Refractive stability of a new single-piece hydrophobic acrylic intraocular lens and corneal wound repair after implantation using a new automated intraocular lens delivery system

被引:14
作者
Negishi, Kazuno [1 ]
Masui, Sachiko [1 ]
Torii, Hidemasa [1 ]
Nishi, Yasuyo [1 ]
Tsubota, Kazuo [1 ]
机构
[1] Keio Univ, Dept Ophthalmol, Sch Med, Tokyo, Japan
关键词
INCISION; PHACOEMULSIFICATION;
D O I
10.1371/journal.pone.0238366
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To investigate refractive stability and characterize corneal incision repair up to 3 months after implantation of a new hydrophobic acrylic intraocular lens (IOL) with hydroxyethylmethacrylate using a new automated IOL delivery system. Methods This prospective case series included 50 eyes of 50 patients undergoing phacoemulsification and implantation of the Clareon(R)CNA0T0 IOL using the AutonoMe(R)automated delivery system in the Department of Ophthalmology, Keio University School of Medicine. The clinical data were collected from 46 eyes of 46 patients preoperatively and 1 day, 1 week, and 1 and 3 months postoperatively. Endothelial-side incision gaping, posterior incision retraction, and Descemet's membrane detachment were recorded as present or absent using anterior-segment optical coherence tomography postoperatively. Results The uncorrected distance and corrected distance visual acuities improved and stabilized 1 week postoperatively. The anterior chamber depth was stable from 1 week postoperatively. The subjective refraction was stable from 1 day postoperatively. Descemet's membrane detachments and endothelial-side wound gaping were seen in 19 (41.3%) eyes and 34 (73.9%) eyes 1 day postoperatively and decreased gradually. Posterior incision retraction was seen in eight eyes (17.4%) on day 1 and increased to 19 eyes (41.3%) 3 months postoperatively. Conclusions The Clareon IOL had excellent refractive stability from day 1 postoperatively. The AutonoMe automated delivery system enables safe IOL implantation through a 2.4-mm corneal incision, although the wound required longer than 1 month to heal postoperatively.
引用
收藏
页数:9
相关论文
共 23 条
[1]   Clinical experience with the Clareon® IOL and the AutonoMe® implantation system [J].
Bedar, Mohammad Seleman ;
Kellner, Ulrich .
OPHTHALMOLOGE, 2020, 117 (11) :1100-1104
[2]   Biomechanical and optical properties of 2 new hydrophobic platforms for intraocular lenses [J].
Bozukova, Dimitriya ;
Pagnoulle, Christophe ;
Jerome, Christine .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (09) :1404-1414
[3]   Comparison of clear corneal incision injuries between torsional and conventional phacoemulsification [J].
Chen, Xu ;
Ji, Yinghong ;
Lu, Yi .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (09) :2147-2154
[4]   Surface properties of commercially available hydrophobic acrylic intraocular lenses: Comparative study [J].
De Giacinto, Chiara ;
Porrelli, Davide ;
Turco, Gianluca ;
Pastore, Marco Rocco ;
D'Aloisio, Rossella ;
Tognetto, Daniele .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (09) :1330-1334
[5]   Anatomy and physiology of the cornea [J].
DelMonte, Derek W. ;
Kim, Terry .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2011, 37 (03) :588-598
[6]   Comparison of the stability of 1-piece and 3-piece acrylic intraocular lenses in the lens capsule [J].
Hayashi, K ;
Hayashi, H .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (02) :337-342
[7]   Evaluation of posterior capsule opacification of the Alcon Clareon IOL vs the Alcon Acrysof IOL using a human capsular bag model [J].
Hillenmayer, Anna ;
Wertheimer, Christian M. ;
Kassumeh, Stefan ;
von Studnitz, Annabel ;
Luft, Nikolaus ;
Ohlmann, Andreas ;
Priglinger, Siegfried ;
Mayer, Wolfgang J. .
BMC OPHTHALMOLOGY, 2020, 20 (01)
[8]   Comparison of the biomechanical behavior of foldable intraocular lenses [J].
Lane, SS ;
Burgi, P ;
Millos, GS ;
Orchowski, MW ;
Vaughan, M ;
Schwarte, E .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (11) :2397-2402
[9]   Evaluation of intraocular lens mechanical stability [J].
Lane, Stephen ;
Collins, Stephen ;
Das, Kamal K. ;
Maass, Sean ;
Thatthamla, Israwal ;
Schatz, Hillary ;
Van Noy, Stephen ;
Jain, Rakhi .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (04) :501-506
[10]   Effect of phacoemulsification incision size on incision repair and remodeling: Optical coherence tomography assessment [J].
Li, Sunny S. ;
Misra, Stuti L. ;
Wallace, Henry B. ;
McKelvie, James .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (11) :1336-1343