EAF Heat Recovery from Incident Radiation on Water-Cooled Panels Using a Thermophotovoltaic System: A Conceptual Study

被引:5
作者
Saboohi, Yadollah [1 ]
Fathi, Amorhossein [1 ]
Skrjanc, Igor [2 ]
Logar, Vito [2 ]
机构
[1] Sharif Univ Technol, SERI, Azadi Ave, Tehran 1459777611, Iran
[2] Univ Ljubljana, Lab Modelling Simulat & Control LMSV, Fac Elect Engn, Trzaska 25, SI-1000 Ljubljana, Slovenia
关键词
Electric arc furnace; Heat recovery; Radiative heat transfer; Thermophotovoltaic system; Water-cooled panels; ARC; EXERGY;
D O I
10.1002/srin.201700446
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
In this paper, a conceptual study and quantification of using a thermophotovoltaic system (TPV) to convert incident radiation on furnace panels to electrical energy is presented. In typical electric arc furnaces (EAF), a considerable amount of energy is wasted during the melting process, that is, steel enthalpy, off-gas extraction, vessel cooling, slag enthalpy, and others. Although a remarkable share of the energy is wasted in circulating water, the contained exergy is simply too low to be considered for heat recovery (under 0.5% of input exergy) in comparison to energy content of the extracted gasses and slag. In the performed study, a TPV power output is calculated as a function of arc length, slag and bath height, zone temperatures, and emissivities. Two major changes to the existent EAF model were performed in order to estimate the TPV efficiency, that is, 1) the radiative heat transfer module has been re-developed to allow calculation of the incident radiation on the TPV, 2) the model has been extended with a TPV module, which is used to estimate the electricity produced by the TPV. The effects of TPV capacity, its distance from the slag layer and input regime on generated electrical energy are studied. The results have shown that a typical EAF, equipped with TPV system, can reduce average energy consumption by 4.8kWh ton(-1), which corresponds to approximately 0.8% overall efficiency improvement. Moreover, the capacity factor of the installed TPV is predicted at 54% over a period of one year.
引用
收藏
页数:8
相关论文
共 31 条
[1]  
[Anonymous], 5 C THERM
[2]  
[Anonymous], 2012, REV DES ENERGIES REN
[3]  
Bauer T., 2004, International Journal of Ambient Energy, V25, P19, DOI 10.1080/01430750.2004.9674933
[4]   Thermophotovoltaics: Basic principles and critical aspects of system design [J].
Bauer T. .
Green Energy and Technology, 2011, 7
[5]   Exergy analysis and efficiency in an industrial AC electric ARC furnace [J].
Çamdali, Ü ;
Tunç, M .
APPLIED THERMAL ENGINEERING, 2003, 23 (17) :2255-2267
[6]  
Chubb D.L., 2007, Fundamentals of Thermophotovoltaic Energy Conversion
[7]  
Cole Wesley., 2016, 2016 Standard Scenarios Report: A U.S. Electricity Sector Outlook
[8]   Comprehensive Electric Arc Furnace Model for Simulation Purposes and Model-Based Control [J].
Fathi, Amirhossein ;
Saboohi, Yadollah ;
Skrjanc, Igor ;
Logar, Vito .
STEEL RESEARCH INTERNATIONAL, 2017, 88 (03)
[9]   Low Computational-complexity Model of EAF Arc-heat Distribution [J].
Fathi, Amirhossein ;
Saboohi, Yadollah ;
Skrjanc, Igor ;
Logar, Vito .
ISIJ INTERNATIONAL, 2015, 55 (07) :1353-1360
[10]   Overview and Status of Thermophotovoltaic Systems [J].
Ferrari, C. ;
Melino, F. ;
Pinelli, M. ;
Spina, P. R. ;
Venturini, M. .
ATI 2013 - 68TH CONFERENCE OF THE ITALIAN THERMAL MACHINES ENGINEERING ASSOCIATION, 2014, 45 :160-169