and excited the phosphor (UPT) particles that, in turn, emitted light in the visible spectrum. The UPT particles do not bleach, they provide a permanent record, and they readily facilitate the filtering of background noise. The cassette described herein will be used for rapid testing at the point of care.
引用
收藏
页码:46 / 53
页数:8
相关论文
共 34 条
  • [1] A miniature integrated device for automated multistep genetic assays
    Anderson, Rolfe C.
    Su, Xing
    Bogdan, Gregory J.
    Fenton, Jeffery
    [J]. NUCLEIC ACIDS RESEARCH, 2000, 28 (12)
  • [2] Comparison of point-of-collection screening of drugs of abuse in oral fluid with a laboratory-based urine screen
    Barrett, C
    Good, C
    Moore, C
    [J]. FORENSIC SCIENCE INTERNATIONAL, 2001, 122 (2-3) : 163 - 166
  • [3] An integrated nanoliter DNA analysis device
    Burns, MA
    Johnson, BN
    Brahmasandra, SN
    Handique, K
    Webster, JR
    Krishnan, M
    Sammarco, TS
    Man, PM
    Jones, D
    Heldsinger, D
    Mastrangelo, CH
    Burke, DT
    [J]. SCIENCE, 1998, 282 (5388) : 484 - 487
  • [4] Quantum dot bioconjugates for ultrasensitive nonisotopic detection
    Chan, WCW
    Nie, SM
    [J]. SCIENCE, 1998, 281 (5385) : 2016 - 2018
  • [5] Corstjens P, 2001, CLIN CHEM, V47, P1885
  • [6] Corstjens P. L. A. M., 2005, IEE Proceedings Nanobiotechnology, V152, P64, DOI 10.1049/ip-nbt:20045014
  • [7] Upconverting phosphor reporters in immunochromatographic assays
    Hampl, J
    Hall, M
    Mufti, NA
    Yao, YMM
    MacQueen, DB
    Wright, WH
    Cooper, DE
    [J]. ANALYTICAL BIOCHEMISTRY, 2001, 288 (02) : 176 - 187
  • [8] Hong JW, 2001, ELECTROPHORESIS, V22, P328
  • [9] Evaluation of three commercial assays for detection of giardia and cryptosporidium organisms in fecal specimens
    Johnston, SP
    Ballard, MM
    Beach, MJ
    Causer, L
    Wilkins, PP
    [J]. JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (02) : 623 - 626
  • [10] Ketema F, 2001, J ACQ IMMUN DEF SYND, V27, P63, DOI 10.1097/00126334-200105010-00011