Combining electrical resistance and 3-D X-ray computed tomography for moisture distribution measurements in wood products exposed in dynamic moisture conditions

被引:25
作者
Li, Wanzhao [1 ,2 ]
Van den Bulcke, Jan [1 ,2 ]
De Windt, Imke [1 ,2 ]
Van Loo, Denis [2 ]
Dierick, Manuel [2 ,3 ]
Brabant, Loes [2 ,3 ]
Van Acker, Joris [1 ,2 ]
机构
[1] Univ Ghent, Fac Biosci Engn, Dept Forest & Water Management, B-9000 Ghent, Belgium
[2] Univ Ghent, UGCT, Ctr Xray Tomog, B-9000 Ghent, Belgium
[3] Univ Ghent, Inst Nucl Sci, Dept Phys & Astron, B-9000 Ghent, Belgium
关键词
Electrical resistance; X-ray computed tomography; Moisture content; Wood structure; RADIATA D. DON; WATER; QUANTIFICATION; ABSORPTION; MOVEMENT;
D O I
10.1016/j.buildenv.2013.05.026
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Strength and durability of wood-based products are substantially influenced by moisture. It is, therefore, crucial to monitor the moisture content (MC) distribution in wood products to fully understand their behaviour in dynamic moisture conditions. In this paper, we present a combined X-ray CT method and an adapted version of the electrical resistance MC measurement method for detailed studies on MC distribution in wood products. The X-ray CT method is evaluated using the gravimetrically recorded MC of solid wood. Subsequently, the recorded MC of electrical method is evaluated by using X-ray CT method. Three wood products are used for this purpose, i.e. solid wood, plywood and oriented strand board (OSB) panels. It is proven that X-ray CT method can accurately determine the MC of wood products and thus has great potential for non-destructively measuring the MC distribution in 3D. Furthermore, the results show that electrical method can effectively record the local MC when the MC distribution in this region is even. Otherwise, the position of the electrodes, with regard to specific wood properties has a substantial influence on its performance. Compared with solid wood and OSB, the electrical method performs best in plywood due to its layered structure. The adapted electrical method is an effective tool for continuously monitoring the MC distribution of wood products, taking into account that the electrodes are installed correctly according to the structure of the material and research questions. Combined with X-ray CT scanning, MC distribution of wood-based products under in-service applications, can be monitored. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:250 / 259
页数:10
相关论文
共 25 条
[1]   Three-Dimensional Analysis of High-Resolution X-Ray Computed Tomography Data with Morpho+ [J].
Brabant, Loes ;
Vlassenbroeck, Jelle ;
De Witte, Yoni ;
Cnudde, Veerle ;
Boone, Matthieu N. ;
Dewanckele, Jan ;
Van Hoorebeke, Luc .
MICROSCOPY AND MICROANALYSIS, 2011, 17 (02) :252-263
[2]   Monitoring the "material climate" of wood to predict the potential for decay: Results from in situ measurements on buildings [J].
Brischke, Christian ;
Rapp, Andreas Otto ;
Bayerbach, Rolf ;
Morsing, Niels ;
Fynholm, Peder ;
Welzbacher, Christian Robert .
BUILDING AND ENVIRONMENT, 2008, 43 (10) :1575-1582
[3]   Measurement system for long-term recording of wood moisture content with internal conductively glued electrodes [J].
Brischke, Christian ;
Rapp, Andreas Otto ;
Bayerbach, Rolf .
BUILDING AND ENVIRONMENT, 2008, 43 (10) :1566-1574
[4]   Digital X-ray analysis of density distribution characteristics of wood-based panels [J].
Chen, Siguo ;
Liu, Xiaohong ;
Fang, Luming ;
Wellwood, Robert .
WOOD SCIENCE AND TECHNOLOGY, 2010, 44 (01) :85-93
[5]   High-resolution proxies for wood density variations in Terminalia superba [J].
De Ridder, Maaike ;
Van den Bulcke, Jan ;
Vansteenkiste, Dries ;
Van Loo, Denis ;
Dierick, Manuel ;
Masschaele, Bert ;
De Witte, Yoni ;
Mannes, David ;
Lehmann, Eberhard ;
Beeckman, Hans ;
Van Hoorebeke, Luc ;
Van Acker, Joris .
ANNALS OF BOTANY, 2011, 107 (02) :293-302
[6]   A LabVIEW® based generic CT scanner control software platform [J].
Dierick, M. ;
Van Loo, D. ;
Masschaele, B. ;
Boone, M. ;
Van Hoorebeke, L. .
JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2010, 18 (04) :451-461
[7]  
GERHARDS CC, 1982, WOOD FIBER SCI, V14, P4
[8]  
Haygreen J.G., 1996, FOREST PRODUCTS WOOD, V3rd
[9]   MEDICAL CAT-SCANNING - X-RAY ABSORPTION-COEFFICIENTS, CT-NUMBERS AND THEIR RELATION TO WOOD DENSITY [J].
LINDGREN, LO .
WOOD SCIENCE AND TECHNOLOGY, 1991, 25 (05) :341-349
[10]   Moisture content in timber decking exposed to bushfire weather conditions [J].
Macindoe, Lyndon ;
Leonard, Justin .
FIRE AND MATERIALS, 2012, 36 (01) :49-61