Eye injury from electrical weapon probes: Mechanisms and treatment

被引:8
作者
Kroll, Mark W. [1 ,7 ]
Ritter, Mollie B. [2 ]
Kennedy, Eric A. [3 ]
Siegal, Nora K. [4 ]
Shinder, Roman [4 ]
Brave, Michael A. [5 ]
Williams, Howard E. [6 ]
机构
[1] Univ Minnesota, Biomed Engn, Minneapolis, MN 55455 USA
[2] Piedmont Hlth Syst, Atlanta, GA USA
[3] Bucknell Univ, Biomed Engn, Lewisburg, PA 17837 USA
[4] Suny Downstate Med Ctr, Dept Ophthalmol, Brooklyn, NY 11203 USA
[5] LAAW Int LLC, Washington, DC USA
[6] Texas State Univ, Sch Criminal Justice, San Marcos, TX USA
[7] Calif Polytech Inst, San Luis Obispo, CA USA
关键词
Blind; CEW; ECD; Electrical weapon; Eye injury; TASER; ELECTRONIC-CONTROL-DEVICES; POLICE USE; CATARACT; RISK;
D O I
10.1016/j.ajem.2018.06.004
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Purpose: While generally reducing morbidity and mortality, TASER (R) electrical weapons have risks associated with their usage, including burn injuries and head and cervical trauma associated with uncontrolled falls. The primary non-fatal complications appear to be significant eye injury but no analysis of the mechanisms or suggested treatments has been published. Methods: We used a biomechanical model to predict the risk of eye injury as a function of distance from the weapon muzzle to the eye. We compared our model results to recently published epidemiological findings. We also describe the typical presentation and suggest treatment options. Results: The globe rupture model predicted that a globe rupture can be expected (50% risk) when the eye is within 6 m of the muzzle and decreases rapidly beyond that. This critical distance is 9 m for lens and retinal damage which is approximately the range of the most common probe cartridges. Beyond 9 m, hyphema is expected along with a perforation by the dart portion of the probe. Our prediction of globe rupture out to 6 m (out of a typical range of 9 m) is consistent with the published risk of enucleation or unilateral blindness being 69 +/- 18%, with an eye penetration. Conclusions: Significant eye injury is expected from a penetration by an electrical weapon probe at dose range. The risk decreases rapidly at extended distances from the muzzle. Not all penetrating globe injuries from electrical weapon probes will result in blindness. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:427 / 432
页数:6
相关论文
共 39 条
  • [1] ELECTRICAL INJURY OF THE EYE
    ALRABIAH, SMH
    ARCHER, DB
    MILLAR, R
    COLLINS, AD
    SHEPHERD, WFI
    [J]. INTERNATIONAL OPHTHALMOLOGY, 1987, 11 (01) : 31 - 40
  • [2] BOOZALIS G T, 1991, Journal of Burn Care and Rehabilitation, V12, P458, DOI 10.1097/00004630-199109000-00012
  • [3] Brozoski F, 2011, FINAL REPORT EYE INJ
  • [4] Cahill C., 2015, AUSTIN J CLIN OPHTHA, V2, P1
  • [5] Perforating ocular injury by Taser
    Chen, SL
    Richard, CK
    Murthy, RC
    Lauer, AK
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2006, 34 (04) : 378 - 380
  • [6] The ignitability of petrol vapours and potential for vapour phase explosion by use of TASER® law enforcement electronic control device
    Clarke, C.
    Andrews, S. P.
    [J]. SCIENCE & JUSTICE, 2014, 54 (06) : 412 - 420
  • [7] Electrical Characteristics of an Electronic Control Device Under a Physiologic Load: A Brief Report
    Dawes, Donald M.
    Ho, Jeffrey D.
    Kroll, Mark W.
    Miner, James R.
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (03): : 330 - 336
  • [8] Determination of significant parameters for eye injury risk from projectiles
    Duma, SM
    Ng, TP
    Kennedy, EA
    Stitzel, JD
    Herring, IP
    Kahn, F
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 59 (04) : 960 - 964
  • [9] The Influence of Agency Policies on Conducted Energy Device Use and Police Use of Lethal Force
    Ferdik, Frank V.
    Kaminski, Robert J.
    Cooney, Mikaela D.
    Sevigny, Eric L.
    [J]. POLICE QUARTERLY, 2014, 17 (04) : 328 - 358
  • [10] In Silico Estimates of Cell Electroporation by Electrical Incapacitation Waveforms
    Gowrishankar, T. R.
    Esser, A. T.
    Smith, K. C.
    Burns, S. K.
    Weaver, J. C.
    [J]. 2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 6505 - 6508