Flow injection on-line solid phase extraction for ultra-trace lead determination with hydride generation electrothermal atomic absorption spectrometry

被引:6
作者
Sanchez Trujillo, Irene [1 ]
Alonso Castillo, Manuel L. [1 ]
Cano Pavon, Jose Manuel [1 ]
Vereda Alonso, Elisa I. [1 ]
Garcia de Torres, Amparo [1 ]
机构
[1] Univ Malaga, Fac Sci, Dept Analyt Chem, E-29071 Malaga, Spain
关键词
PRECONCENTRATION; SEPARATION; MODIFIER; PLATFORM; CADMIUM; SAMPLES;
D O I
10.1039/c3ay26471h
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The efficiencies of two types of chelating resins were evaluated and optimized for the extraction and determination of lead by flow injection graphite furnace and hydride generation atomic absorption spectrometry (FI-HG-ETAAS) in environmental water samples. The optimum analytical conditions were examined and the analytical features of each method were revealed and compared in terms of sensitivity, selectivity and accuracy. Lead determination by FI-HG-ETAAS using [1,5-bis(2-pyridyl)-3-sulphophenyl methylene] thiocarbonohydrazide immobilised on aminopropyl-controlled pore glass (PSTH-cpg, 55 nm) provides a detection limit of 3.0 ng l(-1) lead with a relative standard deviation (R. S. D.) of 2.5% at the 50 ng l(-1) level (n = 10) compared to silica gel funtionalized with methylthiosalicylate (TS-gel) which provides a detection limit of 82 ng l(-1). Under the optimal experimental conditions, with the use of PSTH-cpg and a tungsten-rhodium coated graphite furnace, an enhancement factor of 20 was obtained with a sample consumption of 6.4 ml, while an enhancement factor of 3.5 was obtained with the use of TS-gel. Both methods have been applied to the determination of low levels of lead in environmental water samples. The results obtained show good agreement with certified or expected values.
引用
收藏
页码:2551 / 2557
页数:7
相关论文
共 27 条
[1]   Determination of lead in dialysis concentrates using flow injection hydride generation atomic absorption spectrometry [J].
Berkkan, A ;
Ertas, N .
TALANTA, 2004, 64 (02) :423-427
[2]   Solid phase extraction of trace elements [J].
Camel, V .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2003, 58 (07) :1177-1233
[3]  
CASTILLO JR, 1985, MIKROCHIM ACTA, V1, P253
[4]   THE INFLUENCE OF CHELATING REAGENTS ON PLUMBANE GENERATION - DETERMINATION OF LEAD IN THE PRESENCE OF PAN-S [J].
CHEN, HW ;
TANG, FL ;
GU, C ;
BRINDLE, ID .
TALANTA, 1993, 40 (08) :1147-1155
[5]   Determination of trace lead by hydride generation-inductively coupled plasma-mass spectrometry [J].
Chen, SY ;
Zhang, ZF ;
Yu, HM ;
Liu, WQ ;
Sun, M .
ANALYTICA CHIMICA ACTA, 2002, 463 (02) :177-188
[6]   Determination of lead by flow injection hydride generation atomic absorption spectrometry with tetrahydroborate immobilized on an anion-exchange resin [J].
Chuachuad, W ;
Tyson, JF .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2005, 20 (04) :282-288
[7]   Mechanisms involved in chemical vapor generation by aqueous tetra hydroborate(III) derivatization - Role of hexacyanoferrate(III) in plumbane generation [J].
D'Ulivo, Alessandro ;
Onor, Massimo ;
Spiniello, Roberto ;
Pitzalis, Emanuela .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2008, 63 (08) :835-842
[8]  
Dedina J., 1995, HYDRIDE GENERATION A, V19, P288
[9]   Preconcentration and separation of nickel, copper and cobalt using solid phase extraction and their determination in some real samples [J].
Ghaedi, M. ;
Ahmadi, F. ;
Soylak, M. .
JOURNAL OF HAZARDOUS MATERIALS, 2007, 147 (1-2) :226-231
[10]  
Gouply J., 1991, PLANS EXPERIENCES SU, P253