Retinal Pigment Epithelium Cell Density and Bruch's Membrane Thickness in Secondary versus Primary High Myopia and Emmetropia

被引:13
作者
Jonas, Jost B. [1 ]
Li, Dong [2 ]
Holbach, Leonard [3 ]
Panda-Jonas, Songhomitra [4 ]
机构
[1] Heidelberg Univ, Med Fac Mannheim, Dept Ophthalmol, Mannheim, Germany
[2] Capital Med Univ, Beijing Key Lab Intraocular Tumor Diag & Treatmen, Beijing Ophthalmol & Visual Sci Key Lab, Beijing Tongren Eye Ctr,Beijing Tongren Hosp, Beijing, Peoples R China
[3] Friedrich Alexander Univ Erlangen Nurnberg, Dept Ophthalmol, Erlangen, Germany
[4] Augenpraxis Jonas, Heidelberg, Germany
关键词
AXIAL LENGTH;
D O I
10.1038/s41598-020-62096-7
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
To assess differences between secondary high myopia (SHM) due to congenital glaucoma and primary high myopia (PHM) and non-highly myopic eyes (NHM) in the relationships between axial length and Bruch's membrane (BM) thickness and retinal pigment epithelium (RPE) density. The histomorphometric study included human globes enucleated for reasons such as malignant uveal melanoma, end-stage painful secondary angle-closure glaucoma and congenital glaucoma. BM thickness and RPE cell density were measured upon light microscopy. The investigation included 122 eyes (mean axial length: 26.7 +/- 3.7 mm; range: 20.0-37.0 mm): 7 eyes with SHM (axial length: 33.7 +/- 2.1 mm; range: 31.0-37.0 mm), 56 eyes with PHM (mean axial length: 29.1 +/- 2.4 mm; range: 26.0-36.0 mm) and 59 eyes in the NHM-group (axial length: 23.5 +/- 1.3 mm; range: 20.0-25.5 mm). In the SHM group, longer axial length was associated with lower RPE cell density at the posterior pole (standardized regression coefficient beta: 0.92; non-standardized regression coefficient B: -2.76; 95% confidence interval (CI): -4.41, -1.10;P = 0.01), at the midpoint posterior pole/equator (beta: -0.87; B: -3.60; 95% CI: -6.48, -0.73;P = 0.03), and at the equator (beta: -0.88; B: -0.95; 95% CI: -1.68, -0.23; P = 0.02), but not at the ora serrata (P = 0.88). In the PHM-group and NHM group, RPE cell density at the posterior pole (P = 0.08) and ora serrata (P = 0.88) was statistically independent of axial length, while at the midpoint posterior pole/equator (P = 0.01) and equator (P < 0.001), RPE cell density decreased with longer axis. BM thickness in the SHM group decreased with longer axial length at the posterior pole (beta: -0.93;B: -0.29; 95% CI: -0.39, -0.14; P = 0.003), midpoint posterior pole/equator (beta: -0.79; B: -0.22; 95% CI: -0.42, -0.02; P = 0.035) and equator (beta: -0.84; B: -0.21; 95% CI: -0.37, -0.06; P = 0.017), while in the PHM-group and NHM-group, BM thickness at any ocular region was not statistically significantly correlated with axial length (all P > 0.05). In the SHM-group, but not in the PHM-group or NHM-group (P = 0.98), lower BM thickness was associated with lower RPE cell density (beta: 0.93; B: 0.09; 95% CI: 0.04, 0.14; P = 0.007), while in the eyes without congenital glaucoma the relationship was not statistically significant. In SHM in contrast to PHM, BM thickness and RPE cell density decrease in a parallel manner with longer axial length. The findings fit with the notion of BM being a primary driver in the process of axial elongation in PHM as compared to SHM.
引用
收藏
页数:7
相关论文
共 13 条
  • [1] Bruch' s membrane thickness in relationship to axial length
    Bai, Hai Xia
    Mao, Ying
    Shen, Ling
    Xu, Xiao Lin
    Gao, Fei
    Zhang, Zhi Bao
    Li, Bin
    Jonas, Jost B.
    [J]. PLOS ONE, 2017, 12 (08):
  • [2] Bruch's Membrane Thickness and Retinal Pigment Epithelium Cell Density in Experimental Axial Elongation
    Dong, Li
    Shi, Xu Han
    Kang, Yi Kun
    Wei, Wen Bin
    Wang, Ya Xing
    Xu, Xiao Lin
    Gao, Fei
    Jonas, Jost B.
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [3] Heine L., 1899, ARCH AUGENHEILKD, V38, P277
  • [4] BRUCH MEMBRANE AND THE MECHANISM OF MYOPIZATION A New Theory
    Jonas, Jost B.
    Ohno-Matsui, Kyoko
    Jiang, Wen Jun
    Panda-Jonas, Songhomitra
    [J]. RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (08): : 1428 - 1440
  • [5] Retinal pigment epithelium cell density in relationship to axial length in human eyes
    Jonas, Jost B.
    Ohno-Matsui, Kyoko
    Holbach, Leonard
    Panda-Jonas, Songhomitra
    [J]. ACTA OPHTHALMOLOGICA, 2017, 95 (01) : E22 - E28
  • [6] Retinal Thickness and Axial Length
    Jonas, Jost B.
    Xu, Liang
    Wei, Wen Bin
    Pan, Zhe
    Yang, Hua
    Holbach, Leonard
    Panda-Jonas, Songhomitra
    Wang, Ya Xing
    [J]. INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (04) : 1791 - 1797
  • [7] Histologic differences between primary high myopia and secondary high myopia due to congenital glaucoma
    Jonas, Jost B.
    Holbach, Leonard
    Panda-Jonas, Songhomitra
    [J]. ACTA OPHTHALMOLOGICA, 2016, 94 (02) : 147 - 153
  • [8] Bruch's membrane thickness in high myopia
    Jonas, Jost B.
    Holbach, Leonard
    Panda-Jonas, Songhomitra
    [J]. ACTA OPHTHALMOLOGICA, 2014, 92 (06) : E470 - E474
  • [9] Primary congenital glaucoma
    Ko, Fang
    Papadopoulos, Maria
    Khaw, Peng T.
    [J]. NEW TRENDS IN BASIC AND CLINICAL RESEARCH OF GLAUCOMA: A NEURODEGENERATIVE DISEASE OF THE VISUAL SYSTEM, PT B, 2015, 221 : 177 - 189
  • [10] A Pilot Study of Enhanced Depth Imaging Optical Coherence Tomography of the Choroid in Normal Eyes
    Margolis, Ron
    Spaide, Richard F.
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (05) : 811 - 815