Comparison of CZT SPECT and conventional SPECT for assessment of contractile function, mechanical synchrony and myocardial scar in patients with heart failure

被引:11
作者
Wu, Dayong [1 ,2 ,3 ]
Zhang, Zongyao [1 ,2 ]
Ma, Rongzheng [1 ,2 ]
Guo, Feng [1 ,2 ]
Wang, Lei [1 ,2 ]
Fang, Wei [1 ,2 ]
机构
[1] Chinese Acad Med Sci, Fuwai Hosp, Dept Nucl Med, Natl Ctr Cardiovasc Dis, Beijing, Peoples R China
[2] Peking Union Med Coll, Beijing, Peoples R China
[3] Hebei Gen Hosp, Dept Nucl Med, Shijiazhuang, Hebei, Peoples R China
关键词
SPECT; CZT; left ventricular function; mechanical synchrony; myocardial scar; heart failure; LEFT-VENTRICULAR FUNCTION; CARDIAC RESYNCHRONIZATION; PERFUSION SPECT; GATED SPECT; PHASE-ANALYSIS; GAMMA-CAMERA; TASK-FORCE; HIGH-SPEED; DYSSYNCHRONY; ASSOCIATION;
D O I
10.1007/s12350-017-0952-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
AimThe aim of this study was to compare CZT-SPECT (CZT SPECT) to conventional SPECT (C-SPECT) in the assessment of left ventricular myocardial scar, contractile function, and mechanical synchrony in patients with heart failure (HF).MethodsFifty-nine patients with HF who were referred for myocardial perfusion/metabolism imaging were enrolled. All patients underwent resting Tc-99m-MIBI gated myocardial perfusion imaging using a CZT SPECT camera and a C-SPECT camera, respectively, and F-18-FDG PET myocardial metabolism imaging within three days. Summed rest score (SRS) and total perfusion defect (TPD) (as indices of perfusion abnormality), left ventricular (LV), end diastolic volume (EDV), end systolic volume (ESV), and ejection fraction (EF) (as indices of LV systolic function), and histogram band width (BW) and standard deviation (SD) (as indices of mechanical synchrony) were analyzed by automated software while the perfusion/metabolism patterns were analyzed visually.ResultsThere was a good correlation between CZT SPECT and C-SPECT for SRS and TPD. CZT SPECT tended to underestimate SRS and TPD compared to C-SPECT. CZT-SPECT and C-SPECT showed excellent agreement in assessing the perfusion/metabolism pattern though a small proportion of normal segments (6.6%) identified by CZT/PET exhibited mismatch pattern on C-SPECT/PET. CZT SPECT also showed excellent correlation with C-SPECT in measuring EDV, ESV, and EF. Finally, BW and SD measured by CZT SPECT correlated well with C-SPECT but CZT SPECT tended to overestimate BW and SD compared to C-SPECT.ConclusionCZT SPECT provided comparable data to C-SPECT for measuring LV scar, function and synchrony at a considerable reduction in imaging time. CZT SPECT holds a promise for comprehensive evaluation of myocardial performance in patients with HF.
引用
收藏
页码:443 / 452
页数:10
相关论文
共 32 条
[1]   Cardiac resynchronization in chronic heart failure [J].
Abraham, WT ;
Fisher, WG ;
Smith, AL ;
Delurgio, DB ;
Leon, AR ;
Loh, E ;
Kocovic, DZ ;
Packer, M ;
Clavell, AL ;
Hayes, DL ;
Ellestad, M ;
Messenger, J ;
Trupp, RJ ;
Underwood, J ;
Pickering, F ;
Truex, C ;
McAtee, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2002, 346 (24) :1845-1853
[2]   Performance of cardiac cadmium-zinc-telluride gamma camera imaging in coronary artery disease: a review from the cardiovascular committee of the European Association of Nuclear Medicine (EANM) [J].
Agostini, Denis ;
Marie, Pierre-Yves ;
Ben-Haim, Simona ;
Rouzet, Francois ;
Songy, Bernard ;
Giordano, Alessandro ;
Gimelli, Alessia ;
Hyafil, Fabien ;
Sciagra, Roberto ;
Bucerius, Jan ;
Verberne, Hein J. ;
Slart, Riemer H. J. A. ;
Lindner, Oliver .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 (13) :2423-2432
[3]   Left Ventricular Function Assessment Using 2 Different Cadmium-Zinc-Telluride Cameras Compared with a γ-Camera with Cardiofocal Collimators: Dynamic Cardiac Phantom Study and Clinical Validation [J].
Bailliez, Alban ;
Lairez, Olivier ;
Merlin, Charles ;
Piriou, Nicolas ;
Legallois, Damien ;
Blaire, Tanguy ;
Agostini, Denis ;
Valette, Frederic ;
Manrique, Alain .
JOURNAL OF NUCLEAR MEDICINE, 2016, 57 (09) :1370-1375
[4]   Segmental and global left ventricular function assessment using gated SPECT with a semiconductor Cadmium Zinc Telluride (CZT) camera: Phantom study and clinical validation vs cardiac magnetic resonance [J].
Bailliez, Alban ;
Blaire, Tanguy ;
Mouquet, Frederic ;
Legghe, R. ;
Etienne, B. ;
Legallois, Damien ;
Agostini, Denis ;
Manrique, Alain .
JOURNAL OF NUCLEAR CARDIOLOGY, 2014, 21 (04) :712-722
[5]   Cardiac resynchronization therapy - Part 1 - Issues before device implantation [J].
Bax, JJ ;
Abraham, T ;
Barold, SS ;
Breithardt, OA ;
Fung, JWH ;
Garrigue, S ;
Gorcsan, J ;
Hayes, DL ;
Kass, DA ;
Knuuti, J ;
Leclercq, C ;
Linde, C ;
Mark, DB ;
Monaghan, MJ ;
Nihoyannopoulos, P ;
Schalij, MJ ;
Stellbrink, C ;
Yu, CM .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (12) :2153-2167
[6]   Quantitative Gated SPECT-Derived Phase Analysis on Gated Myocardial Perfusion SPECT Detects Left Ventricular Dyssynchrony and Predicts Response to Cardiac Resynchronization Therapy [J].
Boogers, Mark M. ;
Van Kriekinge, Serge D. ;
Henneman, Maureen M. ;
Ypenburg, Claudia ;
Van Bommel, Rutger J. ;
Boersma, Eric ;
Dibbets-Schneider, Petra ;
Stokkel, Marcel P. ;
Schalij, Martin J. ;
Berman, Daniel S. ;
Germano, Guido ;
Bax, Jeroen J. .
JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (05) :718-725
[7]   Ultrafast nuclear myocardial perfusion imaging on a new gamma camera with semiconductor detector technique: first clinical validation [J].
Buechel, Ronny R. ;
Herzog, Bernhard A. ;
Husmann, Lars ;
Burger, Irene A. ;
Pazhenkottil, Aju P. ;
Treyer, Valerie ;
Valenta, Ines ;
von Schulthess, Patrick ;
Nkoulou, Rene ;
Wyss, Christophe A. ;
Kaufmann, Philipp A. .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2010, 37 (04) :773-778
[8]   Absolute Quantification of Left Ventricular Global and Regional Function at Nuclear MPI Using Ultrafast CZT SPECT: Initial Validation Versus Cardiac MR [J].
Cochet, Hubert ;
Bullier, Eric ;
Gerbaud, Edouard ;
Durieux, Muriel ;
Godbert, Yann ;
Lederlin, Mathieu ;
Coste, Pierre ;
Barat, Jean-Louis ;
Laurent, Francois ;
Montaudon, Michel .
JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (04) :556-563
[9]  
Dilsizian V., 2009, J. Nucl. Cardio, V16, P651
[10]   Reduced stress dose with rapid acquisition CZT SPECT MPI in a non-obese clinical population: Comparison to coronary angiography [J].
Duvall, W. Lane ;
Sweeny, Joseph M. ;
Croft, Lori B. ;
Ginsberg, Eric ;
Guma, Krista A. ;
Henzlova, Milena J. .
JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (01) :19-27