Screening for stereopsis without the use of technical equipment: Scale development and cross-validation

被引:8
作者
Coren, S [1 ]
Hakstian, AR [1 ]
机构
[1] UNIV BRITISH COLUMBIA, DEPT PSYCHOL, VANCOUVER, BC V6T 1Z4, CANADA
基金
加拿大自然科学与工程研究理事会; 英国医学研究理事会;
关键词
stereopsis; vision testing; binocular vision; sensory deficits;
D O I
10.1093/ije/25.1.146
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background. Although adequate stereopsis is important for many common sensory-motor activities, large-scale normative samples of the relationship between stereopsis and other individual difference variables are relatively scarce, and stereopsis is often not routinely tested even in settings where it might play an important role, This is, in part, due to the fact that data collection requires individual testing, the use of costly technical equipment and trained personnel. Method Beginning with a pool of 161 items and an initial sample of 542 individuals, we developed a self-report inventory-suitable for group testing, survey administration or rapid individual screening-possessing a high correlation with laboratory measures of stereopsis. The inventory was then cross-validated against laboratory measures of stereo-acuity in a separate sample of 573 subjects. Results. For the combined samples, the resulting 10-item Stereopsis Screening Inventory (SSI) correlated with laboratory measures of per cent stereopsis (r = 0.80). The inventory's reliability was assessed with a resulting internal consistency coefficient (alpha) of 0.88. Conclusions. The SSI provides a fast, valid and inexpensive measure of uncorrected stereopsis which can be used for rapid screening or epidemiological surveys. The correct classification rate for the SSI was 84% for a low fence requiring 65% stereopsis or better, and 81% for a high fence of residual stereopsis of 25% or less. A conversion equation, with estimated variability is also provided for point estimates of per cent stereopsis from the SSI scores. A copy of the inventory and scoring procedure is given in the Appendix.
引用
收藏
页码:146 / 152
页数:7
相关论文
共 19 条
[1]  
Amos JF, 1987, DIAGNOSIS MANAGEMENT
[2]   THE NATURE OF THE DATA, OR HOW TO CHOOSE A CORRELATION-COEFFICIENT [J].
CARROLL, JB .
PSYCHOMETRIKA, 1961, 26 (04) :347-372
[3]   THE DEVELOPMENT AND CROSS-VALIDATION OF A SELF-REPORT INVENTORY TO ASSESS PURE-TONE THRESHOLD HEARING SENSITIVITY [J].
COREN, S ;
HAKSTIAN, AR .
JOURNAL OF SPEECH AND HEARING RESEARCH, 1992, 35 (04) :921-928
[4]   VALIDATION OF A SELF-REPORT INVENTORY FOR THE MEASUREMENT OF VISUAL-ACUITY [J].
COREN, S ;
HAKSTIAN, AR .
INTERNATIONAL JOURNAL OF EPIDEMIOLOGY, 1989, 18 (02) :451-456
[5]   VISUAL SCREENING WITHOUT THE USE OF TECHNICAL EQUIPMENT - PRELIMINARY DEVELOPMENT OF A BEHAVIORALLY VALIDATED QUESTIONNAIRE [J].
COREN, S ;
HAKSTIAN, AR .
APPLIED OPTICS, 1987, 26 (08) :1468-1472
[6]  
COREN S, 1987, AM J OPTOM PHYS OPT, V64, P897
[7]   COLOR-VISION SCREENING WITHOUT THE USE OF TECHNICAL EQUIPMENT - SCALE DEVELOPMENT AND CROSS-VALIDATION [J].
COREN, S ;
HAKSTIAN, AR .
PERCEPTION & PSYCHOPHYSICS, 1988, 43 (02) :115-120
[8]  
Coren S., 1994, Sensation and perception, V4th ed.
[9]  
CORSO JF, 1971, AGING SENSORY SYSTEM
[10]  
Cronbach L.J., 1984, ESSENTIALS PSYCHOL T