The effects of embalming using a 4% formalin solution on the compressive mechanical properties of human cortical bone

被引:121
作者
Ohman, Caroline [1 ,3 ]
Dall'Ara, Enrico [1 ]
Baleani, Massimiliano [1 ]
Jan, Serge Van Sint [2 ]
Viceconti, Marco [1 ]
机构
[1] Ist Ortoped Rizzoli, Lab Tecnol Med, I-40136 Bologna, Italy
[2] Univ Libre Bruxelles, Lab Anat Biomech & Organogenesis, Brussels, Belgium
[3] Univ Bologna, Fac Engn, Bologna, Italy
关键词
Cortical bone; Formalin fixation; Compressive testing; Mechanical properties; Hardness;
D O I
10.1016/j.clinbiomech.2008.07.007
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. The use of formalin fixed bone tissue is often avoided because of its assumed influence on the mechanical properties of bone. Fixed bone tissue would minimise biological risks and eliminate preservation issues for long duration experimental tests. This study aimed to determine the short- and long-term effects of embalming, using a solution with 4% formalin concentration, on the mechanical properties of human cortical bone. Methods. Three-millimetre cylindrical specimens of human cortical bone were extracted from two femoral diaphyses and divided in four groups. The first group was used as control, the remaining three groups were left in the embalming solution for 48 h, 4 week, and 8 week, respectively. Compressive mechanical properties, hardness and ash density were assessed. The last was used to check the homogeneity among the four groups. Findings. No significant differences were found among the four groups in yield stress, ultimate stress and hardness. The specimens stored for 8 week in the embalming solution had significant lower Young's modulus (-24%), higher yield strain (+20%) and ultimate strain (+53%) compared to the other groups. Interpretation. On a short-term perspective, embalming did not affect the compressive mechanical properties, nor hardness of human cortical bone, whereas a long-term preservation (8 week) did significantly affect Young's modulus, yield strain and ultimate strain in compression. Preserving bone segments for up to 4 week in an embalming solution with low formalin concentration seems to be an interesting alternative when collecting and/or managing fresh or fresh-frozen bone segments for biomechanical experiments is not possible. (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1294 / 1298
页数:5
相关论文
共 26 条
[1]   Comparison of the elastic and yield properties of human femoral trabecular and cortical bone tissue [J].
Bayraktar, HH ;
Morgan, EF ;
Niebur, GL ;
Morris, GE ;
Wong, EK ;
Keaveny, TM .
JOURNAL OF BIOMECHANICS, 2004, 37 (01) :27-35
[2]   MECHANICAL-PROPERTIES OF MICROCALLUS IN HUMAN CANCELLOUS BONE [J].
BLACKBURN, J ;
HODGSKINSON, R ;
CURREY, JD ;
MASON, JE .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (02) :237-246
[3]   HARD TISSUE BIOCHEMISTRY - A COMPARISON OF FRESH-FROZEN AND FORMALIN-FIXED TISSUE SAMPLES [J].
BOSKEY, AL ;
COHEN, ML ;
BULLOUGH, PG .
CALCIFIED TISSUE INTERNATIONAL, 1982, 34 (04) :328-331
[4]   EFFECT OF FORMALDEHYDE FIXATION ON SOME MECHANICAL-PROPERTIES OF BOVINE BONE [J].
CURREY, JD ;
BREAR, K ;
ZIOUPOS, P ;
REILLY, GC .
BIOMATERIALS, 1995, 16 (16) :1267-1271
[5]   FORMALIN FIXATION EFFECTS ON VERTEBRAL BONE-DENSITY AND FAILURE MECHANICS - AN IN-VITRO STUDY OF HUMAN AND SHEEP VERTEBRAE [J].
EDMONDSTON, SJ ;
SINGER, KP ;
DAY, RE ;
BREIDAHL, PD ;
PRICE, RI .
CLINICAL BIOMECHANICS, 1994, 9 (03) :175-179
[6]  
EVANS FG, 1973, MECH PROPERTIES BONE, P56
[7]  
Feipel V, 1999, SURG RADIOL ANAT, V21, P175
[8]   EFFECT OF PRESERVATION MEDIUM ON THE MECHANICAL-PROPERTIES OF CAT BONES [J].
GOH, JCH ;
ANG, EJ ;
BOSE, K .
ACTA ORTHOPAEDICA SCANDINAVICA, 1989, 60 (04) :465-467
[9]   HARDNESS, AN INDICATOR OF THE MECHANICAL COMPETENCE OF CANCELLOUS BONE [J].
HODGSKINSON, R ;
CURREY, JD ;
EVANS, GP .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1989, 7 (05) :754-758
[10]  
HORAN MP, 2006, WILEY ENCY BIOMEDICA