Reliability of Entire Corneal Thickness Mapping in Normal Post-Laser in situ Keratomileusis and Keratoconus Eyes Using Long Scan Depth Spectral Domain Optical Coherence Tomography

被引:4
作者
Xu, Zhe [1 ]
Chen, Sisi [1 ]
Yang, Chun [1 ]
Huang, Shenghai [1 ]
Shen, Meixiao [1 ]
Wang, Yuanyuan [1 ]
机构
[1] Wenzhou Med Univ, Sch Ophthalmol & Optometry, 270 Xueyuan Rd, Wenzhou 325027, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Entire corneal thickness mapping; Repeatability; Reproducibility; Long scan depth spectral domain optical coherence tomography; ANTERIOR SEGMENT; ULTRASONIC PACHYMETRY; HIGH-SPEED; AUTOMATIC SEGMENTATION; EPITHELIAL THICKNESS; BOWMANS LAYER; CONTACT-LENS; REPEATABILITY; REPRODUCIBILITY; RESOLUTION;
D O I
10.1159/000478985
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the repeatability and reproducibility of mapping the entire corneal thickness using spectral domain optical coherence tomography (SD-OCT). Methods: Thirty normal eyes, 30 post-laser in situ keratomileusis (LASIK) surgery eyes, and 30 keratoconus eyes were analyzed. A custom-built long scan depth SD-OCT device was used to obtain entire corneal images. Ten-millimeter-diameter corneal thickness maps were generated by an automated segmentation algorithm. Intraclass correlation coefficients of repeatability (ICC1) and reproducibility (ICC2), and coefficients of repeatability (CoR1) and reproducibility (CoR2), were calculated to quantify the precision and accuracy of corneal pachymetry measurements using the Bland-Altman method. Results: For SD-OCT measurements in healthy subjects, CoR1 and CoR2 were less than 5.00 and 5.53 mu m. ICC1 and ICC2 were more than 0.997 and 0.996. For SD-OCT measurements in LASIK patients, CoR1 and CoR2 were less than 5.09 and 5.34 mu m. ICC1 and ICC2 were more than 0.997 and 0.996. For SD-OCT measurements in keratoconus patients, CoR1 and CoR2 were less than 11.57 and 10.92 mu m. ICC1 and ICC2 were more than 0.995 and 0.996. Conclusions: The measurements of corneal pachymetric mapping by long scan depth SD-OCT can be assessed over the entire corneal area with good repeatability and reproducibility. (C) 2017 S. Karger AG, Basel
引用
收藏
页码:115 / 125
页数:11
相关论文
共 61 条
[21]   Pellucid corneal marginal degeneration: A review [J].
Jinabhai, Amit ;
Radhakrishnan, Hema ;
O'Donnell, Clare .
CONTACT LENS & ANTERIOR EYE, 2011, 34 (02) :56-63
[22]   Comparison of corneal thickness measurements using Orbscan II, non-contact specular microscopy, and ultrasonic pachymetry in eyes after laser in situ keratomileusis [J].
Kawana, K ;
Tokunaga, T ;
Miyata, K ;
Okamoto, F ;
Kiuchi, T ;
Oshika, T .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (04) :466-468
[23]   High-speed optical coherence tomography of corneal opacities [J].
Khurana, Rahul N. ;
Li, Yan ;
Tang, Maolong ;
Lai, Michael M. ;
Huang, David .
OPHTHALMOLOGY, 2007, 114 (07) :1278-1285
[24]  
KRACHMER JH, 1978, ARCH OPHTHALMOL-CHIC, V96, P1217
[25]   Robust automatic segmentation of corneal layer boundaries in SDOCT images using graph theory and dynamic programming [J].
LaRocca, Francesco ;
Chiu, Stephanie J. ;
McNabb, Ryan P. ;
Kuo, Anthony N. ;
Izatt, Joseph A. ;
Farsiu, Sina .
BIOMEDICAL OPTICS EXPRESS, 2011, 2 (06) :1524-1538
[26]   Corneal pachymetry mapping with high-speed optical coherence tomography [J].
Li, Y ;
Shekhar, R ;
Huang, D .
OPHTHALMOLOGY, 2006, 113 (05) :792-799
[27]   Corneal Epithelial Thickness Mapping by Fourier-Domain Optical Coherence Tomography in Normal and Keratoconic Eyes [J].
Li, Yan ;
Tan, Ou ;
Brass, Robert ;
Weiss, Jack L. ;
Huang, David .
OPHTHALMOLOGY, 2012, 119 (12) :2425-2433
[28]   Pachymetric mapping with Fourier-domain optical coherence tomography [J].
Li, Yan ;
Tang, Maolong ;
Zhang, Xinbo ;
Salaroli, Camila H. ;
Ramos, Jose L. ;
Huang, David .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (05) :826-831
[29]   Keratoconus Diagnosis with Optical Coherence Tomography Pachymetry Mapping [J].
Li, Yan ;
Meisler, David M. ;
Tang, Maolong ;
Lu, Ake T. H. ;
Thakrar, Vishakha ;
Reiser, Bibiana J. ;
Huang, David .
OPHTHALMOLOGY, 2008, 115 (12) :2159-2166
[30]   The repeatability of corneal thickness measures [J].
Marsich, MM ;
Bullimore, MA .
CORNEA, 2000, 19 (06) :792-795