Electroanalysis of some common pesticides using conducting polymer/multiwalled carbon nanotubes modified glassy carbon electrode

被引:73
作者
Manisankar, P. [1 ]
Sundari, P. L. Abirama [1 ]
Sasikumar, R. [1 ]
Palaniappan, S. P. [1 ]
机构
[1] Alagappa Univ, Dept Ind Chem, Karaikkudi 630003, Tamil Nadu, India
关键词
pesticide analysis; multiwalled carbon nanotubes (MWCNTs); differential pulse stripping voltarnmetry; surface morphology; polymer modified electrodes;
D O I
10.1016/j.talanta.2008.04.056
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The cyclic voltarnmetric behaviour of three common pesticides such as isoproturon (ISO). voltage (VOL) and dicofol (DCF) was investigated at glassy carbon electrode (GCE), multiwalled carbon nanotubes modified GCE (MWCNTs/GCE), polyaniline (PANI) and polypyrrole (PPY) deposited MWCNT/GCE. The modified electrode film was characterized by scanning electron microscopy (SEM) and X-ray diffraction analysis (XRD). The electroactive behaviour of the pesticides was realized from the cyclic voltarnmetric studies. The differential Pulse voltammetric principle was used to analyze the above-mentioned pesticides using MWCNT/GCE, PANI/MWCNT/GCE and PPY/MWCNT/GCE. Effects of accumulation potential. accumulation time. Initial scan potential, amplitude and pulse width were examined for the optimization of stripping conditions. The PANI/MWCNT/GCE performed well among the three electrode systems and the determination range obtained was 0.01 -100 mg L-1 for ISO, VOL and DCF respectively. The limit of detection (LOD) was 0.1 mu g L-1 for ISO, 0.01 mu g L-1 for VOL and 0.05 mu g L-1 for DCF on PANI/MWCNT/GCE modified system. It is significant to note that the PANI/MWCNT/GCE modified system results in the lowest LOD in comparison with the earlier reports. Suitability of this method for the trace determination of pesticide in spiked samples was also realized. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1022 / 1028
页数:7
相关论文
共 35 条
[11]   HELICAL MICROTUBULES OF GRAPHITIC CARBON [J].
IIJIMA, S .
NATURE, 1991, 354 (6348) :56-58
[12]   Metallic conductivity in bamboo-shaped multiwalled carbon nanotubes [J].
Jang, JW ;
Lee, DK ;
Lee, CE ;
Lee, TJ ;
Lee, CJ ;
Noh, SJ .
SOLID STATE COMMUNICATIONS, 2002, 122 (11) :619-622
[13]  
JAYARAMAREDDY S, 1996, ELECTROANAL, V8, P955
[14]   A disposable biosensor for organophosphorus nerve agents based on carbon nanotubes modified thick film strip electrode [J].
Joshi, KA ;
Tang, J ;
Haddon, R ;
Wang, J ;
Chen, W ;
Mulchandani, A .
ELECTROANALYSIS, 2005, 17 (01) :54-58
[15]  
KALVODA R, 1985, ELECTROCHEMISTRY RES, P164
[16]   Carbon nanotubes (CNTs) for the development of electrochemical biosensors [J].
Lin, YH ;
Yantasee, W ;
Wang, J .
FRONTIERS IN BIOSCIENCE, 2005, 10 :492-505
[17]   Immunosensors for pesticide determination in natural waters [J].
Mallat, E ;
Barceló, D ;
Barzen, C ;
Gauglitz, G ;
Abuknesha, R .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (03) :124-132
[18]   Part per trillion level determination of isoproturon in certified and estuarine water samples with a direct optical immunosensor [J].
Mallat, E ;
Barzen, C ;
Abuknesha, R ;
Gauglitz, G ;
Barceló, D .
ANALYTICA CHIMICA ACTA, 2001, 426 (02) :209-216
[19]   Copolymerization of aniline and 4,4′-diaminodiphenyl sulphone and characterization of formed nano size copolymer [J].
Manisankar, P. ;
Vedhi, C. ;
Selvanathan, G. ;
Prabu, H. Gurumallesh .
ELECTROCHIMICA ACTA, 2006, 52 (03) :831-838
[20]   Determination of pesticides using heteropolyacid montmorillonite clay-modified electrode with surfactant [J].
Manisankar, P ;
Selvanathan, G ;
Vedhi, C .
TALANTA, 2006, 68 (03) :686-692