Assessment of Virtual-Voltage-Based Model Predictive Controllers in Six-Phase Drives Under Open-Phase Faults

被引:63
作者
Gonzalez-Prieto, Ignacio [1 ]
Duran, Mario J. [1 ]
Bermudez, Mario [2 ]
Barrero, Federico [3 ]
Martin, Cristina [3 ]
机构
[1] Univ Malaga, Dept Elect Engn, Malaga 29016, Spain
[2] Univ Huelva, Dept Elect Engn, Huelva 21007, Spain
[3] Univ Seville, Dept Elect Engn, Seville 41004, Spain
关键词
Fault tolerance; Fault tolerant systems; Switches; Predictive models; Predictive control; Stators; Voltage control; Model predictive control (MPC); postfault operation; six-phase induction machines (IMs); virtual-voltage vectors (VVs); 5-PHASE INDUCTION-MOTOR; DUAL 3-PHASE MACHINES; DIRECT TORQUE CONTROL; PARAMETER-IDENTIFICATION; OPERATION;
D O I
10.1109/JESTPE.2019.2915666
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The inherent fault-tolerant capability of multiphase machines is highly appreciated, but it requires fault detection and localization together with a reconfiguration of the control scheme. When the multiphase machine is regulated using finite-control set model predictive control (MPC) strategies, the reconfiguration involves the use of different transformation matrices, cost functions, and current references for each of the multiple open-phase fault (OPF) scenarios. Aiming to simplify this procedure and add further robustness, this paper explores the possibility to achieve a natural fault-tolerant capability by maintaining the prefault control strategy after the fault occurrence. For this purpose, this paper first analyzes the two main reasons why MPC-regulated multiphase drives misbehave in the event of an OPF: the voltage vector shifting and the search for incompatible goals. In the next step, a version of the MPC that includes virtual-voltage vectors (VVs) is tested for the first time in postfault situation and it is compared to conventional MPC technique. Extensive experimental results reveal that, while MPC misbehaves in the event of an OPF, the VV-MPC provides a satisfactory ripple-free postfault performance. This finding has two significant implications for industrial applications: the postfault operation is highly simplified and, at the same time, the fault-tolerant multiphase drive becomes immune to fault detection errors and delays.
引用
收藏
页码:2634 / 2644
页数:11
相关论文
共 35 条
  • [1] [Anonymous], 2016, GAMESA 5 0 MW GAMESA
  • [2] Comparison of Postfault Strategies for Current Reference Generation for Dual Three-Phase Machines in Terms of Converter Losses
    Baneira, Fernando
    Doval-Gandoy, Jesus
    Yepes, Alejandro G.
    Lopez, Oscar
    Perez-Estevez, D.
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (11) : 8243 - 8246
  • [3] Control Strategy for Multiphase Drives With Minimum Losses in the Full Torque Operation Range Under Single Open-Phase Fault
    Baneira, Fernando
    Doval-Gandoy, Jesus
    Yepes, Alejandro G.
    Lopez, Oscar
    Perez-Estevez, Diego
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2017, 32 (08) : 6275 - 6285
  • [4] An Experimental Assessment of Open-Phase Fault-Tolerant Virtual-Vector-Based Direct Torque Control in Five-Phase Induction Motor Drives
    Bermudez, Mario
    Gonzalez-Prieto, Ignacio
    Barrero, Federico
    Guzman, Hugo
    Kestelyn, Xavier
    Duran, Mario J.
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (03) : 2774 - 2784
  • [5] Open-Phase Fault-Tolerant Direct Torque Control Technique for Five-Phase Induction Motor Drives
    Bermudez, Mario
    Gonzalez-Prieto, Ignacio
    Barrero, Federico
    Guzman, Hugo
    Duran, Mario J.
    Kestelyn, Xavier
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2017, 64 (02) : 902 - 911
  • [6] Postfault Operation of an Asymmetrical Six-Phase Induction Machine With Single and Two Isolated Neutral Points
    Che, Hang Seng
    Duran, Mario J.
    Levi, Emil
    Jones, Martin
    Hew, Wooi-Ping
    Abd Rahim, Nasrudin
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2014, 29 (10) : 5406 - 5416
  • [7] Operation of a Six-Phase Induction Machine Using Series-Connected Machine-Side Converters
    Che, Hang Seng
    Levi, Emil
    Jones, Martin
    Duran, Mario J.
    Hew, Wooi-Ping
    Abd Rahim, Nasrudin
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (01) : 164 - 176
  • [8] Duran M. J., 2017, WILEY ENCY ELECT ELE, P1
  • [9] A New Algorithm for Real-Time Multiple Open-Circuit Fault Diagnosis in Voltage-Fed PWM Motor Drives by the Reference Current Errors
    Estima, Jorge O.
    Marques Cardoso, Antonio J.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (08) : 3496 - 3505
  • [10] Open-Circuit Fault Diagnosis in PMSG Drives for Wind Turbine Applications
    Freire, Nuno M. A.
    Estima, Jorge O.
    Marques Cardoso, Antonio J.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (09) : 3957 - 3967