Design and Testing of a Percutaneously Implantable Fetal Pacemaker

被引:17
作者
Loeb, Gerald E. [1 ]
Zhou, Li [1 ]
Zheng, Kaihui [1 ]
Nicholson, Adriana [1 ]
Peck, Raymond A. [1 ]
Krishnan, Anjana [1 ]
Silka, Michael [2 ]
Pruetz, Jay [2 ]
Chmait, Ramen [3 ]
Bar-Cohen, Yaniv [2 ]
机构
[1] Univ So Calif, Dept Biomed Engn, Viterbi Sch Engn, Med Device Dev Facil, Los Angeles, CA 90089 USA
[2] Childrens Hosp Los Angeles, Keck Sch Med, Dept Pediat, Div Cardiol, Los Angeles, CA 90027 USA
[3] Univ So Calif, Keck Sch Med, Dept Obstet & Gynecol, Div Maternal Fetal Med, Los Angeles, CA 90027 USA
关键词
Cardiac pacemaker; Fetus; Congenital heart block; Complete heart block; Hydrops fetalis; COMPLETE HEART-BLOCK; INTRAVENOUS IMMUNOGLOBULIN; ATRIOVENTRICULAR-BLOCK; MULTICENTER; INJECTION; FETUSES;
D O I
10.1007/s10439-012-0631-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We are developing a cardiac pacemaker with a small, cylindrical shape that permits percutaneous implantation into a fetus to treat complete heart block and consequent hydrops fetalis, which can otherwise be fatal. The device uses off-the-shelf components including a rechargeable lithium cell and a highly efficient relaxation oscillator encapsulated in epoxy and glass. A corkscrew electrode made from activated iridium can be screwed into the myocardium, followed by release of the pacemaker and a short, flexible lead entirely within the chest of the fetus to avoid dislodgement from fetal movement. Acute tests in adult rabbits demonstrated the range of electrical parameters required for successful pacing and the feasibility of successfully implanting the device percutaneously under ultrasonic imaging guidance. The lithium cell can be recharged inductively as needed, as indicated by a small decline in the pulsing rate.
引用
收藏
页码:17 / 27
页数:11
相关论文
共 50 条
  • [21] Permanent Pacemaker and Implantable Cardioverter Defibrillator Infections: Seven Years of Diagnostic and Therapeutic Experience of a Single Center
    Cengiz, Mustafa
    Okutucu, Sercan
    Ascioglu, Sibel
    Sahin, Abdurrahman
    Aksoy, Hakan
    Deveci, Onur Sinan
    Kaya, Ergun Baris
    Aytemir, Kudret
    Kabakci, Giray
    Tokgozoglu, Late
    Ozkutlu, Hilmi
    Oto, Ali
    CLINICAL CARDIOLOGY, 2010, 33 (07) : 406 - 411
  • [22] Interference of cardiac pacemaker and implantable cardioverter-defibrillator activity during electronic dental device use
    Roedig, Jason J.
    Shah, Jignesh
    Elayi, Claude Samy
    Miller, Craig S.
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2010, 141 (05) : 521 - 526
  • [23] Magnetic resonance imaging safety in pacemaker and implantable cardioverter defibrillator patients: how far have we come?
    Nordbeck, Peter
    Ertl, Georg
    Ritter, Oliver
    EUROPEAN HEART JOURNAL, 2015, 36 (24) : 1505 - U81
  • [24] A Band Pass Filter to Near Infrared Charging for Implantable Cardiac Pacemaker and ECG Micro-Stimulator Application
    Lai, Wen Cheng
    2015 IEEE MTT-S INTERNATIONAL MICROWAVE WORKSHOP SERIES ON RF AND WIRELESS TECHNOLOGIES FOR BIOMEDICAL AND HEALTHCARE APPLICATIONS (IMWS-BIO), 2015, : 51 - 52
  • [25] Evaluation of Safety and Efficacy of Qinming8631 DR Implantable Cardiac Pacemaker in Chinese Patients: A Prospective, Multicenter, Randomized Controlled Trial of the First Domestically Developed Pacemaker of China
    Xiang, Mei-Xiang
    Wang, Dong-Qi
    Xu, Jing
    Zhang, Zheng
    Hu, Jian-Xin
    Wang, Dong-Mei
    Gu, Xiang
    Liu, He-Ping
    Guo, Tao
    Yang, Xiang-Jun
    Ling, Feng
    Lin, Jia-Feng
    Cai, Shang-Lang
    Zhu, Guo-Bin
    Wang, Jian-An
    CHINESE MEDICAL JOURNAL, 2016, 129 (22) : 2659 - +
  • [26] Evaluation of Safety and Efficacy of Qinming8631 DR Implantable Cardiac Pacemaker in Chinese Patients: A Prospective, Multicenter, Randomized Controlled Trial of the First Domestically Developed Pacemaker of China
    Xiang MeiXiang
    Wang DongQi
    Xu Jing
    Zhang Zheng
    Hu JianXin
    Wang DongMei
    Gu Xiang
    Liu HePing
    Guo Tao
    Yang XiangJun
    Ling Feng
    Lin JiaFeng
    Cai ShangLang
    Zhu GuoBin
    Wang JianAn
    Department of Cardiology Cardiovascular Key Laboratory of Zhejiang Province The Second Affiliated Hospital of Zhejiang University School of Medicine Hangzhou Zhejiang China
    Department of Cardiology The First Affiliated Hospital of Xian Jiaotong University Xian Shaanxi China
    Department of Cardiology Tianjin Chest Hospital Tianjin China
    Department of Cardiology The First Hospital of Lanzhou University Lanzhou Gansu China
    Department of Cardiology The Second Affiliated Hospital of Nanchang University Nanchang Jiangxi China
    Department of Cardiology Bethune International Peace Hospital of the Chinese PLA Shijiazhuang Hebei China
    Department of Cardiology Northern Jiangsu Peoples Hospital Yangzhou Jiangsu China
    Department of Cardiology Jilin Province Peoples Hospital Changchun Jilin China
    Department of Cardiology The First Affiliated Hospital of Kunming Medical University Kunming Yunnan China
    Department of Cardiology The First Affiliated Hospital of Suzhou University Suzhou Jiangsu China
    Department of Cardiology The First Peoples Hospital of Hangzhou Hangzhou Zhejiang China
    Department of Cardiology The Second Affiliated Hospital of Wenzhou Medical University Wenzhou Zhejiang China
    Department of Cardiology The Affiliated Hospital of Qingdao University Medical College Qingdao Shandong China
    Department of Cardiology The Second Hospital of Shanxi Medical University Taiyuan Shanxi China
    中华医学杂志英文版, 2016, 129 (22) : 2659 - 2665
  • [27] Design of PIλDδ-Heart Rate Controllers for Cardiac Pacemaker
    Momani, Shaker
    Batiha, Iqbal M.
    El-Khazali, Reyad
    2019 IEEE 19TH INTERNATIONAL SYMPOSIUM ON SIGNAL PROCESSING AND INFORMATION TECHNOLOGY (ISSPIT 2019), 2019,
  • [28] Fetal fibronectin testing for reducing the risk of preterm birth
    Berghella, Vincenzo
    Saccone, Gabriele
    COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2019, (07):
  • [29] Multilayer Phantom for Electical Impedance Testing of a Fetal Heartbeat
    Rezhdo, A.
    Agrawal, S.
    Wu, X.
    2014 40TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE (NEBEC), 2014,
  • [30] Factors that increase reactivity during fetal nonstress testing
    Esin, Sertac