Dual-energy x-ray absorptiometry measurement and accuracy of bone mineral after unilateral total hip arthroplasty

被引:11
作者
Bloebaum, Roy D.
Liau, Derek W.
Lester, D. Kevin
Rosenbaum, Teri G.
机构
[1] Salt Lake City Vet Adm Hlth Care Syst, Bone & Joint Res Lab 151F, Salt Lake City, UT 84148 USA
[2] Univ Utah, Dept Bioengn, Salt Lake City, UT 84112 USA
[3] Univ Utah, Sch Med, Dept Orthoped Surg, Salt Lake City, UT 84112 USA
[4] Univ Washington, Sch Med, Seattle, WA 98195 USA
[5] Calif State Univ San Francisco Fresno, Dept Orthoped, Fresno, CA USA
关键词
dual-energy x-ray absorptiometry; total hip arthroplasty; DEXA accuracy; bone remodeling;
D O I
10.1016/j.arth.2005.11.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The standard technique for monitoring bone mineral in hip arthroplasty has been dual-energy x-ray absorptiometry (DEXA). The accuracy of DEXA in the cortical bone adjacent to femoral components has not been established. This study evaluated bone mineral in the cortical bone adjacent to the femoral component comparing DEXA and ashing. Seven pairs of human femora from postmortem donors with unilateral hip implants were examined. Twenty-eight ashed core specimens from both the medial and lateral sides were taken. Cortical bone loss was seen to be greater in the proximal and medial regions of the implanted femora. Dual-energy x-ray absorptiometry failed to show an acceptable level of accuracy compared with ash data (r = 0.56; P =.002). it did show relative patterns of bone loss. Bone loss was consistent with implant-induced stress shielding.
引用
收藏
页码:612 / 622
页数:11
相关论文
共 36 条
[1]   Determining mineral content variations in bone using backscattered electron imaging [J].
Bloebaum, RD ;
Skedros, JG ;
Vajda, EG ;
Bachus, KN ;
Constantz, BR .
BONE, 1997, 20 (05) :485-490
[2]  
BOBYN JD, 1992, CLIN ORTHOP RELAT R, P79
[3]   CT of the middiaphyseal femur: Cortical bone mineral density and relation to porosity [J].
Bousson, V ;
Bergot, C ;
Meunier, A ;
Barbot, F ;
Parlier-Cuau, C ;
Laval-Jeantet, AM ;
Laredo, JD .
RADIOLOGY, 2000, 217 (01) :179-187
[4]   ACCURACY OF DEXA MEASUREMENT OF BONE-MINERAL DENSITY AFTER TOTAL HIP-ARTHROPLASTY [J].
COHEN, B ;
RUSHTON, N .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1995, 77B (03) :479-483
[5]   BONE DENSITOMETRY IN CLINICAL-PRACTICE [J].
COMPSTON, JE ;
COOPER, C ;
KANIS, JA .
BRITISH MEDICAL JOURNAL, 1995, 310 (6993) :1507-1510
[7]   MECHANICAL CONSEQUENCES OF VARIATION IN MINERAL CONTENT OF BONE [J].
CURREY, JD .
JOURNAL OF BIOMECHANICS, 1969, 2 (01) :1-+
[9]   The effects of ageing and changes in mineral content in degrading the toughness of human femora [J].
Currey, JD ;
Brear, K ;
Zioupos, P .
JOURNAL OF BIOMECHANICS, 1996, 29 (02) :257-260
[10]   MECHANICAL-PROPERTIES OF BONE TISSUES WITH GREATLY DIFFERING FUNCTIONS [J].
CURREY, JD .