Gastrointestinal motility during cardiopulmonary bypass: A sonomicrometric study

被引:3
作者
Gu, Y. John [1 ]
de Kroon, Thom L. [1 ]
Elstrodt, Jan M. [1 ]
Rakhorst, Gerhard [1 ]
机构
[1] Univ Groningen, Med Ctr, Dept Biomed Engn & Cardiothorac Surg, NL-9700 AD Groningen, Netherlands
关键词
cardiopulmonary bypass; gastrointestinal motility; sonomicrometry;
D O I
10.1111/j.1525-1594.2006.00257.x
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Cardiopulmonary bypass (CPB) is known to impair the integrity of the gastrointestinal tract. However, little is known about the movement behavior of the gastrointestinal tract during CPB. This study was aimed to assess the gastrointestinal motility with sonomicrometry, a distance measurement using ultrasound, in a porcine model of CPB. Twelve pigs weighing 70-112 kg were having a standard hypothermic CPB for 120 min either with the nonpulsatile flow (n = 6) or the pulsatile flow (n = 6). Before CPB, piezoelectric echo crystals were placed either along the longitudinal or the circular axis of the pylorus. Patterns of gut movement and the total sonomicrometric activity (TSA) were recorded at several time intervals during experiments as qualitative and quantitative parameters of gut motility. Results showed that the intact regular rhythmic pattern of gut movement was detected before CPB. This pattern changed little when CPB started, but it disappeared at 60 min when the body temperature lowered down to 32 degrees C. During the same period, the TSA reduced significantly along the longitudinal as well as the circular directions of the pylorus. There was no significant difference between the nonpulsatile and pulsatile groups. Gut blood flow reduced significantly in both groups, but it was not associated with the reduced sonomicrometric activity. In conclusion, gastrointestinal motility during CPB can be measured qualitatively and quantitatively by sonomicrometry in a large animal model. Suppression of gut motility during CPB does not seem to be associated with the mode of perfusion but with the reduced body temperature during the hypothermic phase of CPB.
引用
收藏
页码:548 / 553
页数:6
相关论文
共 24 条
[1]   Coordinated gastric and sphincter motility evoked by intravenous CCK-8 as monitored by ultrasonomicrometry in rats [J].
Adelson, DW ;
Million, M ;
Kanamoto, K ;
Palanca, T ;
Taché, Y .
AMERICAN JOURNAL OF PHYSIOLOGY-GASTROINTESTINAL AND LIVER PHYSIOLOGY, 2004, 286 (02) :G321-G332
[2]   Incidence of gastrointestinal complications in cardiopulmonary bypass patients [J].
Byhahn, C ;
Strouhal, U ;
Martens, S ;
Mierdl, S ;
Kessler, P ;
Westphal, K .
WORLD JOURNAL OF SURGERY, 2001, 25 (09) :1140-1144
[3]   Reduction of systolic and diastolic dysfunction by retrograde coronary sinus perfusion during off-pump coronary surgery [J].
Castellá, M ;
Buckberg, GD .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 127 (04) :1018-1025
[4]  
CHITWOOD WR, 1980, J THORAC CARDIOV SUR, V80, P724
[5]  
Desai J. B., 1993, Perfusion, V8, P149
[6]   Cardiopulmonary bypass after 50 years [J].
Edmunds, LH .
NEW ENGLAND JOURNAL OF MEDICINE, 2004, 351 (16) :1603-1606
[7]   Clinical evaluation of reflectance spectrophotometry for the measurement of gastric microvascular oxygen saturation in patients undergoing cardiopulmonary bypass [J].
Fournell, A ;
Schwarte, LA ;
Scheeren, TWL ;
Kindgen-Milles, D ;
Feindt, P ;
Loer, SA .
JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2002, 16 (05) :576-581
[8]   Augmentation of abdominal organ perfusion during cardiopulmonary bypass with a novel intra-aortic pulsatile catheter pump [J].
Gu, YJ ;
De Kroon, T ;
Elstrodt, JM ;
van Oeveren, W ;
Boonstra, PW ;
Rakhorst, G .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2005, 28 (01) :35-43
[9]   DIAMETER AND WALL THICKNESS RECORDING OF CANINE PYLORUS WITH IMPLANTABLE MINIATURE ULTRASONIC TRANSDUCERS [J].
MANDREK, K .
DIGESTIVE DISEASES, 1991, 9 (06) :325-331
[10]   HYPOPERFUSION AS A POSSIBLE FACTOR IN THE DEVELOPMENT OF GASTROINTESTINAL COMPLICATIONS AFTER CARDIAC-SURGERY [J].
MONETA, GL ;
MISBACH, GA ;
IVEY, TD .
AMERICAN JOURNAL OF SURGERY, 1985, 149 (05) :648-650