Rapid analysis of the in-process extract solutions of compound E Jiao oral liquid using near infrared spectroscopy and partial least-squares regression

被引:9
作者
Han, Haifan [1 ]
Zhang, Lu [2 ]
Zhang, Yan [2 ]
Li, Wenlong [1 ]
Qu, Haibin [1 ]
机构
[1] Zhejiang Univ, Coll Pharmaceut Sci, Pharmaceut Informat Inst, Hangzhou 310058, Zhejiang, Peoples R China
[2] Shandong Dong E E Jiao Co Ltd, Liaocheng 252299, Peoples R China
关键词
ANALYTICAL TECHNOLOGY PAT; NIR SPECTROSCOPY; MULTIVARIATE CALIBRATION; ALCOHOL PRECIPITATION; VARIABLE SELECTION; LONICERA-JAPONICA; OUTLIER DETECTION; CHEMOMETRICS; TOOL; VALIDATION;
D O I
10.1039/c3ay40989a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid and simultaneous quantification of the main active compounds of the in-process extract solutions is beneficial to the process monitoring as well as ensuring quality consistency of the end products during the production of traditional Chinese medicine. Here we present a near infrared (NIR) spectroscopy-based method for rapid analysis of extract solutions in the production of compound E Jiao oral liquid. The partial least-squares regression (PLSR) models for four quality indicators (viz. total flavonoids, total saponins, total saccharides and soluble solid contents) were established and validated. The results showed that all of the four models exhibited satisfactory fitting and predictive capacity. The root mean squares error of prediction (RMSEP) was 0.0384 mg mL(-1), 0.0154 mg mL(-1), 3.80 mg mL(-1) and 0.199% for total flavonoids, total saponins, total saccharides and soluble solid contents, respectively. This work here demonstrated that NIR spectroscopy coupled with PLSR calibration can offer a reliable and non-destructive alternative in the routine monitoring of the extraction process in the production of compound E Jiao oral liquid. The presented approach is expected to be equally applicable to the mixed decoction of other herbal medicines.
引用
收藏
页码:5272 / 5278
页数:7
相关论文
共 32 条
[1]   Application of spectra cross-correlation for Type II outliers screening during multivariate near-infrared spectroscopic analysis of whole blood [J].
Abookasis, David ;
Workman, Jerome J. .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2011, 107 (02) :303-311
[2]   NIR spectroscopy: a rapid-response analytical tool [J].
Blanco, M ;
Villarroya, I .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2002, 21 (04) :240-250
[3]  
Burns D.A., 2007, Handbook of near-infrared analysis
[4]   Analysis of berberine and total alkaloid content in Cortex Phellodendri by near infrared spectroscopy (NIRS) compared with high-performance liquid chromatography coupled with ultra-visible spectrometric detection [J].
Chan, Chi-On ;
Chu, Ching-Ching ;
Mok, Daniel Kam-Wah ;
Chau, Foo-Tim .
ANALYTICA CHIMICA ACTA, 2007, 592 (02) :121-131
[5]   Quantitative analysis of triterpenoids in different parts of Ilex hainanensis, Ilex stewardii and Ilex pubescens using HPLC-ELSD and HPLC-MSn and antibacterial activity [J].
Chen, Xiao-Qing ;
Zan, Ke ;
Yang, Jie ;
Liu, Xiao-Xiao ;
Mao, Qian ;
Zhang, Li ;
Lai, Mao-Xiang ;
Wang, Qiang .
FOOD CHEMISTRY, 2011, 126 (03) :1454-1459
[6]   Quantification of total polysaccharides and triterpenoids in Ganoderma lucidum and Ganoderma atrum by near infrared spectroscopy and chemometrics [J].
Chen, Yi ;
Xie, Mingyong ;
Zhang, Hui ;
Wang, Yuanxing ;
Nie, Shaoping ;
Li, Chang .
FOOD CHEMISTRY, 2012, 135 (01) :268-275
[7]   Performance of some variable selection methods when multicollinearity is present [J].
Chong, IG ;
Jun, CH .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2005, 78 (1-2) :103-112
[8]   Avoiding pitfalls with chemometrics and PAT in the pharmaceutical and biotech industries [J].
Doherty, Steven J. ;
Lange, Andrew J. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2006, 25 (11) :1097-1102
[9]   How to avoid over-fitting in multivariate calibration -: The conventional validation approach and an alternative [J].
Faber, N. M. ;
Rajko, R. .
ANALYTICA CHIMICA ACTA, 2007, 595 (1-2) :98-106
[10]   A method for calibration and validation subset partitioning [J].
Galvao, RKH ;
Araujo, MCU ;
José, GE ;
Pontes, MJC ;
Silva, EC ;
Saldanha, TCB .
TALANTA, 2005, 67 (04) :736-740