Task Force Report: Scales for Screening and Evaluating Tremor Critique and Recommendations

被引:135
作者
Elble, Rodger [1 ]
Bain, Peter [2 ]
Forjaz, Maria Joao [3 ]
Haubenberger, Dietrich [4 ]
Testa, Claudia [5 ]
Goetz, Christopher G. [6 ]
Leentjens, Albert F. G. [7 ]
Martinez-Martin, Pablo [8 ,9 ]
Pavy-Le Traon, Anne [10 ]
Post, Bart [11 ]
Sampaio, Cristina [12 ,13 ]
Stebbins, Glenn T. [6 ]
Weintraub, Daniel [14 ]
Schrag, Anette [15 ]
机构
[1] So Illinois Univ, Sch Med, Dept Neurol, Springfield, IL 62794 USA
[2] Univ London Imperial Coll Sci Technol & Med, Charing Cross Hosp, Dept Neurol, London, England
[3] Carlos III Inst Hlth, Natl Sch Publ Hlth & Red Invest Serv Sanit & Enfe, Madrid, Spain
[4] Med Univ Vienna, Dept Neurol, Vienna, Austria
[5] Virginia Commonwealth Univ, Dept Neurol, Richmond, VA USA
[6] Rush Univ, Med Ctr, Dept Neurol Sci, Chicago, IL 60612 USA
[7] Maastricht Univ, Med Ctr, Dept Psychiat, Maastricht, Netherlands
[8] Carlos III Inst Hlth, Alzheimer Ctr Reina Sofia Fdn, Madrid, Spain
[9] Carlos III Inst Hlth, Ctr Invest Biomed Red Enfermedades Neurodegenerat, Madrid, Spain
[10] Univ Hosp Toulouse, Hop Purpan, Dept Neurol, Toulouse, France
[11] Radboud Univ Nijmegen, Med Ctr, Dept Neurol, NL-6525 ED Nijmegen, Netherlands
[12] CHDI Fdn, Princeton, NJ USA
[13] Univ Lisbon, Inst Mol Med, P-1699 Lisbon, Portugal
[14] Univ Penn, Perelman Sch Med, Dept Psychiat, Philadelphia, PA 19104 USA
[15] UCL, Inst Neurol, London, England
关键词
tremor; rating scales; reliability; validity; sensitivity; TEST-RETEST RELIABILITY; DEEP BRAIN-STIMULATION; QUALITY-OF-LIFE; DOUBLE-BLIND; RATING-SCALE; MULTIPLE-SCLEROSIS; DETECTABLE CHANGE; VALIDITY; PLACEBO; QUESTIONNAIRE;
D O I
10.1002/mds.25648
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The Movement Disorder Society established a task force to review rating scales for the assessment of tremor. Screening instruments used in identifying patients with tremor were also reviewed. Seven tremor severity scales, six activities of daily living (ADL)/disability scales, four quality-of-life scales, and five screening instruments were identified by searching PubMed.gov. The availability, use, acceptability, reliability, validity, and sensitivity to change were reviewed for each scale; and each scale was classified as recommended, suggested or listed based on whether 3, 2, or 1 of the following criteria were met: (1) used in the assessment of tremor (yes/no), (2) used in published studies by people other than the developers (yes/no), and (3) successful clinimetric testing (yes/no). Five tremor severity scales (the Fahn-Tolosa-Marin Tremor Rating Scale, the Bain and Findley Clinical Tremor Rating Scale, the Bain and Findley Spirography Scale, the Washington Heights-Inwood Genetic Study of Essential Tremor Rating Scale, and the Tremor Research Group Essential Tremor Rating Assessment Scale), one ADL/disability scale (the Bain and Findley Tremor ADL Scale), one quality-of-life scale (the Quality of Life in Essential Tremor Questionnaire), and one screening instrument (the Washington Heights-Inwood Genetic Study of Essential Tremor Rating Scale, version 1) are recommended using these criteria. However, all scales need a more comprehensive analysis of sensitivity to change in order to judge their utility in clinical trials and individual patient assessments. The task force recommends that further work with existing recommended scales be performed as opposed to the development of new tremor scales. (c) 2013 International Parkinson and Movement Disorder Society
引用
收藏
页码:1793 / 1800
页数:8
相关论文
共 61 条
[11]   HOW MUCH CHANGE IS TRUE CHANGE? THE MINIMUM DETECTABLE CHANGE OF THE BERG BALANCE SCALE IN ELDERLY PEOPLE [J].
Donoghue, Declan ;
Stokes, Emma K. .
JOURNAL OF REHABILITATION MEDICINE, 2009, 41 (05) :343-346
[12]  
Elble R., 2002, Neuromuscular function and disease: basic, clinical and electrodiagnostic aspects, P1759
[13]   Characteristics of physiologic tremor in young and elderly adults [J].
Elble, RJ .
CLINICAL NEUROPHYSIOLOGY, 2003, 114 (04) :624-635
[14]   PHYSIOLOGICAL AND ESSENTIAL TREMOR [J].
ELBLE, RJ .
NEUROLOGY, 1986, 36 (02) :225-231
[15]   Reliability of a new scale for essential tremor [J].
Elble, Rodger ;
Comella, Cynthia ;
Fahn, Stanley ;
Hallett, Mark ;
Jankovic, Joseph ;
Juncos, Jorge L. ;
LeWitt, Peter ;
Lyons, Kelly ;
Ondo, William ;
Pahwa, Rajesh ;
Sethi, Kapil ;
Stover, Natividad ;
Tarsy, Daniel ;
Testa, Claudia ;
Tintner, Ron ;
Watts, Ray ;
Zesiewicz, Theresa .
MOVEMENT DISORDERS, 2012, 27 (12) :1567-1569
[16]   Levetiracetam is not effective for essential tremor [J].
Elble, Rodger J. ;
Lyons, Kelly E. ;
Pahwa, Rajesh .
CLINICAL NEUROPHARMACOLOGY, 2007, 30 (06) :350-356
[17]   Tremor amplitude is logarithmically related to 4-and 5-point tremor rating scales [J].
Elble, Rodger J. ;
Pullman, Seth L. ;
Matsumoto, Joseph Y. ;
Raethjen, Jan ;
Deuschl, Guenther ;
Tintner, Ron .
BRAIN, 2006, 129 :2660-2666
[18]  
Fahn S, 1993, PARKINSONS DIS MOVEM, P225
[19]  
Fahn S., 1988, PARKINSONS DIS MOVEM, P225
[20]   A pilot tolerability and efficacy trial of sodium oxybate in ethanol-responsive movement disorders [J].
Frucht, SJ ;
Bordelon, Y ;
Houghton, WH ;
Reardan, D .
MOVEMENT DISORDERS, 2005, 20 (10) :1330-1337