Three-dimensional reconstruction of blood vessels in the rabbit eye by X-ray phase contrast imaging

被引:5
作者
Zhang, Lu [1 ]
Qian, Xiuqing [1 ]
Zhang, Kunya [1 ]
Cui, Qianqian [1 ]
Zhao, Qiuyun [1 ]
Liu, Zhicheng [1 ]
机构
[1] Capital Med Univ, Coll Biomed Engn, Beijing 100069, Peoples R China
来源
BIOMEDICAL ENGINEERING ONLINE | 2013年 / 12卷
基金
中国国家自然科学基金;
关键词
Three-dimensional reconstruction; Blood vessels; X-ray phase-contrast imaging; Vessel density; SYNCHROTRON-RADIATION; VISUALIZATION; ALGORITHM; SEGMENTATION; TOMOGRAPHY; TISSUES; CANCER; FUNDUS;
D O I
10.1186/1475-925X-12-30
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: A clear understanding of the blood vessels in the eye is helpful in the diagnosis and treatment of ophthalmic diseases, such as glaucoma. Conventional techniques such as micro-CT imaging and histology are not sufficiently accurate to identify the vessels in the eye, because their diameter is just a few microns. The newly developed medical imaging technology, X-ray phase-contrast imaging (XPCI), is able to distinguish the structure of the vessels in the eye. In this study, XPCI was used to identify the internal structure of the blood vessels in the eye. Methods: After injection with barium sulfate via the ear border artery, an anesthetized rabbit was killed and its eye was fixed in vitro in 10% formalin solution. We acquired images using XPCI at the Shanghai Synchrotron Radiation Facility. The datasets were converted into slices by filtered back-projection (FBP). An angiographic score was obtained as a parameter to quantify the density of the blood vessels. A three-dimensional (3D) model of the blood vessels was then established using Amira 5.2 software. Results: With XPCI, blood vessels in the rabbit eye as small as 18 mu m in diameter and a sixth of the long posterior ciliary artery could be clearly distinguished. In the 3D model, we obtained the level 4 branch structure of vessels in the fundus. The diameters of the arteria centralis retinae and its branches are about 200 mu m, 110 mu m, 95 mu m, 80 mu m and 40 mu m. The diameters of the circulus arteriosus iridis major and its branches are about 210 mu m, 70 mu m and 30 mu m. Analysis of vessel density using the angiographic score showed that the blood vessels had maximum density in the fundus and minimum density in the area anterior to the equator (scores 0.27 +/- 0.029 and 0.16 +/- 0.032, respectively). We performed quantitative angiographic analysis of the blood vessels to further investigate the density of the vessels. Conclusions: XPCI provided a feasible means to determine the structure of the blood vessels in the eye. We were able to determine the diameters and morphological characteristics of the vessels from both 2D images and the 3D model. By analyzing the images, we obtained measurements of the density distribution of the microvasculature, and this approach may provide valuable reference information prior to glaucoma filtration surgery.
引用
收藏
页数:14
相关论文
共 48 条
[1]   PET instrumentation: What are the limits? [J].
Budinger, TF .
SEMINARS IN NUCLEAR MEDICINE, 1998, 28 (03) :247-267
[3]   Conditional QTL mapping for plant height with respect to the length of the spike and internode in two mapping populations of wheat [J].
Cui, Fa ;
Li, Jun ;
Ding, Anming ;
Zhao, Chunhua ;
Wang, Lin ;
Wang, Xiuqin ;
Li, Sishen ;
Bao, Yinguang ;
Li, Xingfeng ;
Feng, Deshun ;
Kong, Lingrang ;
Wang, Honggang .
THEORETICAL AND APPLIED GENETICS, 2011, 122 (08) :1517-1536
[4]   Phase contrast X-ray synchrotron imaging for assessing external and internal morphology of Rhodnius prolixus [J].
de Almeida, Andre P. ;
Soares, Jose ;
Meneses, Anderson A. M. ;
Cardoso, Simone C. ;
Braz, Delson ;
Garcia, Eloi S. ;
Gonzalez, Marcelo S. ;
Azambuja, Patricia ;
Barroso, Regina C. .
APPLIED RADIATION AND ISOTOPES, 2012, 70 (07) :1340-1343
[5]   Enhancement of blood vessels in digital fundus photographs via the application of multiscale line operators [J].
Farnell, D. J. J. ;
Hatfield, F. N. ;
Knox, P. ;
Reakes, M. ;
Spencer, S. ;
Parry, D. ;
Harding, S. P. .
JOURNAL OF THE FRANKLIN INSTITUTE-ENGINEERING AND APPLIED MATHEMATICS, 2008, 345 (07) :748-765
[6]   A micro-tomography method based on X-ray diffraction enhanced imaging for the visualization of micro-organs and soft tissues [J].
Gao, Xin ;
Luo, Shunqian ;
Yin, Hongxia ;
Liu, Bo ;
Xu, Maolin ;
Yuan, Qingxi ;
Gao, Xiulai ;
Zhu, Peiping .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2006, 30 (6-7) :339-347
[7]   Update on aqueous shunts [J].
Gedde, Steven J. ;
Parrish, Richard K., II ;
Budenz, Donald L. ;
Heuer, Dale K. .
EXPERIMENTAL EYE RESEARCH, 2011, 93 (03) :284-290
[8]   Imaging the aqueous humor outflow pathway in human eyes by three-dimensional micro-computed tomography (3D micro-CT) [J].
Hann, Cheryl R. ;
Bentley, Michael D. ;
Vercnocke, Andrew ;
Ritman, Erik L. ;
Fautsch, Michael P. .
EXPERIMENTAL EYE RESEARCH, 2011, 92 (02) :104-111
[9]   Glaucoma drainage devices: A systematic literature review and current controversies [J].
Hong, CH ;
Arosemena, A ;
Zurakowski, D ;
Ayyala, RS .
SURVEY OF OPHTHALMOLOGY, 2005, 50 (01) :48-60
[10]  
Hu ZH, 2010, LECT NOTES COMPUT SC, V6363, P33