Changes in strain distribution of loaded proximal femora caused by different types of cementless femoral stems

被引:95
作者
Decking, Ralf
Puhl, Wolfhart
Simon, Ulrich
Claes, Lutz E.
机构
[1] Univ Ulm, Inst Orthopaed Res & Biomech, D-89081 Ulm, Germany
[2] Univ Ulm, Dept Orthopaed Surg, RKU, D-89075 Ulm, Germany
关键词
cementless femoral hip; stemless; strain gauges; cadaver study;
D O I
10.1016/j.clinbiomech.2005.12.011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background A number of clinically used total hip femoral implants are claiming a more or less physiologic load transfer, mostly without providing experimental data. To compare three clinically cementless total hip stems of fundamentally different design, the strain distribution before and after insertion in human cadaver femora was measured in vitro. Methods. A conventional straight stem based on a distal anchorage concept, a so-called "anatomic" stem designed to have a proximal force transmission and a "stemless" femoral neck prosthesis were evaluated under similar loading conditions. Strain distribution was measured with tri-axial strain-gauge rosettes before and after implantation of the stems. The same bending moment was used in all femora tested to compare magnitude and direction of the resulting strains. Findings. The straight and the "anatomic" stem both led to a decrease of the longitudinal strains in the proximal femur, while the femoral neck implant mainly led to an increase of measured strains on the lateral side of the greater trochanter. The observed medial strains were closer to physiological values in the "stemless" prosthesis than those of the two full-stem prosthesis. Interpretation. The decrease in strains seen in the proximal region of the femora with implanted conventional hip prosthesis corresponds well to the decrease of bone density in this region noted in clinical follow-up studies. The more physiological strain at the inferior base of the neck seen in "stemless implant" may induce a remodelling process that better retains bone stock in that area. However, the increase of strains noted after implantation of this prosthesis require further investigation to assess the risk they may pose to bone failure. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:495 / 501
页数:7
相关论文
共 31 条
  • [1] Changes in proximal femoral strain after insertion of uncemented standard and customised femoral stems
    Aamodt, A
    Lund-Larsen, J
    Eine, J
    Andersen, E
    Benum, P
    Husby, OS
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2001, 83B (06): : 921 - 929
  • [2] ALEXEEVA L, 1994, WHO TECH REP SER, V843, P1
  • [3] Periprosthetic bone remodelling after cementless total hip replacement - A prospective comparison of two different implant designs
    Ang, KC
    De, SD
    Goh, JCH
    Low, SL
    Bose, K
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1997, 79B (04): : 675 - 679
  • [4] BOBYN JD, 1992, CLIN ORTHOP RELAT R, P79
  • [5] Changes in bone mineral density in the proximal femur after cementless total hip arthroplasty - A five-year longitudinal study
    Brodner, W
    Bitzan, P
    Lomoschitz, F
    Krepler, P
    Jankovsky, R
    Lehr, S
    Kainberger, F
    Gottsauner-Wolf, F
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (01): : 20 - 26
  • [6] Initial stability of fully and partially cemented femoral stems
    Claes, L
    Fiedler, S
    Ohnmacht, M
    Duda, GN
    [J]. CLINICAL BIOMECHANICS, 2000, 15 (10) : 750 - 755
  • [7] A critical analysis of stress shielding evaluation of hip prostheses
    Cristofolini, L
    [J]. CRITICAL REVIEWS IN BIOMEDICAL ENGINEERING, 1997, 25 (4-5) : 409 - 483
  • [8] In vitro measured strains in the loaded femur: Quantification of experimental error
    Cristofolini, L
    McNamara, BP
    Freddi, A
    Viceconti, M
    [J]. JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN, 1997, 32 (03) : 193 - 200
  • [9] In vitro stress shielding measurements can be affected by large errors
    Cristofolini, L
    Viceconti, M
    [J]. JOURNAL OF ARTHROPLASTY, 1999, 14 (02) : 215 - 219
  • [10] Influence of muscle forces on femoral strain distribution
    Duda, GN
    Heller, M
    Albinger, J
    Schulz, O
    Schneider, E
    Claes, L
    [J]. JOURNAL OF BIOMECHANICS, 1998, 31 (09) : 841 - 846