Evaluation of Cervical Elastography Strain Pattern to Predict Preterm Birth

被引:16
作者
Gesthuysen, Anna [1 ]
Hammer, Kerstin [1 ]
Moellers, Mareike [1 ]
Braun, Janina [1 ]
de Murcia, Kathrin Oelmeier [1 ]
Falkenberg, Maria Karina [1 ]
Koester, Helen Ann [1 ]
Moellmann, Ute [1 ]
Fruscalzo, Arrigo [2 ]
Bormann, Eike [3 ]
Klockenbusch, Walter [1 ]
Schmitz, Ralf [1 ]
机构
[1] Univ Hosp Munster, Dept Obstet & Gynecol, Albert Schweitzer Campus 1, D-48149 Munster, Germany
[2] St Franziskus Hosp Ahlen, Dept Obstet & Gynecol, Ahlen, Germany
[3] Univ Hosp Munster, Inst Biostat & Clin Res, Munster, Germany
来源
ULTRASCHALL IN DER MEDIZIN | 2020年 / 41卷 / 04期
关键词
preterm birth; cervical length; prenatal diagnosis; strain elastography; UTERINE CERVIX; PREGNANCY; RISK;
D O I
10.1055/a-0865-1711
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Purpose To evaluate cervical elastography strain pattern as a predictive marker for spontaneous preterm delivery (SPTD). Materials and Methods In this case- control study cervical length (CL) and elastographic data (strain ratio, elastography index, strain pattern score) were acquired from 335 pregnant women (20th - 34th week of gestation) by transvaginal ultrasound. Data of 50 preterm deliveries were compared with 285 normal controls. Strain ratio and elastography index were calculated by placing two regions of interest (ROIs) in parallel on the anterior cervical lip. The strain ratio was determined by dividing the higher strain value by the lower one. The elastography index was defined as the maximum of the strain ratio curve. Elastographic images were assigned a new established strain pattern (SP) score between 0 and 2 according to the distribution of strain induced by compression. Results Elastography index, SP score and CL differed between preterm and normal pregnancies (1.61 vs. 1.27, p < 0.001; SP score value of "2": n = 31 ( 62 %) vs. n = 36 (12.6 %), p < 0.001; CL 30.7 vs. 41.0 mm, p < 0.001; respectively). The elastography index and SP score were associated with a higher predictive potential than CL measurement alone (AUC 0.8059 (area under the curve); AUC 0.7716; AUC 0.7631; respectively). A combination of all parameters proved more predictive than any single parameter (AUC 0.8987; respectively). Conclusion Higher elastography index and SP scores were correlated with an elevated risk of SPTD and are superior to CL measurement as a predictive marker. A combination of these parameters could be used as a "Cervical Index" for the prediction of SPTD.
引用
收藏
页码:397 / 403
页数:7
相关论文
共 29 条
[11]   Quantitative cervical elastography during pregnancy: influence of setting features on strain calculation [J].
Fruscalzo, Arrigo ;
Londero, Ambrogio P. ;
Schmitz, Ralf .
JOURNAL OF MEDICAL ULTRASONICS, 2015, 42 (03) :387-394
[12]   Global report on preterm birth and stillbirth (2 of 7): discovery science [J].
Gravett, Michael G. ;
Rubens, Craig E. ;
Nunes, Toni M. .
BMC PREGNANCY AND CHILDBIRTH, 2010, 10
[13]   Quantitative sonoelastography of the uterine cervix by interposition of a synthetic reference material [J].
Hee, Lene ;
Sandager, Puk ;
Petersen, Olav ;
Uldbjerg, Niels .
ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2013, 92 (11) :1244-1249
[14]   Evaluation of cervical stiffness during pregnancy using semiquantitative ultrasound elastography [J].
Hernandez-Andrade, E. ;
Hassan, S. S. ;
Ahn, H. ;
Korzeniewski, S. J. ;
Yeo, L. ;
Chaiworapongsa, T. ;
Romero, R. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2013, 41 (02) :152-161
[15]   Strain at the internal cervical os assessed with quasi-static elastography is associated with the risk of spontaneous preterm delivery at ≤ 34 weeks of gestation [J].
Hernandez-Andrade, Edgar ;
Garcia, Maynor ;
Ahn, Hyunyoung ;
Korzeniewski, Steven J. ;
Saker, Homam ;
Yeo, Lami ;
Chaiworapongsa, Tinnakorn ;
Hassan, Sonia S. ;
Romero, Roberto .
JOURNAL OF PERINATAL MEDICINE, 2015, 43 (06) :657-666
[16]   Relationships Between Mechanical Properties and Extracellular Matrix Constituents of the Cervical Stroma During Pregnancy [J].
House, Michael ;
Kaplan, David L. ;
Socrate, Simona .
SEMINARS IN PERINATOLOGY, 2009, 33 (05) :300-307
[17]   The length of the cervix and the risk of spontaneous premature delivery [J].
Iams, JD ;
Goldenberg, RL ;
Meis, PJ ;
Mercer, BM ;
Moawad, A ;
Das, A ;
Thom, E ;
McNellis, D ;
Copper, RL ;
Johnson, F ;
Roberts, JM ;
Hauth, JC ;
Northern, A ;
Neely, C ;
MuellerHeubach, E ;
Swain, M ;
Frye, A ;
Lindheimer, M ;
Jones, P ;
Brown, MEL ;
Siddiqi, TA ;
Elder, N ;
Coombs, T ;
VanHorn, J ;
Bain, R ;
Leuchtenburg, L ;
Fischer, M ;
Harger, JH ;
Cotroneo, M ;
Stallings, C ;
Yaffe, S ;
Catz, C ;
Klebanoff, M ;
Landon, MB ;
Schneider, J ;
Mueller, C ;
Carey, JC ;
Meier, A ;
Liles, E ;
Newman, RB ;
Collins, BA ;
Metcalf, T ;
Odell, V ;
Sibai, B ;
Ramsey, R ;
Fricke, JL ;
Treadwell, M ;
Norman, GS .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 334 (09) :567-572
[18]   Breast disease: Clinical application of US elastography for diagnosis [J].
Itoh, A ;
Ueno, E ;
Tohno, E ;
Kamma, H ;
Takahashi, H ;
Shiina, T ;
Yamakawa, M ;
Matsumura, T .
RADIOLOGY, 2006, 239 (02) :341-350
[19]   Quantitative Elastography of the uterine cervix as a predictor of preterm delivery [J].
Koebbing, K. ;
Fruscalzo, A. ;
Hammer, K. ;
Moellers, M. ;
Falkenberg, M. ;
Kwiecien, R. ;
Klockenbusch, W. ;
Schmitz, R. .
JOURNAL OF PERINATOLOGY, 2014, 34 (10) :774-780
[20]   Challenging the in-vivo assessment of biomechanical properties of the uterine cervix: A critical analysis of ultrasound based quasi-static procedures [J].
Maurer, M. M. ;
Badir, S. ;
Pensalfini, M. ;
Bajka, M. ;
Abitabile, P. ;
Zimmermann, R. ;
Mazza, E. .
JOURNAL OF BIOMECHANICS, 2015, 48 (09) :1541-1548