摘要
OBJECTIVE. The purpose of this study was to determine in a phantom the dose exposure of different dental 3D sectional imaging methods (CT and cone-beam CT [CBCT]) and different CT protocols. The aim was to establish optimal protocols with the lowest possible dose and diagnostically high image quality with special consideration given to tin prefiltration. MATERIALS AND METHODS. Dose was determined with thermoluminescence detectors at 20 different measuring points on an anthropomorphic phantom. Eight different CT protocols with and without tin filtering were compared with iterative reconstruction methods and a standard CBCT protocol. Objective and subjective image evaluations and a figure-of-merit analysis of the image data were performed by radiologists and maxillofacial surgeons. RESULTS. The determined dose-length products of the nine examinations were 5.0-111.9 mGy.cm with a calculated effective whole body dose of 20.7-505.9 mu Sv. Cone-beam CT was in the upper midfield with an effective dose of 229.3 Pv. On the basis of dose, objective image quality, and clinical evaluation results, tin filter protocols performed best. Protocols with higher doses were significantly less useful in the figure of merit comparison but because of their detailed bony representation are particularly necessary to answer certain questions about trauma and tumors. CONCLUSION. The use of tin filtering can reduce dose in dental CT examinations, compared with standard low-dose examinations, while maintaining good image quality. The dose performance is significantly inferior even to that of a cone-beam CT examination. High-dose protocols are necessary only for certain questions.
引用
收藏
页码:945 / 953
页数:9
相关论文
共 17 条
[1]  
Arcadi Teresa, 2015, Acta Biomed, V86, P77
[2]  
Blobel J, 2013, INVEST RADIOL, V48, P857, DOI 10.1097/RLI.0b013e31829e3932
[3]   Reducing Radiation Dose at CT Colonography: Decreasing Tube Voltage to 100 kVp [J].
Chang, Kevin J. ;
Caovan, Dominique B. ;
Grand, David J. ;
Huda, Walter ;
Mayo-Smith, William W. .
RADIOLOGY, 2013, 266 (03) :791-800
[4]   Cone beam computed tomography for dental and maxillofacial imaging: technique improvement and low-dose protocols [J].
Feragalli, Beatrice ;
Rampado, Osvaldo ;
Abate, Cecilia ;
Macri, Monica ;
Festa, Felice ;
Stromei, Francesco ;
Caputi, Sergio ;
Guglielmi, Giuseppe .
RADIOLOGIA MEDICA, 2017, 122 (08) :581-588
[5]  
Folkerts KH, 2004, THESIS
[6]   Cone-beam computed tomography for routine orthodontic treatment planning: A radiation dose evaluation [J].
Garcia Silva, Maria Alves ;
Wolf, Ulrich ;
Heinicke, Frank ;
Bumann, Axel ;
Visser, Heiko ;
Hirsch, Edgar .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 133 (05) :640.e1-640.e5
[7]   Unenhanced third-generation dual-source chest CT using a tin filter for spectral shaping at 100 kVp [J].
Haubenreisser, Holger ;
Meyer, Mathias ;
Sudarski, Sonja ;
Allmendinger, Thomas ;
Schoenberg, Stefan O. ;
Henzler, Thomas .
EUROPEAN JOURNAL OF RADIOLOGY, 2015, 84 (08) :1608-1613
[8]  
ICRP, 2007, ANN ICRP, V37, DOI DOI 10.1016/J.ICRP.2007.10.003
[9]   Assessment of radiation exposure in dental cone-beam computerized tomography with the use of metal-oxide semiconductor field-effect transistor (MOSFET) dosimeters and Monte Carlo simulations [J].
Koivisto, J. ;
Kiljunen, T. ;
Tapiovaara, M. ;
Wolff, J. ;
Kortesniemi, M. .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2012, 114 (03) :393-400
[10]   Imaging the Parasinus Region with a Third-Generation Dual-Source CT and the Effect of Tin Filtration on Image Quality and Radiation Dose [J].
Lell, M. M. ;
May, M. S. ;
Brand, M. ;
Eller, A. ;
Buder, T. ;
Hofmann, E. ;
Uder, M. ;
Wuest, W. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (07) :1225-1230