Short-term outcome of routine use of EndoFLIP during hiatal hernia repair

被引:16
作者
Nwokedi, Ugoeze [1 ,2 ]
Duc T Nguyen [3 ]
Meisenbach, Leonora M. [1 ,2 ]
Chihara, Ray [1 ,2 ]
Chan, Edward Y. [1 ,2 ]
Graviss, Edward A. [3 ,4 ]
Kim, Min P. [1 ,2 ]
机构
[1] Houston Methodist Hosp, Dept Surg, Div Thorac Surg, 6550 Fannin St,Suite 1661, Houston, TX 77030 USA
[2] Houston Methodist Hosp, Weill Cornell Med Coll, Dept Surg & Cardiothorac Surg, Houston, TX 77030 USA
[3] Houston Methodist Res Inst, Dept Pathol & Genom Med, Houston, TX USA
[4] Houston Methodist Hosp, Dept Surg, Houston, TX 77030 USA
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2021年 / 35卷 / 07期
关键词
EndoFLIP; Endoluminal functional lumen imaging probe; Hiatal hernia repair; Magnetic sphincter augmentation; Distensibility index; Dysphagia; GERD-HRQL; ESOPHAGOGASTRIC JUNCTION DISTENSIBILITY; LUMEN IMAGING PROBE;
D O I
10.1007/s00464-020-07788-x
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background Endoluminal functional lumen imaging probe (EndoFLIP) technology is a tool that can be used to provide intraoperative objective real-time feedback during hiatal hernia repair. We wanted to determine the implication of initial distensibility index (DI) after mobilization of hiatus and final DI after creation of barrier in short-term clinical outcomes. Methods We performed a retrospective analysis of prospectively collected data on the intraoperative use of EndoFLIP during hiatal hernia repair at a single institution from 2017 to 2019. We analyzed the initial DI and final DI with the short-term clinical outcomes. Results There were 163 patients who had Nissen (n = 16), Toupet (n = 79) or magnetic sphincter augmentation (n = 68) with (n = 158) or without (n = 5) hiatal hernia repair with median initial DI was 3.2 mm(2)/mmHg. We used 3 mm(2)/mmHg as the cutoff for low (n = 84) vs. high (n = 79) initial DI group. There was no difference in DeMeester score (p = 0.76), the peristalsis on manometry (p = 0.13), type of hiatal hernia (p = 0.98), and GERD-HRQL score prior to surgery (p = 0.73) between the groups. There was significantly higher final DI in the high initial DI group compared to low initial DI group; however, there was no significant difference in the GERD-HRQL score at 1-3 months (p = 0.28). All of the patients had a final DI > 0.5 mm(2)/mmHg at the end of the case with median final DI of 1.6 mm(2/)mmHg. None of these patients required steroids (0%) and only one patient (0.6%) required EGD and dilatation as well as re-operation for dysphagia within 3 months. Conclusions The initial DI was associated with final DI, but it did not correlate with improvement in short-term GERD-HRQL score. Final DI maintained above the cutoff value led to most of the patients not to require intervention for dysphagia. Use of the EndoFLIP can provide objective data during the operation and prevent severe dysphagia after repair.
引用
收藏
页码:3840 / 3849
页数:10
相关论文
共 17 条
[11]   Esophagogastric junction distensibility in hiatus hernia [J].
Lottrup, C. ;
McMahon, B. P. ;
Ejstrud, P. ;
Ostapiuk, M. A. ;
Funch-Jensen, P. ;
Drewes, A. M. .
DISEASES OF THE ESOPHAGUS, 2016, 29 (05) :463-471
[12]   Adult esophagogastric junction distensibility during general anesthesia assessed with an endoscopic functional luminal imaging probe (EndoFLIP®) [J].
Nathanson, Leslie K. ;
Brunott, Nathan ;
Cavallucci, David .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2012, 26 (04) :1051-1055
[13]   Improving functional esophageal surgery with a "smart" bougie: endoflip [J].
Perretta, Silvana ;
Dallemagne, Bernard ;
McMahon, Barry ;
D'Agostino, Jacopo ;
Marescaux, Jacques .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2011, 25 (09) :3109-3109
[14]   Hiatal hernia recurrence following magnetic sphincter augmentation and posterior cruroplasty: intermediate-term outcomes [J].
Rona, Kais A. ;
Tatum, James M. ;
Zehetner, Joerg ;
Schwameis, Katrin ;
Chow, Carol ;
Samakar, Kamran ;
Dobrowolsky, Adrian ;
Houghton, Caitlin C. ;
Bildzukewicz, Nikolai ;
Lipham, John C. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2018, 32 (07) :3374-3379
[15]   Using impedance planimetry (EndoFLIP™) in the operating room to assess gastroesophageal junction distensibility and predict patient outcomes following fundoplication [J].
Su, Bailey ;
Novak, Stephanie ;
Callahan, Zachary M. ;
Kuchta, Kristine ;
Carbray, JoAnn ;
Ujiki, Michael B. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2020, 34 (04) :1761-1768
[16]   Measurement of esophago-gastric junction cross-sectional area and distensibility by an endolumenal functional lumen imaging probe for the diagnosis of gastroesophageal reflux disease [J].
Tucker, E. ;
Sweis, R. ;
Anggiansah, A. ;
Wong, T. ;
Telakis, E. ;
Knowles, K. ;
Wright, J. ;
Fox, M. .
NEUROGASTROENTEROLOGY AND MOTILITY, 2013, 25 (11) :904-910
[17]   Is that 'floppy' fundoplication tight enough? [J].
Turner, Brexton ;
Helm, Melissa ;
Hetzel, Emily ;
Gould, Jon C. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2020, 34 (04) :1823-1828