A multi-station hip joint simulator study of the performance of 22 mm diameter zirconia-ultra-high molecular weight polyethylene total replacement hip joints

被引:32
作者
Goldsmith, AAJ [1 ]
Dowson, D [1 ]
机构
[1] Univ Leeds, Sch Mech Engn, Leeds LS2 9JT, W Yorkshire, England
关键词
artificial joint; ceramic; 22 mm zirconia-UHMWPE hip joint replacement; polyethylene; prosthesis; 10-station hip joint simulator;
D O I
10.1243/0954411991534825
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The commissioning of a new form of 10-station hip joint simulator is described and the results of a study of the performance of zirconia-ultra-high molecular weight polyethylene (UHMWPE) total replacement hip joints in the familiar Charnley head size of 7/8 inch (22.225 mm) diameter are presented. The head size is referred to as 22 mm for brevity and consistency throughout the paper. The simulator provided very consistent and repeatable results and the new machine, together with the methods of investigation adopted, offer an excellent facility for the further evaluation of existing and new prostheses. The findings are compared with the outcome of previous laboratory simulator and clinical studies of ceramic-polyethylene implants of similar diameter. It was found that a relatively rapid penetration of the head into the cup was followed by a very low, steady, long-term penetration rate after about two million loading cycles. The mean long-term volumetric penetration rate was 6.28 mm(3)/10(6) loading cycles. When the linear penetration rates were assessed by direct measurement on a coordinate measuring machine, or deduced from the tunnelling expression, the resulting values were very similar and small at 0.019 and 0.016 mm/10(6) loading cycles respectively. It is generally assumed that one million loading cycles is equivalent to about one year of service in the body and if this equivalence is accepted, these penetration rates compare very favourably with a clinical evaluation of alumina heads of the same diameter, which yielded a mean long-term penetration rate of 0.022 mm/year.
引用
收藏
页码:77 / 90
页数:14
相关论文
共 31 条
[1]   Wear of ultra-high molecular weight polyethylene acetabular cups in a physiological hip joint simulator in the anatomical position using bovine serum as a lubricant [J].
Bigsby, RJA ;
Hardaker, CS ;
Fisher, J .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (03) :265-269
[2]   Charnley wear model for validation of hip simulators - Ball diameter versus polytetrafluoroethylene and polyethylene wear [J].
Clarke, IC ;
Good, V ;
Anissian, L ;
Gustafson, A .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (01) :25-36
[3]  
COLLINS SN, 1990, THESIS U LEEDS
[4]   COMPARATIVE-STUDY OF THE WEAR OF UHMWPE WITH ZIRCONIA CERAMIC AND STAINLESS-STEEL FEMORAL HEADS IN ARTIFICIAL HIP JOINTS [J].
DERBYSHIRE, B ;
FISHER, J ;
DOWSON, D ;
HARDAKER, C ;
BRUMMITT, K .
MEDICAL ENGINEERING & PHYSICS, 1994, 16 (03) :229-236
[5]  
DERBYSHIRE B, 1994, P I MECH ENG H, V208, P151
[6]   16- to 25-year follow-up study of cemented arthroplasty of the hip in patients aged 50 years or younger [J].
Devitt, A ;
OSullivan, T ;
Quinlan, W .
JOURNAL OF ARTHROPLASTY, 1997, 12 (05) :479-489
[7]  
DOWSON D, 1985, ACS SYM SER, V287, P171
[8]   AN EVALUATION OF THE PENETRATION OF CERAMIC FEMORAL HEADS INTO POLYETHYLENE ACETABULAR CUPS [J].
DOWSON, D ;
JOBBINS, B ;
SEYEDHARRAF, A .
WEAR, 1993, 162 (pt B) :880-889
[9]  
Dowson D, 1988, Eng Med, V17, P111, DOI 10.1243/EMED_JOUR_1988_017_031_02
[10]  
DOWSON D, 1987, INT C WEAR MAT HOUST, P277