A time domain based method for the accurate measurement of Q-factor and resonance frequency of microwave resonators

被引:11
|
作者
Gyure, B. [1 ,2 ]
Markus, B. G. [1 ,2 ]
Bernath, B. [1 ,2 ]
Muranyi, F. [3 ]
Simon, F. [1 ,2 ]
机构
[1] Budapest Univ Technol & Econ, Dept Phys, H-1521 Budapest, Hungary
[2] PROSPIN, MTA BME Lendlet Spintron Res Grp, H-1521 Budapest, Hungary
[3] Fdn Res Informat Technol Soc ITIS, CH-8004 Zurich, Switzerland
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2015年 / 86卷 / 09期
基金
欧洲研究理事会;
关键词
CAVITY PERTURBATION TECHNIQUE; SPECTROSCOPY;
D O I
10.1063/1.4929865
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present a novel method to determine the resonant frequency and quality factor of microwave resonators which is faster, more stable, and conceptually simpler than the yet existing techniques. The microwave resonator is pumped with the microwave radiation at a frequency away from its resonance. It then emits an exponentially decaying radiation at its eigen-frequency when the excitation is rapidly switched off. The emitted microwave signal is down-converted with a microwave mixer, digitized, and its Fourier transformation (FT) directly yields the resonance curve in a single shot. Being a FT based method, this technique possesses the Fellgett (multiplex) and Connes (accuracy) advantages and it conceptually mimics that of pulsed nuclear magnetic resonance. We also establish a novel benchmark to compare accuracy of the different approaches of microwave resonator measurements. This shows that the present method has similar accuracy to the existing ones, which are based on sweeping or modulating the frequency of the microwave radiation. (C) 2015 AIP Publishing LLC.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] LARGE DYNAMIC RANGE TIME DOMAIN MEASUREMENT OF Q-FACTOR IN MEMS
    Voigt, S.
    Freitag, M.
    Sorger, A.
    Mehner, J. E.
    2015 TRANSDUCERS - 2015 18TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2015, : 2180 - 2183
  • [22] METHOD OF MEASURING Q-FACTOR OF FEEDTHROUGH WAVEGUIDE RESONATORS
    TURYANSKII, VP
    SOKOLOV, VM
    MEASUREMENT TECHNIQUES, 1975, 18 (11) : 1669 - 1671
  • [23] Exploiting Time-Domain Approach for Extremely High Q-Factor Measurement
    Zhang, Ming
    Llaser, Nicolas
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2015, 64 (10) : 2730 - 2737
  • [24] STEADY-STATE MICROWAVE GENERATORS WITH HIGH Q-FACTOR RESONATORS
    MINAKOVA, II
    PANOV, VI
    RADIOTEKHNIKA I ELEKTRONIKA, 1988, 33 (08): : 1696 - 1705
  • [25] Q-Factor Estimation From the Return Loss of Low-Q Microwave Resonators
    Krolak, Radoslaw
    Fischerauer, Gerhard
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2016, 64 (11) : 3797 - 3806
  • [26] A SIMPLE METHOD FOR MEASUREMENT OF VARACTOR Q-FACTOR
    SMITH, RB
    RADIO AND ELECTRONIC ENGINEER, 1968, 35 (04): : 245 - +
  • [27] COMPARISON METHOD OF MEASUREMENT Q OF MICROWAVE RESONATORS
    KNEPPO, I
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 1977, 25 (05) : 423 - 426
  • [28] ACCURATE MEASUREMENT OF THE Q-FACTOR OF AN OPEN RESONATOR IN THE W-BAND FREQUENCY-RANGE
    MONGIA, RK
    ARORA, RK
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (08): : 3877 - 3880
  • [29] A resonance frequency extraction method from low Q-factor materials based on resonant ultrasound spectroscopy
    Zhang Q.
    Fan F.
    Wang R.
    Shen F.
    Niu H.
    Lixue Xuebao/Chinese Journal of Theoretical and Applied Mechanics, 2019, 51 (05): : 1500 - 1506
  • [30] Accuracy Analysis of Quality Factor Measurement Based on Time Domain Method for MEMS Resonators
    Wang Lingyun
    Du Xiaohui
    Su Yuanzhe
    He Jie
    Li Yipan
    Wu Dezhi
    Sun Daoheng
    MICRO-NANO TECHNOLOGY XV, 2014, 609-610 : 1131 - 1137