Dynamic CT myocardial perfusion imaging: performance of 3D semi-automated evaluation software

被引:34
作者
Ebersberger, Ullrich [1 ,2 ]
Marcus, Roy P. [3 ]
Schoepf, U. Joseph [1 ]
Lo, Gladys G. [4 ]
Wang, Yining [1 ,5 ]
Blanke, Philipp [1 ,6 ]
Geyer, Lucas L. [1 ,3 ]
Gray, J. Cranston, III [1 ]
McQuiston, Andrew D. [1 ]
Cho, Young Jun [1 ,8 ]
Scheuering, Michael [7 ]
Canstein, Christian [7 ]
Nikolaou, Konstantin [3 ]
Hoffmann, Ellen [2 ]
Bamberg, Fabian [3 ]
机构
[1] Med Univ S Carolina, Heart & Vasc Ctr, Charleston, SC 29425 USA
[2] Heart Ctr Munich Bogenhausen, Dept Cardiol & Intens Care Med, Munich, Germany
[3] Univ Munich, Inst Clin Radiol, Munich, Germany
[4] Hong Kong Sanat & Hosp, Dept Diagnost & Intervent Radiol, Happy Valley, Hong Kong, Peoples R China
[5] Chinese Acad Med Sci, Peking Union Med Coll Hosp, Dept Radiol, Beijing 100730, Peoples R China
[6] Univ Hosp Freiburg, Dept Diagnost Radiol, Freiburg, Germany
[7] Siemens Healthcare, CT Div, Forchheim, Germany
[8] Konyang Univ Coll Med, Dept Radiol, Taejon, South Korea
关键词
Adenosine stress; Myocardial perfusion imaging; Automated software; Computed tomography; Technical efficacy; CARDIOVASCULAR MAGNETIC-RESONANCE; EMISSION COMPUTED-TOMOGRAPHY; CORONARY-ARTERY-DISEASE; DUAL-SOURCE CT; SPECT; ANGIOGRAPHY; HEART; SEGMENTATION; ISCHEMIA;
D O I
10.1007/s00330-013-2997-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives To evaluate the performance of three-dimensional semi-automated evaluation software for the assessment of myocardial blood flow (MBF) and blood volume (MBV) at dynamic myocardial perfusion computed tomography (CT). Methods Volume-based software relying on marginal space learning and probabilistic boosting tree-based contour fitting was applied to CT myocardial perfusion imaging data of 37 subjects. In addition, all image data were analysed manually and both approaches were compared with SPECT findings. Study endpoints included time of analysis and conventional measures of diagnostic accuracy. Results Of 592 analysable segments, 42 showed perfusion defects on SPECT. Average analysis times for the manual and software-based approaches were 49.1 +/- 11.2 and 16.5 +/- 3.7 min respectively (P<0.01). There was strong agreement between the two measures of interest (MBF, ICC=0.91, and MBV, ICC=0.88, both P<0.01) and no significant difference in MBF/MBV with respect to diagnostic accuracy between the two approaches for both MBF and MBV for manual versus software-based approach; respectively; all comparisons P>0.05. Conclusions Three-dimensional semi-automated evaluation of dynamic myocardial perfusion CT data provides similar measures and diagnostic accuracy to manual evaluation, albeit with substantially reduced analysis times. This capability may aid the integration of this test into clinical workflows. Key Points Myocardial perfusion CT is attractive for comprehensive coronary heart disease assessment. Traditional image analysis methods are cumbersome and time-consuming. Automated 3D perfusion software shortens analysis times. Automated 3D perfusion software increases standardisation of myocardial perfusion CT. Automated, standardised analysis fosters myocardial perfusion CT integration into clinical practice.
引用
收藏
页码:191 / 199
页数:9
相关论文
共 18 条
[1]   Detection of Hemodynamically Significant Coronary Artery Stenosis: Incremental Diagnostic Value of Dynamic CT-based Myocardial Perfusion Imaging [J].
Bamberg, Fabian ;
Becker, Alexander ;
Schwarz, Florian ;
Marcus, Roy P. ;
Greif, Martin ;
von Ziegler, Franz ;
Blankstein, Ron ;
Hoffmann, Udo ;
Sommer, Wieland H. ;
Hoffmann, Verena S. ;
Johnson, Thorsten R. C. ;
Becker, Hans-Christoph R. ;
Wintersperger, Bernd J. ;
Reiser, Maximilian F. ;
Nikolaou, Konstantin .
RADIOLOGY, 2011, 260 (03) :689-698
[2]   Adenosine-Stress Dynamic Myocardial CT Perfusion Imaging Initial Clinical Experience [J].
Bastarrika, Gorka ;
Ramos-Duran, Luis ;
Rosenblum, Michael A. ;
Kang, Doo Kyoung ;
Rowe, Garrett W. ;
Schoepf, U. Joseph .
INVESTIGATIVE RADIOLOGY, 2010, 45 (06) :306-313
[3]   CT of Coronary Artery Disease [J].
Bastarrika, Gorka ;
Lee, Yeong Shyan ;
Huda, Walter ;
Ruzsics, Balazs ;
Costello, Philip ;
Schoepf, U. Joseph .
RADIOLOGY, 2009, 253 (02) :317-338
[4]   Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: Comparison with ECG-gated Tc-99m sestamibi SPECT [J].
Bateman, TM ;
Heller, GV ;
McGhie, AI ;
Friedman, JD ;
Case, JA ;
Bryngelson, JR ;
Hertenstein, GK ;
Moutray, KL ;
Reid, K ;
Cullom, SJ .
JOURNAL OF NUCLEAR CARDIOLOGY, 2006, 13 (01) :24-33
[5]   Adenosine-Induced Stress Myocardial Perfusion Imaging Using Dual-Source Cardiac Computed Tomography [J].
Blankstein, Ron ;
Shturman, Leon D. ;
Rogers, Ian S. ;
Rocha-Filho, Jose A. ;
Okada, David R. ;
Sarwar, Ammar ;
Soni, Anand V. ;
Bezerra, Hiram ;
Ghoshhajra, Brian B. ;
Petranovic, Milena ;
Loureiro, Ricardo ;
Feuchtner, Gudrun ;
Gewirtz, Henry ;
Hoffmann, Udo ;
Mamuya, Wilfred S. ;
Brady, Thomas J. ;
Cury, Ricardo C. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (12) :1072-1084
[6]  
Bruder H, 2009, MED IMAGING, V7258, P57
[7]   Standardized myocardial segmentation and nomenclature for tomographic imaging of the heart - A statement for healthcare professionals from the Cardiac Imaging Committee of the Council on Clinical Cardiology of the American Heart Association [J].
Cerqueira, MD ;
Weissman, NJ ;
Dilsizian, V ;
Jacobs, AK ;
Kaul, S ;
Laskey, WK ;
Pennell, DJ ;
Rumberger, JA ;
Ryan, T ;
Verani, MS .
CIRCULATION, 2002, 105 (04) :539-542
[8]   Evaluation of myocardial CT perfusion in patients presenting with acute chest pain to the emergency department: comparison with SPECT-myocardial perfusion imaging [J].
Feuchtner, Gudrun Maria ;
Plank, Fabian ;
Pena, Constantino ;
Battle, Juan ;
Min, James ;
Leipsic, Jonathon ;
Labounty, Troy ;
Janowitz, Warren ;
Katzen, Barry ;
Ziffer, Jack ;
Cury, Ricardo C. .
HEART, 2012, 98 (20) :1510-1517
[9]   Adenosine Stress 64- and 256-Row Detector Computed Tomography Angiography and Perfusion Imaging A Pilot Study Evaluating the Transmural Extent of Perfusion Abnormalities to Predict Atherosclerosis Causing Myocardial Ischemia [J].
George, Richard T. ;
Arbab-Zadeh, Armin ;
Miller, Julie M. ;
Kitagawa, Kakuya ;
Chang, Hyuk-Jae ;
Bluemke, David A. ;
Becker, Lewis ;
Yousuf, Omair ;
Texter, John ;
Lardo, Albert C. ;
Lima, Joao A. C. .
CIRCULATION-CARDIOVASCULAR IMAGING, 2009, 2 (03) :174-182
[10]   Cardiovascular magnetic resonance and single-photon emission computed tomography for diagnosis of coronary heart disease (CE-MARC): a prospective trial [J].
Greenwood, John P. ;
Maredia, Neil ;
Younger, John F. ;
Brown, Julia M. ;
Nixon, Jane ;
Everett, Colin C. ;
Bijsterveld, Petra ;
Ridgway, John P. ;
Radjenovic, Aleksandra ;
Dickinson, Catherine J. ;
Ball, Stephen G. ;
Plein, Sven .
LANCET, 2012, 379 (9814) :453-460