Contamination Analysis of Radioactive Samples in Focused Ion Beam Instruments

被引:1
|
作者
Evelan, Audrey Ruth [1 ]
Brey, Richard R. [1 ]
机构
[1] Idaho State Univ, Pocatello, ID 83209 USA
来源
HEALTH PHYSICS | 2013年 / 104卷 / 02期
关键词
operational topics; occupational safety; radioactivity; airborne; surface contamination;
D O I
10.1097/HP.0b013e3182732979
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The use of Focused Ion Beam (FIB) instrument's to analyze and prepare samples that are radioactive requires attentiveness to the materials that are dislodged and five inside the chamber. Radioactive sputtered material must be understood even when observed at trace concentrations. Measurements using liquid scintillation counting and high purity germanium detectors were used to evaluate contamination on accessible surfaces inside a focused ion beam chamber that was used in the preparation of samples that were radioactive. The maximum removable contamination found was 0.27 0.4 Bq cm(-2), on the focused ion beam wall with 0.24 0.019 Bq cm(-2) on the door. Although these magnitudes of removable contamination are inconsequential for activation products, these same magnitudes of actinides, for example Pu-239, would represent 3.2% of an Annual Limit of Intake. This might be considered significant if one examines the relatively infrequent use of this device for the preparation of radioactive samples. Predicted activities of sputtered material were found using the software Transport of Ions in Matter, estimating that 0.003% of a radioactive samples activity is released into the FIB chamber. A used secondary electron detector's activity was measured to be 383.7 8.1 Bq. Preferential build-up of sputtered materials due to temperature or static charge gradients was considered. No temperature gradients were observed. Static charge gradients were measured inside the chamber varying between 0.057% below the mean to 34% higher than the mean. However, the magnitudes of contamination measured did not correlate to static charge gradients. Deposition in the chamber appears to have no mechanical cause but rather is sporadic however, measureable. Experience to date has been limited to samples of low activity; nevertheless, contamination inside the chamber was observed. Users should anticipate higher levels of readily dispersible radioactive contamination within the FIB as sample activity increases. Health Phys. 104(Supplement 1): S23-S30; 2013
引用
收藏
页码:S23 / S30
页数:8
相关论文
共 50 条
  • [41] Selection of targets and ion sources for radioactive ion beam generation at the Holifield Radioactive Ion Beam Facility
    Alton, GD
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1996, 67 (03): : 934 - 934
  • [42] Minimising carbon contamination during ion beam analysis
    Healy, MJF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 129 (01): : 130 - 136
  • [43] Minimising carbon contamination during ion beam analysis
    Cranfield Univ, Wiltshire, United Kingdom
    Nucl Instrum Methods Phys Res Sect B, 1 (130-136):
  • [44] A nanofactory by focused ion beam
    Fujii, T
    Iwasaki, K
    Munekane, M
    Takeuchi, T
    Hasuda, M
    Asahata, T
    Kiyohara, M
    Kogure, T
    Kijima, Y
    Kaito, T
    JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2005, 15 (10) : S286 - S291
  • [45] Focused ion beam metrology
    Wagner, A
    Blauner, P
    Longo, P
    Cohen, S
    ION-SOLID INTERACTIONS FOR MATERIALS MODIFICATION AND PROCESSING, 1996, 396 : 675 - 686
  • [46] Focused ion beam metrology
    Wagner, A.
    Longo, P.
    Cohen, S.
    Blauner, P.
    Journal of Vacuum Science & Technology B: Microelectronics Processing and Phenomena, 1995, 13 (06):
  • [47] Focused chromium ion beam
    Steele, A. V.
    Knuffman, B.
    McClelland, J. J.
    Orloff, J.
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2010, 28 (06): : C6F1 - C6F5
  • [48] Focused ion beam microscope
    不详
    AMERICAN CERAMIC SOCIETY BULLETIN, 2003, 82 (01): : 12 - 12
  • [49] Focused ion beam metrology
    Wagner, A
    Longo, P
    Cohen, S
    Blauner, P
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1995, 13 (06): : 2629 - 2636
  • [50] CONTAMINATION SOURCES IN THE CLEANUP OF SAMPLES FOR INORGANIC-ION ANALYSIS
    BAGCHI, R
    HADDAD, PR
    JOURNAL OF CHROMATOGRAPHY, 1986, 351 (03): : 541 - 547