Effect of Distal Implant Inclination on Dislodging Forces of Different Locator Attachments Used for Mandibular Overdentures: An In Vitro Study

被引:25
作者
ELsyad, Moustafa Abdou [1 ]
Emera, Radwa Mohsen [1 ]
Ashmawy, Tarek Mohy [2 ]
机构
[1] Univ Mansoura, Dept Removable Prosthodont, Fac Dent, POB 35516,68 ElGomhoria St, Eldakahlia, Elmansoura, Egypt
[2] Cairo Univ, Natl Canc Inst, Dept Maxillofacial Prosthodont, Cairo, Egypt
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2019年 / 28卷 / 02期
关键词
Attachment; implant inclinations; Locator; overdenture; retention; PERI-IMPLANT; SUPPORTED OVERDENTURES; 2-IMPLANT OVERDENTURES; RETENTION FORCES; ANGULATION; STABILITY; SYSTEMS; WEAR; STRAIN;
D O I
10.1111/jopr.12710
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose To evaluate the effect of distal implant inclination on axial and nonaxial retentive forces of different Locator attachments used to retain mandibular overdentures. Materials and methods Four duplicate mandibular edentulous acrylic models received 2 implants in the canine areas with 0 degrees, 5 degrees, 10 degrees, and 20 degrees distal inclinations. Experimental overdentures were connected to the implants with Locator extra light retention (Le), Locator light retention (Ll), and Locator medium retention (Lm). For the 20 degrees model, extended range Locator extra-light retention (Lee) and Locator medium retention (Lem) were used. Axial and nonaxial (anterior, posterior, lateral) retentive forces were measured initially and after 540 cycles of denture insertion and removal. Three-way mixed ANOVA was used to analyze axial and nonaxial retentive forces Results After wear simulation, 20 degrees angulation showed the highest axial retention for Le and Ll while 5 degrees showed the highest retention for Lm; 0 degrees and 5 degrees showed the highest anterior and posterior retention for Lm; 20 degrees showed the highest lateral retention for Le and Ll. For all implant inclinations, Lm showed the highest axial and nonaxial retention, and Le and Lee showed the lowest retention for 10 degrees and 20 degrees inclined implants, respectively. Conclusions Axial and nonaxial retention of Locator attachments for implant-retained overdentures are significantly affected by the degree of distal implant inclination and the type of nylon inserts. Lm is recommended to retain overdentures when implants have 5 degrees or 10 degrees distal inclination, and Le and Ll are recommended with 20 degrees inclination to maintain high axial and nonaxial retention after wear.
引用
收藏
页码:E666 / E674
页数:9
相关论文
共 39 条
[1]   RETENTIVE CHARACTERISTICS OF DIFFERENT DENTAL MAGNETIC SYSTEMS [J].
AKALTAN, F ;
CAN, G .
JOURNAL OF PROSTHETIC DENTISTRY, 1995, 74 (04) :422-427
[2]   THE IN VITRO EFFECT OF DIFFERENT IMPLANT ANGULATIONS AND CYCLIC DISLODGEMENT ON THE RETENTIVE PROPERTIES OF AN OVERDENTURE ATTACHMENT SYSTEM [J].
Al-Ghafli, Suhail Ali ;
Michalakis, Konstantinos X. ;
Hirayama, Hiroshi ;
Kang, Kiho .
JOURNAL OF PROSTHETIC DENTISTRY, 2009, 102 (03) :140-147
[3]   Retention force and fatigue strength of overdenture attachment systems [J].
Botega, DM ;
Mesquita, MF ;
Henriques, GEP ;
Vaz, LG .
JOURNAL OF ORAL REHABILITATION, 2004, 31 (09) :884-889
[4]   Locators versus magnetic attachment effect on peri-implant tissue health of immediate loaded two implants retaining a mandibular overdenture: a 1-year randomised trial [J].
Elsyad, M. A. ;
Mahanna, F. F. ;
Elshahat, M. A. ;
Elshoukouki, A. H. .
JOURNAL OF ORAL REHABILITATION, 2016, 43 (04) :297-305
[5]   Peri-implant strain around mesially inclined two-implant-retained mandibular overdentures with Locator attachments [J].
Elsyad, Moustafa A. ;
Eltowery, Salem M. ;
Gebreel, Ashraf A. .
JOURNAL OF ORAL SCIENCE, 2017, 59 (04) :483-490
[6]   Effect of two designs of implant-supported overdentures on peri-implant and posterior mandibular bone resorptions: a 5-year prospective radiographic study [J].
Elsyad, Moustafa A. ;
Alokda, Mohammed Mahmoud ;
Gebreel, Ashraf Anwer ;
Hammouda, Nelly Ibrahim ;
Habib, Ahmed Ali .
CLINICAL ORAL IMPLANTS RESEARCH, 2017, 28 (10) :E184-E192
[7]   Retentive Properties of O-Ring and Locator Attachments for Implant-Retained Maxillary Overdentures: An In Vitro Study [J].
ELsyad, Moustafa Abdou ;
Elhaddad, Abdelsalam Amohamed ;
Khirallah, Ahmed Samir .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (06) :568-576
[8]   Effect of Buccal Implant Inclination on Stresses Around Two-Implant-Retained Overdentures with Resilient Stud Attachments [J].
Elsyad, Moustafa Abdou ;
Abid, Karima Salah ;
Abd Elkhalek, Elsayed .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (03) :E135-E142
[9]   Retention and Stability of Implant-Retained Mandibular Overdentures Using Different Types of Resilient Attachments: An In Vitro Study [J].
ELsyad, Moustafa Abdou ;
Agha, Nora Nory ;
Habib, Ahmed Ali .
INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (05) :1040-1048
[10]   Mandibular Denture Base Deformation with Locator and Ball Attachments of Implant-Retained Overdentures [J].
ELsyad, Moustafa Abdou ;
Errabti, Hatem Mokhtar ;
Mustafa, Aisha Zakaria .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2016, 25 (08) :656-664