A margin recipe for the management of intra-fraction target motion in radiotherapy

被引:15
作者
Janssen, Tomas M. [1 ]
van der Heide, Uulke A. [1 ]
Remeijer, Peter [1 ]
Sonke, Jan -Jakob [1 ]
van der Bijl, Erik [2 ]
机构
[1] Netherlands Canc Inst, Dept Radiat Oncol, Amsterdam, Netherlands
[2] Radboud Univ Nijmegen, Dept Radiat Oncol, Nijmegen Med Ctr, Nijmegen, Netherlands
来源
PHYSICS & IMAGING IN RADIATION ONCOLOGY | 2022年 / 24卷
关键词
Intra-fraction motion; Treatment margins; Margin recipe; Motion management; ONLINE ADAPTIVE RADIOTHERAPY; TUMOR-TRACKING SYSTEM; PTV MARGINS; SBRT; ACCURACY;
D O I
10.1016/j.phro.2022.11.008
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: Strategies to limit the impact of intra-fraction motion during treatment are common in radiotherapy. Margin recipes, however, are not designed to incorporate these strategies. This work aimed to provide a framework to determine how motion management strategies influence treatment margins. Materials and methods: Two models of intra-fraction motion were considered. In model 1 motion was instanta-neous, before treatment starts and in model 2 motion was a continuous drift during treatment. Motion man-agement strategies were modelled by truncating the underlying error distribution at ca, with a the standard deviation of the distribution and c a free parameter. Using Monte Carlo simulations, we determined how motion management changed the required margin. The analysis was performed for different number of treatment fractions and different standard deviations of the underlying random and systematic errors.Results: The required margin for a continuous drift was found to be well approximated by an average position of the target at3/4 of the drift. Introducing a truncation at ca, the relative change in the margin was equal to 0.3c. This result held for both models, was independent of a or the number of fractions and naturally generalizes to the situation with a residual (systematic) error. Conclusion: Treatment margins can be determined when motion management strategies are applied. Moreover, our analysis can be used to study the potential benefit of different motion management strategies. This allows to discuss and determine the most appropriate strategy for margin reduction.
引用
收藏
页码:159 / 166
页数:8
相关论文
共 50 条
[21]   Intra-fraction displacement of the prostate bed during post-prostatectomy radiotherapy [J].
Linda J. Bell ;
Thomas Eade ;
George Hruby ;
Regina Bromley ;
Andrew Kneebone .
Radiation Oncology, 16
[22]   Ultrasound Imaging to Assess Inter- and Intra-fraction Motion during Bladder Radiotherapy and its Potential as a Verification Tool [J].
McBain, C. A. ;
Green, M. M. ;
Stratford, J. ;
Davies, J. ;
McCarthy, C. ;
Taylor, B. ;
McHugh, D. ;
Swindell, R. ;
Khoo, V. ;
Price, P. .
CLINICAL ONCOLOGY, 2009, 21 (05) :385-393
[23]   Intra-fraction respiratory motion and baseline drift during breast Helical Tomotherapy [J].
Ricotti, Rosalinda ;
Ciardo, Delia ;
Fattori, Giovanni ;
Leonardi, Maria Cristina ;
Morra, Anna ;
Dicuonzo, Samantha ;
Rojas, Damaris ;
Pansini, Floriana ;
Cambria, Raffaella ;
Cattani, Federica ;
Gianoli, Chiara ;
Spinelli, Chiara ;
Riboldi, Marco ;
Baroni, Guido ;
Orecchia, Roberto ;
Jereczek-Fossa, Barbara Alicja .
RADIOTHERAPY AND ONCOLOGY, 2017, 122 (01) :79-86
[24]   Effects of intra-fraction motion on IMRT treatments with low monitor unit segments [J].
Seco, J. ;
Gierga, D. ;
Sharp, G. ;
Turcotte, J. ;
Paganetti, H. .
WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 :1763-+
[25]   Clinical validation of the Varian Truebeam intra-fraction motion review (IMR) system for prostate treatment guidance [J].
Kaur, Guneet ;
Lehmann, Joerg ;
Greer, Peter B. ;
Martin, Jarad ;
Simpson, John .
PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (01) :131-140
[26]   Three-dimensional surface imaging for detection of intra-fraction setup variations during radiotherapy of pelvic tumors [J].
Apicella, Giuseppina ;
Loi, Gianfranco ;
Torrente, Sara ;
Crespi, Silvia ;
Beldi, Debora ;
Brambilla, Marco ;
Krengli, Marco .
RADIOLOGIA MEDICA, 2016, 121 (10) :805-810
[27]   Dosimetry implications of VMAT delivery angles and intra-fraction motion for SBRT prostate treatments [J].
Dimiskovski, Dimitrij ;
Aland, Trent .
MEDICAL DOSIMETRY, 2023, 48 (04) :249-255
[28]   Quantification of intra-fraction changes during radiotherapy of cervical cancer assessed with pre- and post-fraction Cone Beam CT scans [J].
Heijkoop, Sabrina T. ;
Langerak, Thomas R. ;
Quint, Sandra ;
Mens, Jan Willem M. ;
Zolnay, Andras G. ;
Heijmen, Ben J. M. ;
Hoogeman, Mischa S. .
RADIOTHERAPY AND ONCOLOGY, 2015, 117 (03) :536-541
[29]   Evaluation of inter- and intra-fraction 6D motion for stereotactic body radiation therapy of spinal metastases: influence of treatment time [J].
Henni, Ahmed Hadj ;
Gensanne, David ;
Roge, Maximilien ;
Hanzen, Chantal ;
Bulot, Guillaume ;
Colard, Elyse ;
Thureau, Sebastien .
RADIATION ONCOLOGY, 2021, 16 (01)
[30]   Feasibility of a TPS-integrated method to incorporate tumor motion in the margin recipe [J].
Dechambre, David ;
Vander Veken, Loic ;
Delor, Antoine ;
Sterpin, Edmond ;
Vanneste, Francoise ;
Geets, Xavier .
MEDICAL DOSIMETRY, 2021, 46 (03) :253-258