Practical considerations for image-based PSF and blobs reconstruction in PET

被引:34
作者
Stute, Simon [1 ]
Comtat, Claude [1 ]
机构
[1] CEA, Serv Hosp Frederic Joliot, Inst Imagerie BioMed I2BM, F-91401 Orsay, France
关键词
ITERATIVE RECONSTRUCTION; EDGE ARTIFACTS; EM ALGORITHM; SYSTEM; MATRIX; NOISE; PERFORMANCE; SIMULATION; PROJECTION; CT;
D O I
10.1088/0031-9155/58/11/3849
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Iterative reconstructions in positron emission tomography (PET) need a model relating the recorded data to the object/patient being imaged, called the system matrix (SM). The more realistic this model, the better the spatial resolution in the reconstructed images. However, a serious concern when using a SM that accurately models the resolution properties of the PET system is the undesirable edge artefact, visible through oscillations near sharp discontinuities in the reconstructed images. This artefact is a natural consequence of solving an ill-conditioned inverse problem, where the recorded data are band-limited. In this paper, we focus on practical aspects when considering image-based point-spread function (PSF) reconstructions. To remove the edge artefact, we propose to use a particular case of the method of sieves (Grenander 1981 Abstract Inference New York: Wiley), which simply consists in performing a standard PSF reconstruction, followed by a post-smoothing using the PSF as the convolution kernel. Using analytical simulations, we investigate the impact of different reconstruction and PSF modelling parameters on the edge artefact and its suppression, in the case of noise-free data and an exactly known PSF. Using Monte-Carlo simulations, we assess the proposed method of sieves with respect to the choice of the geometric projector and the PSF model used in the reconstruction. When the PSF model is accurately known, we show that the proposed method of sieves succeeds in completely suppressing the edge artefact, though after a number of iterations higher than typically used in practice. When applying the method to realistic data (i.e. unknown true SM and noisy data), we show that the choice of the geometric projector and the PSF model does not impact the results in terms of noise and contrast recovery, as long as the PSF has a width close to the true PSF one. Equivalent results were obtained using either blobs or voxels in the same conditions (i.e. the blob's density function being the same as the voxel-based PSF). From a practical point-of-view, the method can be used to perform fast reconstructions based on very simple models (compared to sinogram-based PSF modelling), producing artefact-free images with a better compromise between noise and spatial resolution than images reconstructed without or with under-estimated PSF. Besides, the method inherently limits the spatial resolution in the reconstructed images to the intrinsic one of the PET system.
引用
收藏
页码:3849 / 3870
页数:22
相关论文
共 45 条
[1]   Geometrical and Monte Carlo projectors in 3D PET reconstruction [J].
Aguiar, Pablo ;
Rafecas, Magdalena ;
Enrique Ortuno, Juan ;
Kontaxakis, George ;
Santos, Andres ;
Pavia, Javier ;
Ros, Domenec .
MEDICAL PHYSICS, 2010, 37 (11) :5691-5702
[2]  
Ahn S, 2011, IEEE NUCL SCI CONF R, P4110, DOI 10.1109/NSSMIC.2011.6153783
[3]  
Bai B, 2010, IEEE NUCL SCI CONF R, P2263, DOI 10.1109/NSSMIC.2010.5874186
[4]   ALGORITHM FOR COMPUTER CONTROL OF A DIGITAL PLOTTER [J].
BRESENHAM, JE .
IBM SYSTEMS JOURNAL, 1965, 4 (01) :25-30
[5]   Iterative algorithms for deblurring and deconvolution with constraints [J].
Byrne, C .
INVERSE PROBLEMS, 1998, 14 (06) :1455-1467
[6]   Non-Gaussian space-variant resolution modelling for list-mode reconstruction [J].
Cloquet, C. ;
Sureau, F. C. ;
Defrise, M. ;
Van Simaeys, G. ;
Trotta, N. ;
Goldman, S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (17) :5045-5066
[7]  
Daube-Witherspoon ME, 2002, J NUCL MED, V43, P1398
[8]   Distance-driven projection and backprojection in three dimensions [J].
De Man, B ;
Basu, S .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11) :2463-2475
[9]  
Grenander, 1981, WILEY SERIES PROBABI
[10]  
Herman G.T., 1980, Image Reconstruction from Projections. The Fundamentals of Computerirzed Tomography