Microbubble-enhanced functional changes in arteries induced by pulsed high-intensity focused ultrasound exposure

被引:3
作者
Yang, Feng-Yi [1 ]
Chen, Chien-Cheng [2 ]
Horng, Shih-Cheng [3 ]
Chiu, Wei-Hsiu [1 ]
Yeh, Chi-Fang [1 ]
机构
[1] Natl Yang Ming Univ, Sch Biomed Sci & Engn, Dept Biomed Imaging & Radiol Sci, Taipei 112, Taiwan
[2] Cheng Hsin Rehabil Med Ctr, Dept Phys Med & Rehabil, Taipei, Taiwan
[3] Chaoyang Univ Technol, Dept Comp Sci & Informat Engn, Taichung, Taichung County, Taiwan
关键词
Ultrasound contrast agent; Pulsed-HIFU; Blood flow velocity; Peak systolic velocity; BLOOD-BRAIN-BARRIER; MRI;
D O I
10.1016/j.medengphy.2011.07.021
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study is to investigate the dose-dependent effects of ultrasound contrast agent (UCA) on the changes of peak systolic velocity (PSV) and pulsatility index (PI) in the arteries of 24 male Sprague-Dawley rats. The rats were sonicated with 1.0-MHz pulsed high-intensity focused ultrasound (HIFU) at two acoustic powers,15 W and 30W, with UCA present at four concentrations (0,150,300, and 450 mu L/kg). Ultrasound imaging was used to localize and to monitor the pulsed-HIFU exposure. The mean PSV of blood flow, as measured by Doppler ultrasound imaging, increased immediately in the arteries where UCA has been administrated at all four doses after pulsed-HIFU at 15W. However, the normalized PSV change decreased with each injected dose of UCA at 30W. Furthermore, the normalized pulsatility index changes increased as the injected dose of UCA increased at two acoustic powers. No obvious changes were found in terms of histological structures and temperature rise at the vessel wall. Our results demonstrated that the response of the artery to pulsed-HIFU was dependent on UCA dose at the same acoustic power. The value of normalized PSV change was minimal and the normalized PI change reached a maximum when the UCA dose was at the highest dose of UCA (450 mu L/kg) with the two acoustic powers. (C) 2011 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:313 / 317
页数:5
相关论文
共 16 条
  • [11] MRI study of hepatic tumours following high intensity focused ultrasound surgery
    Rowland, IJ
    Rivens, I
    Chen, L
    Lebozer, CH
    Collins, DJ
    terHaar, GR
    Leach, MO
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1997, 70 : 144 - 153
  • [12] Therapeutic applications of lipid-coated microbubbles
    Unger, EC
    Porter, T
    Culp, W
    Labell, R
    Matsunaga, T
    Zutshi, R
    [J]. ADVANCED DRUG DELIVERY REVIEWS, 2004, 56 (09) : 1291 - 1314
  • [13] Real-time visualization of high-intensity focused ultrasound treatment using ultrasound imaging
    Vaezy, S
    Shi, XG
    Martin, RW
    Chi, E
    Nelson, PI
    Bailey, MR
    Crum, LA
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (01) : 33 - 42
  • [14] Quantitative evaluation of the use of microbubbles with transcranial focused ultrasound on blood-brain-barrier disruption
    Yang, Feng-Yi
    Fu, Wen-Mei
    Chen, Wen-Shiang
    Yeh, Wei-Lan
    Lin, Win-Li
    [J]. ULTRASONICS SONOCHEMISTRY, 2008, 15 (04) : 636 - 643
  • [15] Functional Changes in Arteries Induced by Pulsed High-Intensity Focused Ultrasound
    Yang, Feng-Yi
    Chiu, Wei-Hsiu
    Liu, Shing-Hwa
    Lin, Guan-Liang
    Ho, Feng-Ming
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (12) : 2643 - 2649
  • [16] Microbubble-enhanced hemorrhage control using high intensity focused ultrasound
    Zderic, Vesna
    Brayman, Andrew A.
    Sharar, Sam R.
    Crum, Lawrence A.
    Vaezy, Shahram
    [J]. ULTRASONICS, 2006, 45 (1-4) : 113 - 120