Sample temperature effect on laser ablation and analytical capabilities of laser induced breakdown spectroscopy

被引:41
作者
Lednev, V. N. [1 ,2 ]
Grishin, M. Ya. [1 ,3 ]
Sdvizhenskii, P. A. [1 ,2 ]
Asyutin, R. D. [4 ]
Tretyakov, R. S. [4 ]
Stavertiy, A. Ya. [4 ]
Pershin, S. M. [1 ]
机构
[1] Russian Acad Sci, Prokhorov Gen Phys Inst, Moscow, Russia
[2] Natl Univ Sci & Technol MISiS, Moscow, Russia
[3] State Univ, Moscow Inst Phys & Technol, Dolgoprudnyi, Moscow Region, Russia
[4] Bauman Moscow State Tech Univ, Moscow, Russia
基金
俄罗斯科学基金会;
关键词
QUANTITATIVE-ANALYSIS; OPTICAL-EMISSION; LIQUID STEEL; ALLOY-STEEL; MOLTEN; METAL; LIBS; SPECTROMETRY; PLASMAS;
D O I
10.1039/c8ja00348c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The influence of sample temperature on the laser ablation process and analytical capabilities of laser induced breakdown spectroscopy (LIBS) was studied systematically. We were interested in estimating the analytical capabilities of a LIBS probe which was developed for in situ elemental analysis of molten metals during the production of metal parts by additive manufacturing. The sample surface was heated locally (4 mm diameter spot) in an argon atmosphere using a powerful continuous wave fiber laser while a nanosecond laser ablated only a small spot (0.3 mm diameter) in the high temperature area. This procedure can be utilized for high temperature LIBS studies of any samples including materials with high melting temperatures (tungsten, aluminum oxide etc.). Low alloy steel samples were heated up to their melting points and LIBS experiments were carried out in a wide temperature range (25-1600 degrees C). LIBS plasma imaging revealed that the size and brightness of the expanding plume did not depend on solid sample temperature but these parameters increased manifold for molten steel ablation. Comparison of plasma emissivity, temperature and electron density did not reveal any meaningful differences in the case of LIBS measurements for room temperature (25 degrees C), hot solid (1050 degrees C) and molten (1550 degrees C) targets, and thus enhanced plasma emissivity was attributed to greater ablation rate. The surface temperature impact on LIBS analytical capabilities was studied by comparing calibration curve linearity, limits of detection and the root mean square error of cross-validation for chromium, silicon and manganese. High temperature of the sample surface favored greater atomic/ionic line emission but molten sample LIBS analysis revealed poor limits of detection for all elements, which was explained by strong fluctuations of the laser ablation process at the liquid metal surface.
引用
收藏
页码:607 / 615
页数:9
相关论文
共 42 条
[1]   Double pulse Laser Induced Breakdown Spectroscopy measurements on ITER-like samples [J].
Almaviva, Salvatore ;
Caneve, Luisa ;
Colao, Francesco ;
Gasior, Pawel ;
Kubkowska, Monika ;
Lepek, Michal ;
Maddaluno, Giorgio .
FUSION ENGINEERING AND DESIGN, 2015, 96-97 :848-851
[2]   Characterization of laser induced plasmas by optical emission spectroscopy: A review of experiments and methods [J].
Aragon, C. ;
Aguilera, J. A. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (09) :893-916
[3]   DETERMINATION OF CARBON CONTENT IN MOLTEN STEEL USING LASER-INDUCED BREAKDOWN SPECTROSCOPY [J].
ARAGON, C ;
AGUILERA, JA ;
CAMPOS, J .
APPLIED SPECTROSCOPY, 1993, 47 (05) :606-608
[4]   Additive manufacturing of multi-material structures [J].
Bandyopadhyay, Amit ;
Heer, Bryan .
MATERIALS SCIENCE & ENGINEERING R-REPORTS, 2018, 129 :1-16
[5]   Quality control of laser- and powder bed-based Additive Manufacturing (AM) technologiesro [J].
Berumen, Sebastian ;
Bechmann, Florian ;
Lindner, Stefan ;
Kruth, Jean-Pierre ;
Craeghs, Tom .
LASER ASSISTED NET SHAPE ENGINEERING 6, PROCEEDINGS OF THE LANE 2010, PART 2, 2010, 5 :617-622
[6]   Impurity detection in solid and molten silicon by laser induced breakdown spectroscopy [J].
Darwiche, Sarah ;
Benrabbah, Rafik ;
Benmansour, Malek ;
Morvan, Daniel .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2012, 74-75 :115-118
[7]   Influence of sample temperature on the expansion dynamics and the optical emission of laser-induced plasma [J].
Eschlboeck-Fuchs, S. ;
Haslinger, M. J. ;
Hinterreiter, A. ;
Kolmhofer, P. ;
Huber, N. ;
Roessler, R. ;
Heitz, J. ;
Pedarnig, J. D. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2013, 87 :36-42
[8]   Review of in-situ process monitoring and in-situ metrology for metal additive manufacturing [J].
Everton, Sarah K. ;
Hirsch, Matthias ;
Stravroulakis, Petros ;
Leach, Richard K. ;
Clare, Adam T. .
MATERIALS & DESIGN, 2016, 95 :431-445
[9]   Temperature effect on laser-induced breakdown spectroscopy spectra of molten and solid salts [J].
Hanson, Cynthia ;
Phongikaroon, Supathorn ;
Scott, Jill R. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 97 :79-85
[10]   Compositionally graded metals: A new frontier of additive manufacturing [J].
Hofmann, Douglas C. ;
Kolodziejska, Joanna ;
Roberts, Scott ;
Otis, Richard ;
Dillon, Robert Peter ;
Suh, Jong-Ook ;
Liu, Zi-Kui ;
Borgonia, John-Paul .
JOURNAL OF MATERIALS RESEARCH, 2014, 29 (17) :1899-1910