Nanopore array derived from L-cysteine oxide/gold hybrids: Enhanced sensing platform for hydroquinone and catechol determination

被引:53
作者
Liu, Weilu [1 ]
Li, Cong [1 ]
Tang, Liu [1 ]
Tong, Aiying [1 ]
Gu, Yue [1 ]
Cai, Rui [1 ]
Zhang, Li [1 ]
Zhang, Zhiquan [1 ]
机构
[1] Jilin Univ, Coll Chem, Changchun 130012, Peoples R China
关键词
L-Cysteine oxide; Gold nanoparticles; Electrocatalysis; Hydroquinone; Catechol; SCANNING ELECTROCHEMICAL MICROSCOPY; GLASSY-CARBON ELECTRODE; BORON-DOPED DIAMOND; CONDUCTING POLYMERS; VOLTAMMETRIC DETERMINATION; HIGH-PERFORMANCE; NANOTUBES; OXIDATION; BEHAVIOR; DERIVATIVES;
D O I
10.1016/j.electacta.2012.10.071
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
In this contribution, the nanopore array derived from L-cysteine oxide/gold hybrids (NA-COGH) was applied to the simultaneous determination of hydroquinone (HQ) and catechol (CT). NA-COGH was prepared by a sequential electrodeposition of L-cysteine oxide and gold into the voids of polystyrene spheres template, followed by removing the template using tetrahydrofuran. Scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and X-ray diffraction (XRD) analyses validated the formation of NA-COGH on the glassy carbon electrode. The charge transfer ability of NA-COGH was studied by means of scanning electrochemical microscopy (SECM). A better charge transfer rate was obtained by optimizing the electrodeposition conditions. More interestingly, the as-prepared NA-COGH presents high electrocatalytic activity for the oxidation of HQ and CT. The sensing platform based on NA-COGH shows a wide linear response for HQ and CT in the concentration range of 4.0 x 10(-7)-6.0 x 10(-4) M and 8.0 x 10(-7)-5.0 x 10(-4) M, with detection limit of 1.9 x 10(-8) M and 3.4 x 10(-8) M (S/N = 3), respectively. Rotating disk electrode experiments revealed that the catalytic rate constants were as high as 7.99 x 10(-3) cm s(-1) and 7.38 x 10(-3) cm s(-1) at potential of 302 mV and 416 mV for HQ and CT, respectively. With good stability and reproducibility, we applied the present method to the simultaneous determination of HQ and CT in tap water and lake water. These results indicate that NA-COGH is a promising electrode material with great potential in electrocatalysis and electrochemical sensing. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:15 / 23
页数:9
相关论文
共 48 条
[1]   Highly sensitive and simultaneous determination of hydroquinone and catechol at poly(thionine) modified glassy carbon electrode [J].
Ahammad, A. J. Saleh ;
Rahman, Md Mahbubur ;
Xu, Guang-Ri ;
Kim, Sunghyun ;
Lee, Jae-Joon .
ELECTROCHIMICA ACTA, 2011, 56 (14) :5266-5271
[2]   Carbon nanoparticle-chitosan composite electrode with anion, cation, and neutral binding sites: Dihydroxybenzene selectivity [J].
Amiri, Mandana ;
Ghaffari, Shahnaz ;
Bezaatpour, Abolfazl ;
Marken, Frank .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 162 (01) :194-200
[3]   ELEMENTARY STEPS OF ELECTROCHEMICAL OXIDATION OF SINGLE-CRYSTAL PLANES OF AU .2. A CHEMICAL AND STRUCTURAL BASIS OF OXIDATION OF THE (111) PLANE [J].
ANGERSTEINKOZLOWSKA, H ;
CONWAY, BE ;
HAMELIN, A ;
STOICOVICIU, L .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1987, 228 (1-2) :429-453
[4]  
Bard A., 2001, Scanning Electrochemical Microscopy
[5]  
Bard A.J, 2002, Student Solutions Manual to accompany Electrochemical Methods: Fundamentals and Applicaitons, V2e
[6]   New analytical approximation of feedback approach curves with a microdisk SECM tip and irreversible kinetic reaction at the substrate [J].
Cornut, R. ;
Lefrou, C. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2008, 621 (02) :178-184
[7]   Seeing Big with Scanning Electrochemical Microscopy [J].
Cortes-Salazar, Fernando ;
Momotenko, Dmitry ;
Girault, Hubert H. ;
Lesch, Andreas ;
Wittstock, Gunther .
ANALYTICAL CHEMISTRY, 2011, 83 (05) :1493-1499
[8]   Determination of polyphenols by high-performance liquid chromatography with inhibited chemiluminescence detection [J].
Cui, H ;
He, CX ;
Zhao, GW .
JOURNAL OF CHROMATOGRAPHY A, 1999, 855 (01) :171-179
[9]   A voltammetric sensor based on graphene-modified electrode for simultaneous determination of catechol and hydroquinone [J].
Du, Haijun ;
Ye, Jianshan ;
Zhang, Jiaqi ;
Huang, Xiaodan ;
Yu, Chengzhong .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 650 (02) :209-213
[10]   USE OF POLYMER-FILMS IN AMPEROMETRIC BIOSENSORS [J].
EMR, SA ;
YACYNYCH, AM .
ELECTROANALYSIS, 1995, 7 (10) :913-923