Development of a four-axis moving phantom for patient-specific QA of surrogate signal-based tracking IMRT

被引:14
|
作者
Mukumoto, Nobutaka [1 ]
Nakamura, Mitsuhiro [1 ]
Yamada, Masahiro [1 ]
Takahashi, Kunio [2 ]
Akimoto, Mami [1 ]
Miyabe, Yuki [1 ]
Yokota, Kenji [1 ]
Kaneko, Shuji [1 ]
Nakamura, Akira [1 ]
Itasaka, Satoshi [3 ]
Matsuo, Yukinori [1 ]
Mizowaki, Takashi [1 ]
Kokubo, Masaki [4 ,5 ]
Hiraoka, Masahiro [1 ]
机构
[1] Kyoto Univ, Grad Sch Med, Dept Radiat Oncol & Image Appl Therapy, Kyoto 6068507, Japan
[2] Mitsubishi Heavy Ind Co Ltd, Hiroshima 7338553, Japan
[3] Kurashiki Cent Hosp, Dept Radiol, Kurashiki, Okayama 7108602, Japan
[4] Kobe City Med Ctr, Dept Radiat Oncol, Gen Hosp, Kobe, Hyogo 6500047, Japan
[5] Inst Biomed Res & Innovat, Div Radiat Oncol, Kobe, Hyogo 6500047, Japan
关键词
four-axis moving phantom; motion management; tracking; IMRT; patient-specific quality assurance; TUMOR-TRACKING; BREATH-HOLD; MOTION; RADIOTHERAPY; ACCURACY; SYSTEM; PARAMETERS; MANAGEMENT; DELIVERY; CANCER;
D O I
10.1118/1.4966130
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The purposes of this study were two-fold: first, to develop a four-axis moving phantom for patient-specific quality assurance (QA) in surrogate signal-based dynamic tumor-tracking intensity-modulated radiotherapy (DTT-IMRT), and second, to evaluate the accuracy of the moving phantom and perform patient-specific dosimetric QA of the surrogate signal-based DTT-IMRT. Methods: The four-axis moving phantom comprised three orthogonal linear actuators for target motion and a fourth one for surrogate motion. The positional accuracy was verified using four laser displacement gauges under static conditions (+/- 40 mm displacements along each axis) and moving conditions [eight regular sinusoidal and fourth-power-of-sinusoidal patterns with peak-to-peak motion ranges (H) of 10-80 mm and a breathing period (T) of 4 s, and three irregular respiratory patterns with H of 1.4-2.5 mm in the left-right, 7.7-11.6 mm in the superior-inferior, and 3.1-4.2 mm in the anterior-posterior directions for the target motion, and 4.8-14.5 mm in the anterior-posterior direction for the surrogate motion, and T of 3.9-4.9 s]. Furthermore, perpendicularity, defined as the vector angle between any two axes, was measured using an optical measurement system. The reproducibility of the uncertainties in DTT-IMRT was then evaluated. Respiratory motions from 20 patients acquired in advance were reproduced and compared three-dimensionally with the originals. Furthermore, patient-specific dosimetric QAs of DTT-IMRT were performed for ten pancreatic cancer patients. The doses delivered to Gafchromic films under tracking and moving conditions were compared with those delivered under static conditions without dose normalization. Results: Positional errors of the moving phantom under static and moving conditions were within 0.05 mm. The perpendicularity of the moving phantom was within 0.2 degrees of 90 degrees. The differences in prediction errors between the original and reproduced respiratory motions were -0.1 +/- 0.1 mm for the lateral direction, -0.1 +/- 0.2 mm for the superior-inferior direction, and -0.1 +/- 0.1 mm for the anterior-posterior direction. The dosimetric accuracy showed significant improvements, of 92.9% +/- 4.0% with tracking versus 69.8% +/- 7.4% without tracking, in the passing rates of. with the criterion of 3%/1 mm (p < 0.001). Although the dosimetric accuracy of IMRT without tracking showed a significant negative correlation with the 3D motion range of the target (r = -0.59, p < 0.05), there was no significant correlation for DTT-IMRT (r = 0.03, p = 0.464). Conclusions: The developed four-axis moving phantom had sufficient accuracy to reproduce patient respiratory motions, allowing patient-specific QA of the surrogate signal-based DTT-IMRT under realistic conditions. Although IMRT without tracking decreased the dosimetric accuracy as the target motion increased, the DTT-IMRT achieved high dosimetric accuracy. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:6364 / 6374
页数:11
相关论文
共 4 条
  • [1] Correlation of phantom-based and log file patient-specific QA with complexity scores for VMAT
    Agnew, Christina E.
    Irvine, Denise M.
    McGarry, Conor K.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (06): : 204 - 216
  • [2] 2D dose reconstruction of IMRT patient-specific QA based on log file
    Mubarok, Sayid
    Wahyu, Wibowo Edy
    Supriyanto, Pawiro Ardjo
    RADIATION PHYSICS AND CHEMISTRY, 2020, 166
  • [3] A single-optical kernel for a phosphor-screen-based geometric QA system (RavenQA™) as a tool for patient-specific IMRT/VMAT QA
    Lee, Minsik
    Ding, Kai
    Yi, ByongYong
    PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (20):
  • [4] A novel dynamic robotic moving phantom system for patient-specific quality assurance in real-time tumor-tracking radiotherapy
    Shiinoki, Takehiro
    Fujii, Fumitake
    Fujimoto, Koya
    Yuasa, Yuki
    Sera, Tatsuhiro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (07): : 16 - 28