Analysis of smear in high-resolution remote sensing satellites

被引:1
|
作者
Wahballah, Walid A. [1 ]
Bazan, Taher M. [1 ]
El-Tohamy, Fawzy [1 ]
Fathy, Mahmoud [2 ]
机构
[1] Egyptian Armed Forces, Cairo, Egypt
[2] Benha Univ, Cairo, Egypt
来源
SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES XX | 2016年 / 10000卷
关键词
Remote sensing satellite; Image motion; Clocking; TDI-CCD; Smear; MTF;
D O I
10.1117/12.2241634
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
High-resolution remote sensing satellites (HRRSS) that use time delay and integration (TDI) CCDs have the potential to introduce large amounts of image smear. Clocking and velocity mismatch smear are two of the key factors in inducing image smear. Clocking smear is caused by the discrete manner in which the charge is clocked in the TDI-CCDs. The relative motion between the HRRSS and the observed object obliges that the image motion velocity must be strictly synchronized with the velocity of the charge packet transfer (line rate) throughout the integration time. During imaging an object off-nadir, the image motion velocity changes resulting in asynchronization between the image velocity and the CCD's line rate. A Model for estimating the image motion velocity in HRRSS is derived. The influence of this velocity mismatch combined with clocking smear on the modulation transfer function (MTF) is investigated by using Matlab simulation. The analysis is performed for cross-track and along-track imaging with different satellite attitude angles and TDI steps. The results reveal that the velocity mismatch ratio and the number of TDI steps have a serious impact on the smear MTF; a velocity mismatch ratio of 2% degrades the MTFsmear by 32% at Nyquist frequency when the TDI steps change from 32 to 96. In addition, the results show that to achieve the requirement of MTFsmear >= 0.95, for TDI steps of 16 and 64, the allowable roll angles are 13.7 degrees and 6.85 degrees and the permissible pitch angles are no more than 9.6 degrees and 4.8 degrees, respectively.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Performance of Ultra-High-Resolution Computed Tomography in Super High-Resolution Mode at the Routine Radiation Dose: Phantom Study
    Kitera, Nobuo
    Fujioka, Chikako
    Higaki, Toru
    Nishimaru, Eiji
    Yokomachi, Kazushi
    Kiguchi, Masao
    Awai, Kazuo
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2022, 46 (06) : 900 - 905
  • [32] Analysis of the factors which influence the image quality of the remote sensing camera
    Fan, Chao
    Liang, Y. T.
    Li, W.
    Wang, F.
    2008 PROCEEDINGS OF INFORMATION TECHNOLOGY AND ENVIRONMENTAL SYSTEM SCIENCES: ITESS 2008, VOL 1, 2008, : 917 - 921
  • [33] Integrated Analysis of FORMOSAT-5 Remote Sensing Instrument in Space
    Chen, Chia-Ray
    Chen, Ching-Wei
    Yang, Mei-Yi
    Ho, Cheng-En
    Hung, Heng-Chuan
    Chang, Shenq-Tsong
    Huang, Ting-Ming
    OPTICAL MODELING AND PERFORMANCE PREDICTIONS VI, 2013, 8840
  • [34] In-orbit lunar imaging and analysis for optical remote sensing satellite
    Lu, Chunling
    Bai, Zhaoguang
    Li, Yongchang
    SENSORS, SYSTEMS, AND NEXTGENERATION SATELLITES XXIII, 2019, 11151
  • [35] High resolution computed tomography findings in smear-negative pulmonary tuberculosis patients according to their culture status
    Caliskan, Tayfun
    Ozkisa, Tuncer
    Aribal, Serkan
    Kaya, Hatice
    Incedayi, Mehmet
    Ulcay, Asim
    Ciftci, Faruk
    JOURNAL OF THORACIC DISEASE, 2014, 6 (06) : 706 - 712
  • [36] Imaging noise analyzing and suppressing for Tianwen-1 high-resolution camera
    Zhou P.
    Wang X.
    Dong J.
    Hao X.
    Huang J.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2022, 30 (02): : 217 - 226
  • [37] Development of the High-Resolution Scintillator Type Imager Using Si GRID Structures
    Tabata, K.
    Ohtake, R.
    Nishizawa, J.
    Koike, A.
    Aoki, T.
    4TH INTERNATIONAL CONFERENCE ON NANOTECHNOLOGIES AND BIOMEDICAL ENGINEERING, ICNBME-2019, 2020, 77 : 731 - 734
  • [38] Design of auto-exposure imaging circuit under complex illuminance of Mars in Tianwen-1 high-resolution camera
    Huang J.
    Wang X.
    Sun Z.
    Zhou D.
    Zhou P.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2022, 30 (02): : 191 - 198
  • [39] Evaluation of scanners and CCD cameras for high-resolution TEM of protein crystals and single particles
    Hesse, J
    Hebert, H
    Koeck, PJB
    MICROSCOPY RESEARCH AND TECHNIQUE, 2000, 49 (03) : 292 - 300
  • [40] On-Orbit Measurement and Analysis of the Micro-vibration in a Remote-Sensing Satellite
    Yu D.
    Wang G.
    Zhao Y.
    Advances in Astronautics Science and Technology, 2018, 1 (2) : 191 - 195