Right pectoral implantable cardioverter defibrillators: role of the proximal (SVC) coil

被引:14
作者
Varma, Niraj
Efimov, Igor
机构
[1] Univ Hosp Cleveland, Cleveland, OH 44106 USA
[2] Case Western Reserve Univ, Cleveland, OH 44106 USA
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2008年 / 31卷 / 08期
关键词
ICD; DFT; right-sided; shock waveform; impedance; phase duration;
D O I
10.1111/j.1540-8159.2008.01130.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Increased defibrillation thresholds (DFTs) with right active pectoral implantable cardioverter defibrillators (ICDs) and/or right proximal coils (SVC) ore attributed to poorer vector. However, SVC affects impedance, current flow, and shock waveform phase duration (PD), which exert independent DFT effects. Objective: Compare DFTs and shock characteristics in SVC On with SVC Off in right ICDs. Methods and Results: DFT+ testing (n = 42, 62% males, 62 +/- 15 years, left ventricular ejection fraction (LVEF) 26 +/- 11 %, ischemic cardiomyopathy 65%, amiodarone 26%) revealed > 20% incidence of high DFT (> 20J). Dilated cardiomyopathy and amiodarone increased DFT Individual impedance variability (25-74 Omega) generated a wide PD range (2.6-8.7 ms). Overall, SVC On reduced impedance by 33% (from 54 +/- 10 to 35 +/- 5 Omega, P < 0.0001), and shortened PD (from 5.45 +/- 1.20 to 3.67 +/- 0.74 ms, P < 0.01). SVC On affected DFTs in 19/42 (45%) patients. SVC On was beneficial in 12/19. PD shortened but current flow remained unaltered. (In these, SVC Off impedance was > 45 Omega and PD > 5 ms.) SVC On was detrimental in 7/19 despite increasing current flow. In these, PD shortened excessively (median 2.9 ms) because impedance was low (31 +/- 4 Omega). In 3/6 cases with DFTs > 20 J in both SVC On and Off, PD optimization reduced DFT Overall, selection of best SVC configuration or deliberate PD programming yielded DFTs <= 20 J in > 90% patients, reducing need for system modification to < 7%. Conclusions: Right pectoral active ICDs have high DFTs. The SVC coil may be detrimental when pulse waveform excessively shortens. Noninvasive maneuvers, for example, SVC and waveform optimization, may improve DFT.
引用
收藏
页码:1025 / 1035
页数:11
相关论文
共 37 条
[1]   The defibrillation safety margin of patients receiving ICDs: A matter of definition [J].
Barold, SS ;
Herweg, B ;
Curtis, AB .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (09) :881-882
[2]   Mechanisms of shock-induced arrhythmogenesis during acute global ischemia [J].
Cheng, Y ;
Mowrey, KA ;
Nikolski, V ;
Tchou, PJ ;
Efimov, IR .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2002, 282 (06) :H2141-H2151
[3]   Benefit of millisecond waveform durations for patients with high defibrillation thresholds [J].
Denman, Russell A. ;
Umesan, Chirammal ;
Martin, Paul T. ;
Forbes, Ross N. ;
Kroll, Mark W. ;
Anskey, Emma J. ;
Burnett, Helen E. .
HEART RHYTHM, 2006, 3 (05) :536-541
[4]   DEFIBRILLATION CURRENT AND IMPEDANCE ARE DETERMINANTS OF DEFIBRILLATION ENERGY-REQUIREMENTS [J].
DORIAN, P ;
WANG, MJ .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (11) :1996-2001
[5]   ELEVATED DEFIBRILLATION THRESHOLD WHEN RIGHT-SIDED VENOUS ACCESS IS USED FOR NONTHORACOTOMY IMPLANTABLE DEFIBRILLATOR LEAD IMPLANTATION [J].
EPSTEIN, AE ;
KAY, GN ;
PLUMB, VJ ;
VOSHAGESTAHL, L ;
HULL, ML .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1995, 6 (11) :979-986
[6]   Comparison of right- and left-sided pectoral implantation parameters with the jewel active can cardiodefibrillator [J].
Flaker, GC ;
Tummala, R ;
Wilson, J .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (02) :447-451
[7]   Defibrillation thresholds are increased by right-sided implantation of totally transvenous implantable cardioverter defibrillators [J].
Friedman, PA ;
Rasmussen, MJ ;
Grice, S ;
Trusty, J ;
Glikson, M ;
Stanton, MS .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (08) :1186-1192
[8]   Optimization of superior vena cava coil position and usage for transvenous defibrillation [J].
Gold, Michael ;
VaL-Mejias, Jesus ;
Leman, Robert B. ;
Tummala, Rangarao ;
Goyal, Sanjeev ;
Kluger, Jeffrey ;
Kroll, Mark ;
Oza, Ashish .
HEART RHYTHM, 2008, 5 (03) :394-399
[9]  
Gold MR, 1997, CIRCULATION, V96, P3517
[10]   Optimization of transvenous coil position for active can defibrillation thresholds [J].
Gold, MR ;
Olsovsky, MR ;
Degroot, PJ ;
Cuello, C ;
Shorofsky, SR .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (01) :25-29