Reliability of Entire Corneal Thickness Mapping in Normal Post-Laser in situ Keratomileusis and Keratoconus Eyes Using Long Scan Depth Spectral Domain Optical Coherence Tomography

被引:4
作者
Xu, Zhe [1 ]
Chen, Sisi [1 ]
Yang, Chun [1 ]
Huang, Shenghai [1 ]
Shen, Meixiao [1 ]
Wang, Yuanyuan [1 ]
机构
[1] Wenzhou Med Univ, Sch Ophthalmol & Optometry, 270 Xueyuan Rd, Wenzhou 325027, Zhejiang, Peoples R China
基金
中国国家自然科学基金;
关键词
Entire corneal thickness mapping; Repeatability; Reproducibility; Long scan depth spectral domain optical coherence tomography; ANTERIOR SEGMENT; ULTRASONIC PACHYMETRY; HIGH-SPEED; AUTOMATIC SEGMENTATION; EPITHELIAL THICKNESS; BOWMANS LAYER; CONTACT-LENS; REPEATABILITY; REPRODUCIBILITY; RESOLUTION;
D O I
10.1159/000478985
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the repeatability and reproducibility of mapping the entire corneal thickness using spectral domain optical coherence tomography (SD-OCT). Methods: Thirty normal eyes, 30 post-laser in situ keratomileusis (LASIK) surgery eyes, and 30 keratoconus eyes were analyzed. A custom-built long scan depth SD-OCT device was used to obtain entire corneal images. Ten-millimeter-diameter corneal thickness maps were generated by an automated segmentation algorithm. Intraclass correlation coefficients of repeatability (ICC1) and reproducibility (ICC2), and coefficients of repeatability (CoR1) and reproducibility (CoR2), were calculated to quantify the precision and accuracy of corneal pachymetry measurements using the Bland-Altman method. Results: For SD-OCT measurements in healthy subjects, CoR1 and CoR2 were less than 5.00 and 5.53 mu m. ICC1 and ICC2 were more than 0.997 and 0.996. For SD-OCT measurements in LASIK patients, CoR1 and CoR2 were less than 5.09 and 5.34 mu m. ICC1 and ICC2 were more than 0.997 and 0.996. For SD-OCT measurements in keratoconus patients, CoR1 and CoR2 were less than 11.57 and 10.92 mu m. ICC1 and ICC2 were more than 0.995 and 0.996. Conclusions: The measurements of corneal pachymetric mapping by long scan depth SD-OCT can be assessed over the entire corneal area with good repeatability and reproducibility. (C) 2017 S. Karger AG, Basel
引用
收藏
页码:115 / 125
页数:11
相关论文
共 61 条
  • [1] Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry
    Barkana, Y
    Gerber, Y
    Elbaz, U
    Schwartz, S
    Ken-Dror, G
    Avni, I
    Zadok, D
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (09) : 1729 - 1735
  • [2] INTRACLASS CORRELATION COEFFICIENT AS A MEASURE OF RELIABILITY
    BARTKO, JJ
    [J]. PSYCHOLOGICAL REPORTS, 1966, 19 (01) : 3 - &
  • [3] Central corneal thickness measurement with a retinal optical coherence tomography device versus standard ultrasonic pachymetry
    Bechmann, M
    Thiel, MJ
    Neubauer, AS
    Ullrich, S
    Ludwig, K
    Kenyon, KR
    Ulbig, MW
    [J]. CORNEA, 2001, 20 (01) : 50 - 54
  • [4] Bland JM, 1996, BRIT MED J, V313, P744
  • [5] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [6] Central corneal thickness and measured IOP response to topical ocular hypotensive medication in the ocular hypertension treatment study
    Brandt, JD
    Beiser, JA
    Gordon, MO
    Kass, MA
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2004, 138 (05) : 717 - 722
  • [7] Central and Peripheral Corneal Thinning in Keratoconus
    Brautaset, Rune L.
    Nilsson, Maria
    Miller, William L.
    Leach, Norman E.
    Tukler, Johanna H.
    Bergmanson, Jan P. G.
    [J]. CORNEA, 2013, 32 (03) : 257 - 261
  • [8] Automatic segmentation of seven retinal layers in SDOCT images congruent with expert manual segmentation
    Chiu, Stephanie J.
    Li, Xiao T.
    Nicholas, Peter
    Toth, Cynthia A.
    Izatt, Joseph A.
    Farsiu, Sina
    [J]. OPTICS EXPRESS, 2010, 18 (18): : 19413 - 19428
  • [9] In vivo corneal high-speed, ultra-high-resolution optical coherence tomography
    Christopoulos, Viki
    Kagemann, Larry
    Wollstein, Gadi
    Ishikawa, Hi. Roshi
    Gabriele, Michelle L.
    Wojtkowski, Maciej
    Srinivasan, Vivek
    Fujimoto, James G.
    Duker, Jay S.
    Dhaliwal, Deepinder K.
    Schuman, Joel S.
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2007, 125 (08) : 1027 - 1035
  • [10] Corneal Thickness in Keratoconus Comparing Optical, Ultrasound, and Optical Coherence Tomography Pachymetry
    Dutta, Debarun
    Rao, Harsha L.
    Addepalli, Uday K.
    Vaddavalli, Pravin K.
    [J]. OPHTHALMOLOGY, 2013, 120 (03) : 457 - 463