Sample temperature effect on laser ablation and analytical capabilities of laser induced breakdown spectroscopy

被引:41
作者
Lednev, V. N. [1 ,2 ]
Grishin, M. Ya. [1 ,3 ]
Sdvizhenskii, P. A. [1 ,2 ]
Asyutin, R. D. [4 ]
Tretyakov, R. S. [4 ]
Stavertiy, A. Ya. [4 ]
Pershin, S. M. [1 ]
机构
[1] Russian Acad Sci, Prokhorov Gen Phys Inst, Moscow, Russia
[2] Natl Univ Sci & Technol MISiS, Moscow, Russia
[3] State Univ, Moscow Inst Phys & Technol, Dolgoprudnyi, Moscow Region, Russia
[4] Bauman Moscow State Tech Univ, Moscow, Russia
基金
俄罗斯科学基金会;
关键词
QUANTITATIVE-ANALYSIS; OPTICAL-EMISSION; LIQUID STEEL; ALLOY-STEEL; MOLTEN; METAL; LIBS; SPECTROMETRY; PLASMAS;
D O I
10.1039/c8ja00348c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The influence of sample temperature on the laser ablation process and analytical capabilities of laser induced breakdown spectroscopy (LIBS) was studied systematically. We were interested in estimating the analytical capabilities of a LIBS probe which was developed for in situ elemental analysis of molten metals during the production of metal parts by additive manufacturing. The sample surface was heated locally (4 mm diameter spot) in an argon atmosphere using a powerful continuous wave fiber laser while a nanosecond laser ablated only a small spot (0.3 mm diameter) in the high temperature area. This procedure can be utilized for high temperature LIBS studies of any samples including materials with high melting temperatures (tungsten, aluminum oxide etc.). Low alloy steel samples were heated up to their melting points and LIBS experiments were carried out in a wide temperature range (25-1600 degrees C). LIBS plasma imaging revealed that the size and brightness of the expanding plume did not depend on solid sample temperature but these parameters increased manifold for molten steel ablation. Comparison of plasma emissivity, temperature and electron density did not reveal any meaningful differences in the case of LIBS measurements for room temperature (25 degrees C), hot solid (1050 degrees C) and molten (1550 degrees C) targets, and thus enhanced plasma emissivity was attributed to greater ablation rate. The surface temperature impact on LIBS analytical capabilities was studied by comparing calibration curve linearity, limits of detection and the root mean square error of cross-validation for chromium, silicon and manganese. High temperature of the sample surface favored greater atomic/ionic line emission but molten sample LIBS analysis revealed poor limits of detection for all elements, which was explained by strong fluctuations of the laser ablation process at the liquid metal surface.
引用
收藏
页码:607 / 615
页数:9
相关论文
共 42 条
[11]   Application of LIBS to the in-line process control of liquid high-alloy steel under pressure [J].
Hubmer, G ;
Kitzberger, R ;
Mörwald, K .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 385 (02) :219-224
[12]   Applications of Laser-Induced Breakdown Spectroscopy (LIBS) in Molten Metal Processing [J].
Hudson, Shaymus W. ;
Craparo, Joseph ;
De Saro, Robert ;
Apelian, Diran .
METALLURGICAL AND MATERIALS TRANSACTIONS B-PROCESS METALLURGY AND MATERIALS PROCESSING SCIENCE, 2017, 48 (05) :2731-2742
[13]   In Situ Synchrotron X-Ray Diffraction and Small Angle X-Ray Scattering Studies on Rapidly Heated and Cooled Ti-Al and Al-Cu-Mg Alloys Using Laser-Based Heating [J].
Kenel, C. ;
Schloth, P. ;
Van Petegem, S. ;
Fife, J. L. ;
Grolimund, D. ;
Menzel, A. ;
Van Swygenhoven, H. ;
Leinenbach, C. .
JOM, 2016, 68 (03) :978-984
[14]  
Kramida A., 2018, READER NIST ASD TEAM, DOI [10.18434/t4w30f, DOI 10.18434/T4W30F]
[15]   Compact diode-pumped Nd:YAG laser for remote analysis of low-alloy steels by laser-induced breakdown spectroscopy [J].
Lednev, V. N. ;
Dormidonov, A. E. ;
Sdvizhenskii, P. A. ;
Grishin, M. Ya ;
Fedorov, A. N. ;
Savvin, A. D. ;
Safronova, E. S. ;
Pershin, S. M. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2018, 33 (02) :294-303
[16]   In situ multi-elemental analysis by laser induced breakdown spectroscopy in additive manufacturing [J].
Lednev, Vasily N. ;
Sdvizhenskii, Pavel A. ;
Asyutin, Roman D. ;
Tretyakov, Roman S. ;
Grishin, Mikhail Ya ;
Stavertiy, Anton Ya ;
Pershin, Sergey M. .
ADDITIVE MANUFACTURING, 2019, 25 :64-70
[17]   Real-time monitoring of laser hot-wire cladding of Inconel 625 [J].
Liu, Shuang ;
Liu, Wei ;
Harooni, Masoud ;
Ma, Junjie ;
Kovacevic, Radovan .
OPTICS AND LASER TECHNOLOGY, 2014, 62 :124-134
[18]   Quantitative analysis of samples at high temperature with remote laser-induced breakdown spectrometry using a room-temperature calibration plot [J].
López-Moreno, C ;
Palanco, S ;
Laserna, JJ .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (7-8) :1034-1039
[19]   Double-pulse laser-induced breakdown spectroscopy for analysis of molten glass [J].
Matiaske, A. -M. ;
Gornushkin, I. B. ;
Panne, U. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (08) :2597-2606
[20]   Fiber-optic laser-induced breakdown spectroscopy of zirconium metal in air: Special features of the plasma produced by a long-pulse laser [J].
Matsumoto, Ayumu ;
Ohba, Hironori ;
Toshimitsu, Masaaki ;
Akaoka, Katsuaki ;
Ruas, Alexandre ;
Sakka, Tetsuo ;
Wakaida, Ikuo .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2018, 142 :37-49