Low-load behaviour of the patellar tendon graft and its relevance to the biomechanics of the reconstructed knee

被引:34
作者
Chandrashekar, Naveen [3 ]
Hashemi, Javad [1 ,2 ]
Slauterbeck, James [4 ]
Beynnon, Bruce D. [4 ]
机构
[1] Texas Tech Univ, Hlth Sci Ctr, Dept Orthoped Surg, Lubbock, TX 79430 USA
[2] Texas Tech Univ, Dept Mech Engn, Lubbock, TX 79409 USA
[3] Univ Waterloo, Dept Mech & Mechatron Engn, Waterloo, ON N2L 3G1, Canada
[4] Univ Vermont, Dept Orthopaed Rehabil, Burlington, VT 05405 USA
关键词
patellar tendon; graft properties; toe-region; graft initial tension;
D O I
10.1016/j.clinbiomech.2008.03.070
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background. Although the linear elastic (high-load) properties of patellar tendon graft used for anterior cruciate ligament (ACL) reconstruction are studied extensively, the low-load properties of the graft, associated with the toe region of its load-deformation curve, are largely neglected. The objectives of this study were to (i) determine the properties of the patellar tendon in the low-load region and compare to that of the intact ACL, (ii) assess the extent of variability in these properties and relate them to donor factors, and (iii) establish the theoretical importance of low-load properties to the function of the reconstructed knee. Methods. The patellar tendons of 20 unpaired fresh frozen human knees (10 males and 10 females) were harvested. The central portions were trimmed, measured, and tested in tension to failure. The stress-strain curves were fitted with a bi-linear model and the graft properties were measured. Findings. The low-load region modulus of elasticity, E-0, of the patellar tendon, ranged from 49 MPa to 276 MPa in males and 63 MPa to 279 MPa in females. The strain at which the graft transitions from its low-load region to its linear elastic region (epsilon(*) similar to 4.6%) is on average above the strain levels experienced by the ACL during daily activities (epsilon similar to 4%). Donor sex, height and body mass were found to significantly affect some of the mechanical properties of the low-load region. Interpretation. The results suggest that the low-load region properties of the patellar tendon, not the linear elastic properties, govern the biomechanics of the tibiofemoral joint during the early healing period. Also, a wide variability of graft properties in the low-load region exists partly due to certain donor factors. Clinicians should be aware of the low-load region behaviour of the graft and its influence on time = 0 behaviour of the reconstructed knee. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:918 / 925
页数:8
相关论文
共 31 条
  • [1] The effect of initial graft tension on the biomechanical properties of a healing ACL replacement graft: a study in goats
    Abramowitch, SD
    Papageorgiou, CD
    Withrow, JD
    Gilbert, TW
    Woo, SLY
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2003, 21 (04) : 708 - 715
  • [2] The remains of anterior cruciate ligament graft tension after cyclic knee motion
    Arnold, MR
    Lie, DTT
    Verdonschot, N
    de Graaf, R
    Amis, AA
    van Kampen, A
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2005, 33 (04) : 536 - 542
  • [3] The tensile and stress relaxation responses of human patellar tendon varies with specimen cross-sectional area
    Atkinson, TS
    Ewers, BJ
    Haut, RC
    [J]. JOURNAL OF BIOMECHANICS, 1999, 32 (09) : 907 - 914
  • [4] THE RELATIONSHIP BETWEEN ANTERIOR-POSTERIOR KNEE LAXITY AND THE STRUCTURAL-PROPERTIES OF THE PATELLAR TENDON GRAFT - A STUDY IN CANINES
    BEYNNON, BD
    JOHNSON, RJ
    TOYAMA, H
    RENSTROM, PA
    ARMS, SW
    FISCHER, RA
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (06) : 812 - 820
  • [5] The elongation behavior of the anterior cruciate ligament graft in vivo -: A long-term follow-up study
    Beynnon, BD
    Uh, BS
    Johnson, RJ
    Fleming, BC
    Renström, PA
    Nichols, CE
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2001, 29 (02) : 161 - 166
  • [6] BEYNNON BD, 1998, J BIOMECH, V26, P109
  • [7] THE EFFECTS OF DONOR AGE AND STRAIN-RATE ON THE BIOMECHANICAL PROPERTIES OF BONE-PATELLAR TENDON-BONE ALLOGRAFTS
    BLEVINS, FT
    HECKER, AT
    BIGLER, GT
    BOLAND, AL
    HAYES, WC
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 1994, 22 (03) : 328 - 333
  • [8] Effects of initial graft tension on knee stability after anterior cruciate ligament reconstruction using hamstring tendons: A cadaver study
    Boylan, D
    Greis, PE
    West, JR
    Bachus, KN
    Burks, RT
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2003, 19 (07) : 700 - 705
  • [9] Effects of initial graft tension on the tibiofemoral compressive forces and joint position after anterior cruciate ligament reconstruction
    Brady, Mark F.
    Bradley, Michael P.
    Fleming, Braden C.
    Fadale, Paul D.
    Hulstyn, Michael J.
    Banerjee, Rahul
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2007, 35 (03) : 395 - 403
  • [10] EFFECTS OF STRUCTURE AND STRAIN-MEASUREMENT TECHNIQUE ON THE MATERIAL PROPERTIES OF YOUNG HUMAN TENDONS AND FASCIA
    BUTLER, DL
    GROOD, ES
    NOYES, FR
    ZERNICKE, RF
    BRACKETT, K
    [J]. JOURNAL OF BIOMECHANICS, 1984, 17 (08) : 579 - 596