An energy-saving oriented air balancing strategy for multi-zone demand-controlled ventilation system

被引:29
作者
Jing, Gang [1 ]
Cai, Wenjian [2 ]
Zhang, Xin [2 ]
Cui, Can [2 ]
Yin, Xiaohong [3 ]
Xian, Huacai [1 ]
机构
[1] Shandong Jiaotong Univ, Sch Transportat & Logist Engn, Jinan 250023, Shandong, Peoples R China
[2] Nanyang Technol Univ, Sch Elect & Elect Engn, Nanyang Ave, Singapore 639798, Singapore
[3] Qingdao Univ Sci & Technol, Sch Automat & Elect Engn, Qingdao 266042, Shandong, Peoples R China
基金
新加坡国家研究基金会;
关键词
Ventilation; Air balancing; Energy saving; Model based; Demand-controlled ventilation; Experimental assessment; MODEL; CONSUMPTION; PREDICTION; RETROFIT; MACHINE; SCHOOLS;
D O I
10.1016/j.energy.2019.02.044
中图分类号
O414.1 [热力学];
学科分类号
摘要
For addressing the energy waste resulted by over-ventilation or under-ventilation in conventional demand-controlled ventilation system, an air balancing strategy is proposed to solve the over-ventilation and under-ventilation problems of the multi-zone demand-controlled ventilation system. In this study, an energy-saving oriented mathematical model is constructed to simulate the non-linear behavior of the multi-zone ventilation system and Bayesian linear regression supervised machine learning algorithm is used to estimate the unknown parameters of the constructed model. On the basis of the developed model, the damper control method is established to determine the position of the damper according to the desired airflow rate to ensure the system well-balanced. Therefore, with the constructed system model and the damper control method, the system can be well-balanced to overcome the disadvantages of over-ventilation and under-ventilation, and consumes less energy compared to the system that are not balanced. The performance of the proposed air balancing strategy for demand-controlled ventilation system is practically tested in an experimental rig with five terminals and validated by comparing to the demand-controlled ventilation strategy without air balancing. The experimental results demonstrate that the proposed strategy achieved the desired airflow rate within 4.6% maximum absolute percentage error, and also achieved a maximum value 143% for fan power reduction compared to conventional the strategy without air balancing. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1053 / 1065
页数:13
相关论文
共 39 条
[1]   Review of modeling methods for HVAC systems [J].
Afram, Abdul ;
Janabi-Sharifi, Farrokh .
APPLIED THERMAL ENGINEERING, 2014, 67 (1-2) :507-519
[2]  
ASHRAE, 2008, ASHR DUCT FITT DAT V
[3]   Using regression analysis to predict the future energy consumption of a supermarket in the UK [J].
Braun, M. R. ;
Altan, H. ;
Beck, S. B. M. .
APPLIED ENERGY, 2014, 130 :305-313
[4]   EU energy and climate change strategy [J].
Carvalho, Maria da Graca .
ENERGY, 2012, 40 (01) :19-22
[5]   An innovative approach for demand side management - optimal chiller loading by simulated annealing [J].
Chang, Yung-Chung .
ENERGY, 2006, 31 (12) :1883-1896
[6]   Optimal chilled water temperature calculation of multiple chiller systems using Hopfield neural network for saving energy [J].
Chang, Yung-Chung ;
Chen, Wu-Hsing .
ENERGY, 2009, 34 (04) :448-456
[7]   Model-based method for testing, adjusting and balancing of HVAC duct system [J].
Chen, Haoran ;
Cai, Wenjian ;
Chen, Can .
ENERGY AND BUILDINGS, 2016, 126 :498-507
[8]   Achieving better energy-efficient air conditioning - A review of technologies and strategies [J].
Chua, K. J. ;
Chou, S. K. ;
Yang, W. M. ;
Yan, J. .
APPLIED ENERGY, 2013, 104 :87-104
[9]   A novel online air balancing method for the ventilation duct system via distributed cooperative control [J].
Cui, Can ;
Zhang, Xin ;
Cai, Wenjian ;
Jing, Gang .
BUILDING AND ENVIRONMENT, 2018, 146 :177-189
[10]   Airflow measurements using averaging Pitot tube under restricted conditions [J].
Cui, Can ;
Cai, Wenjian ;
Chen, Haoran .
BUILDING AND ENVIRONMENT, 2018, 139 :17-26