Pulmonary Nodules With Ground-Glass Opacity Can Be Reliably Measured With Low-Dose Techniques Regardless of Iterative Reconstruction: Results of a Phantom Study

被引:23
作者
Siegelman, Jenifer W. [1 ]
Supanich, Mark P. [2 ]
Gavrielides, Marios A. [3 ]
机构
[1] Harvard Univ, Sch Med, Dept Radiol, Brigham & Womens Hosp,Ctr Evidence Based Imaging, Brookline, MA 02445 USA
[2] Rush Univ, Med Ctr, Dept Diagnost Radiol & Nucl Med, Chicago, IL 60612 USA
[3] US FDA, Div Imaging Diagnost & Software Reliabil DIDSR, Off Sci & Engn Labs, Ctr Devices & Radiol Hlth, Silver Spring, MD USA
关键词
ground-glass opacity; lung cancer; pulmonary nodule; quantitative imaging; volume measurement; LUNG-CANCER; SIZE ESTIMATION; CT; VOLUMETRY; CLASSIFICATION; INCREASE;
D O I
10.2214/AJR.14.13820
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Pulmonary nodules of ground-glass opacity represent one imaging manifestation of a slow-growing variant of lung cancer. The objective of this phantom study was to quantify the effect of the radiation dose used for the examination (volume CT dose index [CTDI vol]), type of reconstruction algorithm, and choice of postreconstruction enhancement algorithms on the measurement error when assessing the volume of simulated lung nodules with CT, focusing on two radiodensity levels. MATERIALS AND METHODS. Twelve synthetic nodules of two radiodensities (-630 and -10 HU), three shapes (spherical, lobulated, and spiculated), and two sizes (nominal diameters of 5 and 10 mm) were inserted into an anthropomorphic chest phantom and scanned with techniques varying in CTDI vol (from subscreening dose [0.8 mGy] to diagnostic levels [6.5 mGy]), reconstruction algorithms (iterative reconstruction and filtered back projection), and different postreconstruction enhancement algorithms. Nodule volume was measured from the resulting reconstructed CT images with a matched filter estimator. RESULTS. No significant over-or underestimation of nodule volume was observed across individual variables, with low percentage error overall (-1.4%) and for individual variables (range, -3.4% to 0.4%). The magnitude of percentage error was also low (overall average percentage error < 6% and SD values < 4.5%) and for individual variables (absolute percentage error range 3.3-5.6%). No clinically significant differences were observed between different levels of CTDI vol, use of iterative reconstruction algorithms, or use of different postreconstruction enhancement algorithms. CONCLUSION. These results indicate that, if validated for other measurement tools and scanners, lung nodule volume measurements from scans acquired and reconstructed with significantly different acquisition and reconstruction techniques can be reliably compared.
引用
收藏
页码:1242 / 1247
页数:6
相关论文
共 27 条
[1]   Reduced Lung-Cancer Mortality with Low-Dose Computed Tomographic Screening [J].
Aberle, Denise R. ;
Adams, Amanda M. ;
Berg, Christine D. ;
Black, William C. ;
Clapp, Jonathan D. ;
Fagerstrom, Richard M. ;
Gareen, Ilana F. ;
Gatsonis, Constantine ;
Marcus, Pamela M. ;
Sicks, JoRean D. .
NEW ENGLAND JOURNAL OF MEDICINE, 2011, 365 (05) :395-409
[2]   Volumetric quantification of lung nodules in CT with iterative reconstruction (ASiR and MBIR) [J].
Chen, Baiyu ;
Barnhart, Huiman ;
Richard, Samuel ;
Robins, Marthony ;
Colsher, James ;
Samei, Ehsan .
MEDICAL PHYSICS, 2013, 40 (11)
[3]   Quantitative CT: technique dependence of volume estimation on pulmonary nodules [J].
Chen, Baiyu ;
Barnhart, Huiman ;
Richard, Samuel ;
Colsher, James ;
Amurao, Maxwell ;
Samei, Ehsan .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (05) :1335-1348
[4]   Pulmonary Ground-Glass Nodules: Increase in Mass as an Early Indicator of Growth [J].
de Hoop, Bartjan ;
Gietema, Hester ;
van de Vorst, Saskia ;
Murphy, Keelin ;
van Klaveren, Rob J. ;
Prokop, Mathias .
RADIOLOGY, 2010, 255 (01) :199-206
[5]   A comparison of six software packages for evaluation of solid lung nodules using semi-automated volumetry: What is the minimum increase in size to detect growth in repeated CT examinations [J].
de Hoop, Bartjan ;
Gietema, Hester ;
van Ginneken, Bram ;
Zanen, Pieter ;
Groenewegen, Gerard ;
Prokop, Mathias .
EUROPEAN RADIOLOGY, 2009, 19 (04) :800-808
[6]   Accuracy of lung nodule volumetry in low-dose CT with iterative reconstruction: an anthropomorphic thoracic phantom study [J].
Doo, K. W. ;
Kang, E-Y ;
Yong, H. S. ;
Woo, O. H. ;
Lee, K. Y. ;
Oh, Y-W .
BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1041)
[7]   New response evaluation criteria in solid tumours: Revised RECIST guideline (version 1.1) [J].
Eisenhauer, E. A. ;
Therasse, P. ;
Bogaerts, J. ;
Schwartz, L. H. ;
Sargent, D. ;
Ford, R. ;
Dancey, J. ;
Arbuck, S. ;
Gwyther, S. ;
Mooney, M. ;
Rubinstein, L. ;
Shankar, L. ;
Dodd, L. ;
Kaplan, R. ;
Lacombe, D. ;
Verweij, J. .
EUROPEAN JOURNAL OF CANCER, 2009, 45 (02) :228-247
[8]   Combination of a Low-Tube-Voltage Technique With Hybrid Iterative Reconstruction (iDose) Algorithm at Coronary Computed Tomographic Angiography [J].
Funama, Yoshinori ;
Taguchi, Katsuyuki ;
Utsunomiya, Daisuke ;
Oda, Seitaro ;
Yanaga, Yumi ;
Yamashita, Yasuyuki ;
Awai, Kazuo .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2011, 35 (04) :480-485
[9]   Benefit of Overlapping Reconstruction for Improving the Quantitative Assessment of CT Lung Nodule Volume [J].
Gavrielides, Marios A. ;
Zeng, Rongping ;
Myers, Kyle J. ;
Sahiner, Berkman ;
Petrick, Nicholas .
ACADEMIC RADIOLOGY, 2013, 20 (02) :173-180
[10]   Information-Theoretic Approach for Analyzing Bias and Variance in Lung Nodule Size Estimation With CT: A Phantom Study [J].
Gavrielides, Marios A. ;
Zeng, Rongping ;
Kinnard, Lisa M. ;
Myers, Kyle J. ;
Petrick, Nicholas .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (10) :1795-1807