Low-load behaviour of the patellar tendon graft and its relevance to the biomechanics of the reconstructed knee

被引:34
作者
Chandrashekar, Naveen [3 ]
Hashemi, Javad [1 ,2 ]
Slauterbeck, James [4 ]
Beynnon, Bruce D. [4 ]
机构
[1] Texas Tech Univ, Hlth Sci Ctr, Dept Orthoped Surg, Lubbock, TX 79430 USA
[2] Texas Tech Univ, Dept Mech Engn, Lubbock, TX 79409 USA
[3] Univ Waterloo, Dept Mech & Mechatron Engn, Waterloo, ON N2L 3G1, Canada
[4] Univ Vermont, Dept Orthopaed Rehabil, Burlington, VT 05405 USA
关键词
patellar tendon; graft properties; toe-region; graft initial tension;
D O I
10.1016/j.clinbiomech.2008.03.070
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. Although the linear elastic (high-load) properties of patellar tendon graft used for anterior cruciate ligament (ACL) reconstruction are studied extensively, the low-load properties of the graft, associated with the toe region of its load-deformation curve, are largely neglected. The objectives of this study were to (i) determine the properties of the patellar tendon in the low-load region and compare to that of the intact ACL, (ii) assess the extent of variability in these properties and relate them to donor factors, and (iii) establish the theoretical importance of low-load properties to the function of the reconstructed knee. Methods. The patellar tendons of 20 unpaired fresh frozen human knees (10 males and 10 females) were harvested. The central portions were trimmed, measured, and tested in tension to failure. The stress-strain curves were fitted with a bi-linear model and the graft properties were measured. Findings. The low-load region modulus of elasticity, E-0, of the patellar tendon, ranged from 49 MPa to 276 MPa in males and 63 MPa to 279 MPa in females. The strain at which the graft transitions from its low-load region to its linear elastic region (epsilon(*) similar to 4.6%) is on average above the strain levels experienced by the ACL during daily activities (epsilon similar to 4%). Donor sex, height and body mass were found to significantly affect some of the mechanical properties of the low-load region. Interpretation. The results suggest that the low-load region properties of the patellar tendon, not the linear elastic properties, govern the biomechanics of the tibiofemoral joint during the early healing period. Also, a wide variability of graft properties in the low-load region exists partly due to certain donor factors. Clinicians should be aware of the low-load region behaviour of the graft and its influence on time = 0 behaviour of the reconstructed knee. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:918 / 925
页数:8
相关论文
共 31 条
  • [11] COMPARISON OF MATERIAL PROPERTIES IN FASCICLE-BONE UNITS FROM HUMAN PATELLAR TENDON AND KNEE LIGAMENTS
    BUTLER, DL
    KAY, MD
    STOUFFER, DC
    [J]. JOURNAL OF BIOMECHANICS, 1986, 19 (06) : 425 - 432
  • [12] Sex-based differences in the tensile properties of the human anterior cruciate ligament
    Chandrashekar, Naveen
    Mansouri, Hossein
    Slauterbeck, James
    Hashemi, Javad
    [J]. JOURNAL OF BIOMECHANICS, 2006, 39 (16) : 2943 - 2950
  • [13] THE STRENGTH OF THE CENTRAL 3RD PATELLAR TENDON GRAFT - A BIOMECHANICAL STUDY
    COOPER, DE
    DENG, XHH
    BURSTEIN, AL
    WARREN, RF
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1993, 21 (06) : 818 - 824
  • [14] Anisotropic and inhomogeneous tensile behavior of the human anulus fibrosus: Experimental measurement and material model predictions
    Elliott, DM
    Setton, LA
    [J]. JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (03): : 256 - 263
  • [15] Garth W P Jr, 1992, Orthop Rev, V21, P565
  • [16] The mechanical properties of the human patellar tendon are correlated to its mass density and are independent of sex
    Hashemi, J
    Chandrashekar, N
    Slauterbeck, J
    [J]. CLINICAL BIOMECHANICS, 2005, 20 (06) : 645 - 652
  • [17] THE EFFECTS OF TEST ENVIRONMENT AND CYCLIC STRETCHING ON THE FAILURE PROPERTIES OF HUMAN PATELLAR TENDONS
    HAUT, RC
    POWLISON, AC
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (04) : 532 - 540
  • [18] TENSILE AND VISCOELASTIC PROPERTIES OF HUMAN PATELLAR TENDON
    JOHNSON, GA
    TRAMAGLINI, DM
    LEVINE, RE
    OHNO, K
    CHOI, NY
    WOO, SLY
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1994, 12 (06) : 796 - 803
  • [19] The effect of nonphysiologically high initial tension on the mechanical properties of in situ frozen anterior cruciate ligament in a canine model
    Katsuragi, R
    Yasuda, K
    Tsujino, J
    Keira, M
    Kaneda, K
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2000, 28 (01) : 47 - 56
  • [20] The biological and biomechanical effect of different graft tensioning in anterior cruciate ligament reconstruction: an experimental study
    Labs, K
    Perka, C
    Schneider, F
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2002, 122 (04) : 193 - 199