Combined drug screening and confirmation by liquid chromatography time-of-flight mass spectrometry with reverse database search

被引:33
作者
de Castro, Ana [2 ,3 ]
Gergov, Merja [1 ]
Ostman, Pekka [1 ]
Ojanpera, Ilkka [1 ]
Pelander, Anna [1 ]
机构
[1] Univ Helsinki, Hjelt Inst, Dept Forens Med, Helsinki 00014, Finland
[2] Cienytech, Res Dept, Santiago De Compostela 15705, Spain
[3] Fac Med, Inst Forens Sci, Santiago De Compostela 15782, Spain
关键词
LC-TOFMS; Drug screening; Confirmation; Identification; PESTICIDE-RESIDUES; RESOLVING POWER; PRODUCT IONS; FULL-SCAN; IDENTIFICATION; FOOD; URINE;
D O I
10.1007/s00216-012-5889-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method based on in-source collision-induced dissociation (ISCID) liquid chromatography time-of-flight mass spectrometry (LC-TOFMS) and reverse target database search was developed and evaluated for drug screening and confirmation in analytical toxicology context. An established LC-TOFMS screening method, in which identification relies solely on protonated molecule accurate mass measurement, isotopic pattern fit, and retention time (RT), was completed to include 1-3 qualifier ions for each analyte in the database. The qualifier ions for 431 compounds were selected from the experimental ISCID spectra, and their molecular formulae were assigned by applying SmartFormula3D and MSFragmenter software. Three qualifier ions were assigned for 64.5%, two or three for 81.4%, one for 14.8%, and none for 3.7% of the compounds studied. Comparison between ISCID LC-TOFMS and LC-TOFMS with 25 authentic autopsy urine samples showed an improved confidence level with the ISCID method, as isomeric interferences were excluded in most cases. However, some false negative (FN) results were obtained at low concentration levels close to the reporting criteria. The cut-off concentration of the ISCID method was 10-100 ng/mL with 80% of the 49 representative compounds tested, and the level was approximately two times higher than that obtained by LC ion trap MS. The presented method enables simultaneous screening and confirmation whenever at least one qualifier ion is available, as applying an accurate mass precursor ion and one product ion surpasses the standard of four identification points that is required by the current EU protocol.
引用
收藏
页码:1265 / 1278
页数:14
相关论文
共 34 条
[1]   Development and practical application of a library of CID accurate mass spectra of more than 2,500 toxic compounds for systematic toxicological analysis by LC-QTOF-MS with data-dependent acquisition [J].
Broecker, Sebastian ;
Herre, Sieglinde ;
Wuest, Bernhard ;
Zweigenbaum, Jerry ;
Pragst, Fritz .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (01) :101-117
[2]  
Decaestecker TN, 2000, RAPID COMMUN MASS SP, V14, P1787, DOI 10.1002/1097-0231(20001015)14:19<1787::AID-RCM94>3.0.CO
[3]  
2-S
[4]   ESI-MS/MS library of 1,253 compounds for application in forensic and clinical toxicology [J].
Dresen, Sebastian ;
Gergov, Merja ;
Politi, Lucia ;
Halter, Claudia ;
Weinmann, Wolfgang .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2009, 395 (08) :2521-2526
[5]  
Eckers C, 1997, RAPID COMMUN MASS SP, V11, P1916, DOI 10.1002/(SICI)1097-0231(199711)11:17<1916::AID-RCM96>3.0.CO
[6]  
2-8
[7]  
Ferrer I., 2009, Liquid chromatography time-of-flight mass spectrometry
[8]   Multi-residue method for the analysis of 101 pesticides and their degradates in food and water samples by liquid chromatography/time-of-flight mass spectrometry [J].
Ferrer, Imma ;
Thurman, E. Michael .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1175 (01) :24-37
[9]   Determination of Pesticide Residues in Fruit-Based Soft Drinks [J].
Garcia-Reyes, Juan F. ;
Gilbert-Lopez, Bienvenida ;
Molina-Diaz, Antonio ;
Fernandez-Alba, Amadeo R. .
ANALYTICAL CHEMISTRY, 2008, 80 (23) :8966-8974
[10]   Toxicological screening of urine for drugs by liquid chromatography/time-of-flight mass spectrometry with automated target library search based on elemental formulas [J].
Gergov, M ;
Boucher, B ;
Ojanperä, I ;
Vuori, E .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (08) :521-526