Tracer-kinetic modeling of dynamic contrast-enhanced MRI and CT: a primer

被引:92
作者
Ingrisch, Michael [1 ]
Sourbron, Steven [2 ]
机构
[1] Ludwig Maximilians Univ Hosp Munich, Inst Clin Radiol, D-81377 Munich, Germany
[2] Univ Leeds, Div Med Phys, Leeds LS2 9JT, W Yorkshire, England
关键词
DCE-MRI; DCE-CT; Tracer-kinetic modeling; Tissue perfusion; ARTERIAL INPUT FUNCTION; POSITRON-EMISSION-TOMOGRAPHY; MAGNETIC-RESONANCE PERFUSION; AKAIKE INFORMATION CRITERION; BRAIN-BARRIER PERMEABILITY; GLOMERULAR-FILTRATION-RATE; CEREBRAL BLOOD-VOLUME; IN-VIVO ASSESSMENT; MYOCARDIAL-PERFUSION; COMPUTED-TOMOGRAPHY;
D O I
10.1007/s10928-013-9315-3
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Dynamic contrast-enhanced computed tomography (DCE-CT) and magnetic resonance imaging (DCE-MRI) are functional imaging techniques. They aim to characterise the microcirculation by applying the principles of tracer-kinetic analysis to concentration-time curves measured in individual image pixels. In this paper, we review the basic principles of DCE-MRI and DCE-CT, with a specific emphasis on the use of tracer-kinetic modeling. The aim is to provide an introduction to the field for a broader audience of pharmacokinetic modelers. In a first part, we first review the key aspects of data acquisition in DCE-CT and DCE-MRI, including a review of basic measurement strategies, a discussion on the relation between signal and concentration, and the problem of measuring reference data in arterial blood. In a second part, we define the four main parameters that can be measured with these techniques and review the most common tracer-kinetic models that are used in this field. We first discuss the models for the capillary bed and then define the most general four-parameter models used today: the two-compartment exchange model, the tissue-homogeneity model, the "adiabatic approximation to the tissue-homogeneity model" and the distributed-parameter model. In simpler tissue types or when the data quality is inadequate to resolve all the features of the more complex models, it is often necessary to resort to simpler models, which are special cases of the general models and hence have less parameters. We discuss the most common of these special cases, i.e. the uptake models, the extended Tofts model, and the one-compartment model. Models for two specific tissue types, liver and kidney, are discussed separately. We conclude with a review of practical aspects of DCE-CT and DCE-MRI data analysis, including the problem of identifying a suitable model for any given data set, and a brief discussion of the application of tracer-kinetic modeling in the context of drug development. Here, an important application of DCE techniques is the derivation of quantitative imaging biomarkers for the assessment of effects of targeted therapeutics on tumors.
引用
收藏
页码:281 / 300
页数:20
相关论文
共 134 条
  • [1] The use of the Levenberg-Marquardt curve-fitting algorithm in pharmacokinetic modelling of DCE-MRI data
    Ahearn, TS
    Staff, RT
    Redpath, TW
    Semple, SIK
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (09) : N85 - N92
  • [2] Imaging of Stroke: Part 1, Perfusion CT-Overview of Imaging Technique, Interpretation Pearls, and Common Pitfalls
    Allmendinger, Andrew Mark
    Tang, Elizabeth R.
    Lui, Yvonne W.
    Spektor, Vadim
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (01) : 52 - 62
  • [3] Glomerular filtration rate: Assessment with dynamic contrast-enhanced MRI and a cortical-compartment model in the rabbit kidney
    Annet, L
    Hermoye, L
    Peeters, F
    Jamar, F
    Dehoux, JP
    Van Beers, BE
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (05) : 843 - 849
  • [4] [Anonymous], 2002, Model selection and multimodel inference: a practical informationtheoretic approach
  • [5] Tracer Kinetic Analysis of Dynamic Contrast-Enhanced MRI and CT Bladder Cancer Data: A Preliminary Comparison to Assess the Magnitude of Water Exchange Effects
    Bains, Lauren J.
    McGrath, Deirdre M.
    Naish, Josephine H.
    Cheung, Susan
    Watson, Yvonne
    Taylor, M. Ben
    Logue, John P.
    Parker, Geoffrey J. M.
    Waterton, John C.
    Buckley, David L.
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (02) : 595 - 603
  • [6] Detection of Hemodynamically Significant Coronary Artery Stenosis: Incremental Diagnostic Value of Dynamic CT-based Myocardial Perfusion Imaging
    Bamberg, Fabian
    Becker, Alexander
    Schwarz, Florian
    Marcus, Roy P.
    Greif, Martin
    von Ziegler, Franz
    Blankstein, Ron
    Hoffmann, Udo
    Sommer, Wieland H.
    Hoffmann, Verena S.
    Johnson, Thorsten R. C.
    Becker, Hans-Christoph R.
    Wintersperger, Bernd J.
    Reiser, Maximilian F.
    Nikolaou, Konstantin
    [J]. RADIOLOGY, 2011, 260 (03) : 689 - 698
  • [7] Quantitative assessment of rat kidney function by measuring the clearance of the contrast agent Gd(DOTA) using dynamic MRI
    Baumann, D
    Rudin, M
    [J]. MAGNETIC RESONANCE IMAGING, 2000, 18 (05) : 587 - 595
  • [8] MR first pass perfusion of benign and malignant cardiac tumours-significant differences and diagnostic accuracy
    Bauner, K. U.
    Sourbron, S.
    Picciolo, M.
    Schmitz, C.
    Theisen, D.
    Sandner, T. A.
    Reiser, M. F.
    Huber, A. M.
    [J]. EUROPEAN RADIOLOGY, 2012, 22 (01) : 73 - 82
  • [9] CT perfusion for the monitoring of neoadjuvant chemotherapy and radiation therapy in rectal carcinoma: Initial experience
    Bellomi, Massimo
    Petralia, Giuseppe
    Sonzogni, Angelica
    Zampino, Maria Giulia
    Rocca, Andrea
    [J]. RADIOLOGY, 2007, 244 (02) : 486 - 493
  • [10] Gadolinium-enhanced echo-planar T2-weighted MRI of tumors in the extracranial head and neck: Feasibility study and preliminary results using a distributed-parameter tracer kinetic analysis
    Bisdas, Sotirios
    Baghi, Mehran
    Wagenblast, Jens
    Vogl, Thomas J.
    Thng, Choon Hua
    Koh, Tong San
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (05) : 963 - 969