Using multi-stimulus auditory steady state response to predict hearing thresholds in high-risk infants

被引:11
作者
Chou, Yi-Fan [2 ]
Chen, Peir-Rong [3 ,5 ]
Yu, Szu-Hui [4 ]
Wen, Yu-Hsuan [3 ]
Wu, Hung-Pin [1 ,5 ]
机构
[1] Buddhist Tzuchi Gen Hosp, Dept Otolaryngol, Taichung Branch, Taichung 427, Taiwan
[2] Buddhist Tzuchi Gen Hosp, Dept Otolaryngol, Taipei Branch, Taipei, Taiwan
[3] Buddhist Tzuchi Med Ctr, Dept Otolaryngol, Hualien, Taiwan
[4] Tainan Univ Technol, Dept Mus, Tainan, Taiwan
[5] Tzuchi Univ, Dept Otolaryngol, Sch Med, Hualien, Taiwan
关键词
Evoked response methods; Pure-tone methods; Conditioned play audiometry; Auditory; Physiology; Humans; Infant; Newborn; Premature; Risk Factors; BRAIN-STEM RESPONSES; PURE-TONE AUDIOMETRY; AGED; 4-18; MONTHS; BEHAVIORAL AUDIOMETRY; CLINICAL-APPLICATION; IMPAIRED INFANTS; ADULTS; NEWBORNS; CHILDREN;
D O I
10.1007/s00405-011-1604-0
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
The purpose of this study was to investigate whether multi-stimulus auditory steady-state responses were capable of estimating hearing thresholds in high-risk infants. A retrospective chart review study. Three tertiary referral centers. Infants born between January 2004 and December 2006 who met the criteria for risk factors of congenital hearing loss were enrolled in the study. While under sedation, the multi-stimulus auditory steady-state response was used to determine multi-channel auditory steady-state response thresholds for high-risk infants younger than 13 months. Conditioned play audiometry was then applied to these children at 23-48 months of age to obtain pure tone audiograms. Auditory steady-state response thresholds and pure tone thresholds were then compared. A total of 249 high-risk infants were enrolled in the study. 39 infants were lost during follow-up. The remaining 216 infants completed both examinations. The Pearson correlation coefficients (r) between the ASSR levels and pure tone thresholds were 0.88, 0.94, 0.94 and 0.97 at 500, 1,000, 2,000 and 4,000 Hz, respectively. The strength of the relationship between the auditory steady-state responses and pure tone thresholds increased with more severe degrees of hearing loss and higher frequencies. We conclude that initial multichannel ASSR thresholds measured under sedation are highly correlated with pure tone thresholds obtained 2 or 3 years later. ASSR can be used to predict the frequency-specific hearing thresholds of high-risk infants and can provide information for early hearing intervention.
引用
收藏
页码:73 / 79
页数:7
相关论文
共 27 条
[1]   Comparing pure-tone audiometry and auditory steady state response for the measurement of hearing loss [J].
Ahn, Joong Ho ;
Lee, Hyo-Sook ;
Kim, Young-Jin ;
Yoon, Tae Hyun ;
Chung, Jong Woo .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2007, 136 (06) :966-971
[2]   Year 2007 position statement: Principles and guidelines for early hearing detection and intervention programs [J].
Busa, Jackie ;
Harrison, Judy ;
Chappell, Jodie ;
Yoshinaga-Itano, Christine ;
Grimes, Alison ;
Brookhouser, Patrick E. ;
Epstein, Stephen ;
Mehl, Albert ;
Vohr, Betty ;
Gravel, Judith ;
Roush, Jack ;
Widen, Judith ;
Benedict, Beth S. ;
Scoggins, Bobbie ;
King, Michelle ;
Pippins, Linda ;
Savage, David H. .
PEDIATRICS, 2007, 120 (04) :898-921
[3]   Audiologic evaluation of hearing-impaired infants and children [J].
Callison, DM .
OTOLARYNGOLOGIC CLINICS OF NORTH AMERICA, 1999, 32 (06) :1009-+
[4]   Universal screening for hearing loss in newborns: US preventive services task force recommendation statement [J].
Calonge, Ned ;
Petitti, Diana B. ;
DeWitt, Thomas G. ;
Gordis, Leon ;
Gregory, Kimberly D. ;
Harris, Russell ;
Isham, George ;
LeFevre, Michael L. ;
Loveland-Cherry, Carol ;
Marion, Lucy N. ;
Moyer, Virginia A. ;
Ockene, Judith K. ;
Sawaya, George F. ;
Siu, Albert L. ;
Teutsch, Steven M. ;
Yawn, Barbara P. .
PEDIATRICS, 2008, 122 (01) :143-148
[5]  
Cone-Wesson Barbara, 2002, J Am Acad Audiol, V13, P270
[6]  
Cone-Wesson Barbara, 2002, J Am Acad Audiol, V13, P260
[7]   Universal newborn hearing screening: Are we achieving the Joint Committee on Infant Hearing (JCIH) objectives? [J].
Connolly, JL ;
Carron, JD ;
Roark, SD .
LARYNGOSCOPE, 2005, 115 (02) :232-236
[8]   Behavioral audiometry: protocols for measuring hearing thresholds in babies aged 4-18 months [J].
Delaroche, M ;
Thiebaut, R ;
Dauman, R .
INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2004, 68 (10) :1233-1243
[9]   Behavioral audiometry:: Validity of audiometric measurements obtained using the "Delaroche protocol" in babies aged 4-18 months suffering from bilateral sensorineural hearing loss [J].
Delaroche, Monique ;
Thiebaut, Rodolphe ;
Dauman, Rene .
INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2006, 70 (06) :993-1002
[10]   Newborn hearing screening: Effectiveness, importance of high-risk factors, and characteristics of infants in the neonatal intensive care unit and well-baby nursery [J].
Korres, S ;
Nikolopoulos, TP ;
Komkotou, V ;
Balatsouras, D ;
Kandiloros, D ;
Constantinou, D ;
Ferekidis, E .
OTOLOGY & NEUROTOLOGY, 2005, 26 (06) :1186-1190