Development of the loop-mediated isothermal amplification method for rapid detection of cytomegalovirus DNA

被引:25
作者
Suzuki, R
Yoshikawa, T [1 ]
Ihira, M
Enomoto, Y
Inagaki, S
Matsumoto, K
Kato, K
Kudo, K
Kojima, S
Asano, Y
机构
[1] Fujita Hlth Univ, Sch Med, Dept Pediat, Toyoake, Aichi 4701192, Japan
[2] Fujita Hlth Univ Hosp, Div Pharm, Toyoake, Aichi, Japan
[3] Fujita Hlth Univ Coll, Dept Med Informat Technol, Toyoake, Aichi, Japan
[4] Japanese Red Cross Nagoya First Hosp, Childrens Med Ctr, Div Hematol Oncol, Nagoya, Aichi, Japan
[5] Nagoya Univ, Grad Sch Med, Dept Pediat Dev Pediat, Nagoya, Aichi, Japan
关键词
CMV; LAMP; real-time PCR; immunocompromised patient;
D O I
10.1016/j.jviromet.2005.09.008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Cytomegalovirus (CMV) loop-mediated isothermal amplification (LAMP) was performed on DNA extracted from CMV (AD-169)-, herpes simplex virus (HSV) 1 (KOS)-, HSV-2 (186), varicella-zoster virus (Oka-vaccine)-, human herpesvirus (HHV)-6 A (U1102)-, HHV-6 B (Z29)-, and HHV-7 (RK)-infected cells. Although amplified CMV demonstrated typical ladder patterns, no LAMP product was detected in reactions performed with other viral DNAs. The sensitivity of the CMV LAMP was 500 copies/tube, as determined by either agarose gel electrophoresis or turbidity assay. To determine whether CMV LAMP could be used for quantitative analysis of viral DNA, threshold times, defined as the time (in seconds) to reach the threshold level (0.1), were measured by amplification of serial dilutions of the plasmid DNA. The standard curve exhibited a correlation coefficient of 0.944, a slope of -208.1, and a y-intercept of 3261.4. Following these initial validation experiments, we analyzed 180 samples collected serially from 20 pediatric hematopoietic stem cell transplant recipients. Detection of CMV DNA in whole blood (WB) was tested by CMV LAMP and real-time polymerase chain reaction (PCR). When > 500 copies/tube (> 5000 copies/200 mu l of WB) was defined as positive for CMV infection, the sensitivity, specificity, positive predictive value, and negative predictive values of the CMV LAMP were 80.0, 98.9, 66.7, and 99.4%, respectively. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:216 / 221
页数:6
相关论文
共 27 条
[1]   Optimization of quantitative detection of cytomegalovirus DNA in plasma by real-time PCR [J].
Boeckh, M ;
Huang, M ;
Ferrenberg, J ;
Stevens-Ayers, T ;
Stensland, L ;
Nichols, WG ;
Corey, L .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (03) :1142-1148
[2]   Clinical trial of quantitative real-time polymerase chain reaction for detection of cytomegalovirus in peripheral blood of allogeneic hematopoietic stem-cell transplant recipients [J].
Cortez, KJ ;
Fischer, SH ;
Fahle, GA ;
Calhoun, LB ;
Childs, RW ;
Barrett, AJ ;
Bennett, JE .
JOURNAL OF INFECTIOUS DISEASES, 2003, 188 (07) :967-972
[3]   Rapid diagnosis of herpes simplex virus infection by a loop-mediated isothermal amplification method [J].
Enomoto, Y ;
Yoshikawa, T ;
Ihira, M ;
Akimoto, S ;
Miyake, F ;
Usui, C ;
Suga, S ;
Suzuki, K ;
Kawana, T ;
Nishiyama, Y ;
Asano, Y .
JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (02) :951-955
[4]   Quantification of human cytomegalovirus DNA in bone marrow transplant recipients by real-time PCR [J].
Griscelli, F ;
Barrois, M ;
Chauvin, S ;
Lastere, S ;
Bellet, D ;
Bourhis, JH .
JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (12) :4362-4369
[5]   Sensitive and specific detection of Yersinia pseudotuberculosis by loop-mediated isothermal amplification [J].
Horisaka, T ;
Fujita, K ;
Iwata, T ;
Nakadai, A ;
Okatani, AT ;
Horikita, T ;
Taniguchi, T ;
Honda, E ;
Yokomizo, Y ;
Hayashidani, H .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (11) :5349-5352
[6]   Rapid diagnosis of human herpesvirus 6 infection by a novel DNA amplification method, loop-mediated isothermal amplification [J].
Ihira, M ;
Yoshikawa, T ;
Enomoto, Y ;
Akimoto, S ;
Ohashi, M ;
Suga, S ;
Nishimura, N ;
Ozaki, T ;
Nishiyama, Y ;
Notomi, T ;
Ohta, Y ;
Asano, Y .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (01) :140-145
[7]   Loop-mediated isothermal amplification for direct detection of Mycobacterium tuberculosis complex, M-avium, and M-intracellulare in sputum samples [J].
Iwamoto, T ;
Sonobe, T ;
Hayashi, K .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (06) :2616-2622
[8]   Validation of clinical application of cytomegalovirus plasma DNA load measurement and definition of treatment criteria by analysis of correlation to antigen detection [J].
Kalpoe, JS ;
Kroes, ACM ;
de Jong, MD ;
Schinkel, J ;
de Brouwer, CS ;
Beersma, MFC ;
Claas, ECJ .
JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (04) :1498-1504
[9]   Loop-mediated isothermal amplification for detection of African trypanosomes [J].
Kuboki, N ;
Inoue, N ;
Sakurai, T ;
Di Cello, F ;
Grab, DJ ;
Suzuki, H ;
Sugimoto, C ;
Igarashi, I .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (12) :5517-5524
[10]   Monitoring cytomegalovirus infection in adult and pediatric bone marrow transplant recipients by a real-time PCR assay performed with blood plasma [J].
Leruez-Ville, M ;
Ouachée, M ;
Delarue, R ;
Sauget, AS ;
Blanche, S ;
Buzyn, A ;
Rouzioux, C .
JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (05) :2040-2046