Study of Ge-As-Se system with high refractive index for infrared glass molded lens

被引:0
作者
Kim, Seon Hoon [1 ]
Lee, Taeyeon [1 ]
Kim, Soyoung [1 ]
Han, Karam [1 ]
In, Jung-Hwan [1 ]
Kim, Doo Gun [1 ]
Choi, Ju Hyeon [1 ]
机构
[1] Korea Photon Technol Inst, Opt Lens Mat Res Ctr, Gwangju 61007, South Korea
来源
INFRARED SENSORS, DEVICES, AND APPLICATIONS XII | 2022年 / 12234卷
关键词
chalcogenide; Ge-As-Se; glass materials; refractive index; dispersion; infrared; molded lens;
D O I
10.1117/12.2632956
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
For chalcogenide-based infrared glass materials, the need was emphasized along with the spread of thermal imaging cameras in COVID 19 environment. Commercial Ge-As-Se glass system exhibits a dispersion value of 100 similar to 180 and a refractive index of 2.5 or more, and is suitable for the glass molding process, so it is used as an aspherical infrared lens for various thermal imaging cameras. However, some compositions are not suitable for glass molding process. In this study, the composition of the long wavelength infrared glass melting was designed based on the Ge-As-Se system with a Ge composition range of 0 similar to 35 at%, As composition range of 20 similar to 40 at%, and Se composition range of 25 similar to 60 at%. As a result of XRD analysis for each Ge-As-Se-based composition, it was confirmed that all amorphous grains were obtained in the developed composition area. For the Ge-As-Se glass-forming composition region, the glass transition temperature ranged from 180 to 425 degrees C. The refractive index was measured using the prism method in the 3 to 12 mu m wavelength band. The refractive index (lambda=10 mu m) of Ge5As40Se55 and Ge5As35Se60 was 2.6913 and 2.6538, respectively. Moldability test was performed using a glass molding press. As a result of observing whether the lens has internal defects and microcracks after molding, it was confirmed that there was no abnormality and that it was suitable for glass molding process.
引用
收藏
页数:7
相关论文
共 8 条
[1]   Refractive Index and Thermo-Optic Coefficients of Ge-As-Se Chalcogenide Glasses [J].
Gleason, Benn ;
Richardson, Kathleen ;
Sisken, Laura ;
Smith, Charmayne .
INTERNATIONAL JOURNAL OF APPLIED GLASS SCIENCE, 2016, 7 (03) :374-383
[2]  
HILTON AR, 1966, PHYS CHEM GLASSES, V7, P105
[3]  
Savage J. A., 1985, INFRARED OPTICAL MAT, P100
[4]   The environment has effects on infrared temperature screening for COVID-19 infection [J].
Spindel, Jeffrey F. ;
Pokrywa, Stephen ;
Elder, Nathan ;
Smith, Clayton .
AMERICAN JOURNAL OF INFECTION CONTROL, 2021, 49 (11) :1445-1447
[5]  
Varshneya A. K., 2013, Fundamentals of Inorganic Glasses
[6]   Thermal characterization of Ge-As-Se glasses by differential scanning calorimetry [J].
Wang, R. P. ;
Zha, C. J. ;
Rode, A. V. ;
Madden, S. J. ;
Luther-Davies, B. .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN ELECTRONICS, 2007, 18 (Suppl 1) :S419-S422
[7]   Raman spectra of GexAsySe1-x-y glasses [J].
Wang, R. P. ;
Smith, A. ;
Prasad, A. ;
Choi, D. Y. ;
Luther-Davies, B. .
JOURNAL OF APPLIED PHYSICS, 2009, 106 (04)
[8]   A Review of the Precision Glass Molding of Chalcogenide Glass (ChG) for Infrared Optics [J].
Zhou, Tianfeng ;
Zhu, Zhanchen ;
Liu, Xiaohua ;
Liang, Zhiqiang ;
Wang, Xibin .
MICROMACHINES, 2018, 9 (07)