High intensity focused ultrasound ablation of goat liver in vivo: Pathologic changes of portal vein and the "heat-sink" effect

被引:17
|
作者
Jiang, F. [1 ,2 ]
He, M. [1 ,2 ]
Liu, Y. J. [1 ,2 ]
Wang, Z. B. [1 ,2 ,3 ]
Zhang, L. [1 ,2 ,3 ]
Bai, J. [1 ,2 ]
机构
[1] Chongqing Med Univ, State Key Lab Ultrasound Engn Med Cofounded Chong, Chongqing 400016, Peoples R China
[2] Chongqing Med Univ, Dept Biomed Engn, Minist Sci & Technol, Chongqing Key Lab Ultrasound Med & Engn, Chongqing 400016, Peoples R China
[3] Chongqing Med Univ, Affiliated Hosp 2, Clin Ctr Tumor Therapy, Chongqing 400010, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic resonance image-guided high-intensity focused ultrasound (MRgHIFU); Portal vein (PV); T-mapping; Energy deposition; HEPATOCELLULAR-CARCINOMA; SAFE THERAPY; CANCER; OCCLUSION; SURGERY; BREAST; TUMORS; MRI;
D O I
10.1016/j.ultras.2012.04.001
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The purpose of this study was to evaluate pathological changes of the portal vein (PV) and the effects on main branches of the hepatic PV during HIFU (high-intensity focused ultrasound) sonication when liver tissue adjacent to the main branches of hepatic PV was ablated. Normal liver tissue at 0 mm, 5 mm, 10 mm away from the hepatic portal vein in 50 healthy goats was ablated with magnetic resonance image-guided HIFU (MRgHIFU). MRI showed a non-perfusion region at the target area but did not show any significant changes of the PV immediately after HIFU. The histological examination 1 day after HIFU showed coagulative necrosis at the target area, revealed deep-dyed swelling collagen (CS) fibers and vessel wall fracture (VWF) in the PV adjacent to the target area; however, no CS or VWF was observed in the PV 1 week after HIFU ablation. The energy required to ablate the foci at 0 mm was 21% more than that at 10 mm from the PV (p < 0.05); the energy needed to ablate foci 5 mm away from the PV was 10% more than that at 10 mm from the PV (p < 0.05). We concluded that minor injury of the hepatic portal vein may occur when ablating the adjacent liver tissue, and the acoustic energy deposition is related to the distance to the portal vein. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:77 / 83
页数:7
相关论文
共 50 条
  • [21] Microbubble-induced increase in ablation of liver tumors by high-intensity focused ultrasound
    Hanajiri, Kazuyuki
    Maruyama, Toshiyuki
    Kaneko, Yukio
    Mitsui, Hiroshi
    Watanabe, Shunsuke
    Sata, Masataka
    Nagai, Ryozo
    Kashima, Takeshi
    Shibahara, Junji
    Omata, Masao
    Matsumoto, Yoichiro
    HEPATOLOGY RESEARCH, 2006, 36 (04) : 308 - 314
  • [22] The effect of high intensity focused ultrasound on the treatment of liver cancer and patients' immunity
    Ma, Baofeng
    Liu, Xiaoming
    Yu, Zhaoxiao
    CANCER BIOMARKERS, 2019, 24 (01) : 85 - 90
  • [23] Using microbubble contrast agent of different dosage to enhancing liver ablation induced by high-intensity focused ultrasound
    Li, Faqi
    Fu, Liyuan
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 6, 2009, 25 : 39 - +
  • [24] High-Intensity Focused Ultrasound Ablation for the Treatment of Colorectal Liver Metastases During an Open Procedure Study on the Pig
    Parmentier, Hubert
    Melodelima, David
    N'Djin, Apoutou
    Chesnais, Sabrina
    Chapelon, Jean Yves
    Rivoire, Michel
    ANNALS OF SURGERY, 2009, 249 (01) : 129 - 136
  • [25] Biomechanical testing of ex vivo porcine tendons following high intensity focused ultrasound thermal ablation
    Kwan, William Chu
    Partanen, Ari
    Narayanan, Unni
    Waspe, Adam C.
    Drake, James M.
    PLOS ONE, 2024, 19 (05):
  • [26] REAL-TIME SPATIOTEMPORAL CONTROL OF HIGH-INTENSITY FOCUSED ULTRASOUND THERMAL ABLATION USING ECHO DECORRELATION IMAGING IN EX VIVO BOVINE LIVER
    Abbass, Mohamed A.
    Killin, Jakob K.
    Mahalingam, Neeraja
    Hooi, Fong Ming
    Barthe, Peter G.
    Mast, T. Douglas
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (01) : 199 - 213
  • [27] In Vivo Targeted, Responsive, and Synergistic Cancer Nanotheranostics by Magnetic Resonance Imaging-Guided Synergistic High-Intensity Focused Ultrasound Ablation and Chemotherapy
    Tang, Hailin
    Guo, Yuan
    Peng, Li
    Fang, Hui
    Wang, Zhigang
    Zheng, Yuanyi
    Ran, Haitao
    Chen, Yu
    ACS APPLIED MATERIALS & INTERFACES, 2018, 10 (18) : 15428 - 15441
  • [28] Comparison of high-intensity focused ultrasound and microwave ablation for the treatment of small liver metastatic tumors
    Wang, Junjie
    Wan, Lili
    Huang, Guohua
    Chen, Cheng
    Wu, Yakun
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2023, 51 (04)
  • [29] Comparative Study on Transcatheter Arterial Chemoembolization, Portal Vein Embolization and High Intensity Focused Ultrasound Sequential Therapy for Patients
    Cui, Lin
    Liu, Xing-Xiang
    Jiang, Yong
    Wu, Xing-Jun
    Liu, Jian-Jun
    Zhou, Xiang-Rong
    He, Xue-Jun
    Huang, Xin-En
    ASIAN PACIFIC JOURNAL OF CANCER PREVENTION, 2012, 13 (12) : 6257 - 6261
  • [30] Intercostal high intensity focused ultrasound for liver ablation: The influence of beam shaping on sonication efficacy and near-field risks
    de Greef, M.
    Schubert, G.
    Wijlemans, J. W.
    Koskela, J.
    Bartels, L. W.
    Moonen, C. T. W.
    Ries, M.
    MEDICAL PHYSICS, 2015, 42 (08) : 4685 - 4697