Automated Tube Voltage Adaptation in Combination with Advanced Modeled Iterative Reconstruction in Thoracoabdominal Third-Generation 192-Slice Dual-Source Computed Tomography: Effects on Image Quality and Radiation Dose

被引:24
作者
Scholtz, Jan-Erik [1 ]
Wichmann, Julian L. [1 ]
Huesers, Kristina [1 ]
Beeres, Martin [1 ]
Nour-Eldin, Nour-Eldin Abdelrehim [1 ,2 ]
Frellesen, Claudia [1 ]
Vogl, Thomas J. [1 ]
Lehnert, Thomas [1 ]
机构
[1] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
[2] Cairo Univ Hosp, Diagnost & Intervent Radiol Dept, Cairo, Egypt
关键词
Computed tomography; automated tube voltage adaptation; radiation dose; image quality; CT ANGIOGRAPHY; ABDOMINAL CT; EXPOSURE CONTROL; REDUCTION; NECK; SELECTION; CHEST;
D O I
10.1016/j.acra.2015.05.010
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives: To evaluate image quality and radiation exposure of portal venous-phase thoracoabdominal third-generation 192-slice dual-source computed tomography (DSCT) with automated tube voltage adaptation (TVA) in combination with advanced modeled iterative reconstruction (ADMIRE). Materials and Methods: Fifty-one patients underwent oncologic portal venous-phase thoracoabdominal follow-up CT twice within 7 months. The initial examination was performed on second-generation 128-slice DSCT with fixed tube voltage of 120 kV in combination with filtered back projection reconstruction. The second examination was performed on a third-generation 192-slice DSCT using automated TVA in combination with ADMIRE. Attenuation and image noise of liver, spleen, renal cortex, aorta, vena cava inferior, portal vein, psoas muscle, and perinephric fat were measured. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Radiation dose was assessed as size-specific dose estimates (SSDE). Subjective image quality was assessed by two observers using five-point Likert scales. Interobserver agreement was calculated using intraclass correlation coefficients (ICC). Results: Automated TVA set tube voltage to 90 kV (n = 8), 100 kV (n = 31), 110 kV (n = 11), or 120 kV (n = 1). Average SSDE was decreased by 34.9% using 192-slice DSCT compared to 128-slice 120-kV DSCT (7.8 +/- 2.4 vs. 12.1 +/- 3.2 mGy; P < .001). Image noise was substantially lower; SNR and CNR were significantly increaeed in 192-slice DSCT compared to 128-slice DSCT (all P < .005). Image quality was voted excellent for both acquisition techniques (5.00 vs. 4.93; P = .083). Conclusions: Automated TVA in combination with ADMIRE on third-generation 192-slice DSCT in portal venous-phase thoracoabdominal CT provides excellent image quality with reduced image noise and increased SNR and CNR, whereas average radiation dose is reduced by 34.9% compared to 128-slice DSCT.
引用
收藏
页码:1081 / 1087
页数:7
相关论文
共 33 条
[1]  
[Anonymous], SIZ SPEC DOS EST SSD
[2]   Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience [J].
Bittencourt, Marcio Sommer ;
Schmidt, Bernhard ;
Seltmann, Martin ;
Muschiol, Gerd ;
Ropers, Dieter ;
Daniel, Werner Guenther ;
Achenbach, Stephan .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (07) :1081-1087
[3]   Acute Intracranial Hemorrhage in CT: Benefits of Sinogram-Affirmed Iterative Reconstruction Techniques [J].
Bodelle, B. ;
Klein, E. ;
Naguib, N. N. N. ;
Bauer, R. W. ;
Kerl, J. M. ;
Al-Butmeh, F. ;
Wichmann, J. L. ;
Ackermann, H. ;
Lehnert, T. ;
Vogl, T. J. ;
Schulz, B. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (03) :445-449
[4]   Slowing the Increase in the Population Dose Resulting from CT Scans [J].
Brenner, D. J. .
RADIATION RESEARCH, 2010, 174 (06) :809-815
[5]   Current concepts - Computed tomography - An increasing source of radiation exposure [J].
Brenner, David J. ;
Hall, Eric J. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (22) :2277-2284
[6]   Projected Cancer Risks From Computed Tomographic Scans Performed in the United States in 2007 [J].
de Gonzalez, Amy Berrington ;
Mahesh, Mahadevappa ;
Kim, Kwang-Pyo ;
Bhargavan, Mythreyi ;
Lewis, Rebecca ;
Mettler, Fred ;
Land, Charles .
ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (22) :2071-2077
[7]   Attenuation-based automatic kilovolt (kV)-selection in computed tomography of the chest: Effects on radiation exposure and image quality [J].
Eller, Achim ;
Wuest, Wolfgang ;
Scharf, Michael ;
Brand, Michael ;
Achenbach, Stephan ;
Uder, Michael ;
Lell, Michael M. .
EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (12) :2386-2391
[8]   Attenuation-Based Automatic Kilovolt Selection in Abdominal Computed Tomography Effects on Radiation Exposure and Image Quality [J].
Eller, Achim ;
May, Matthias S. ;
Scharf, Michael ;
Schmid, Axel ;
Kuefner, Michael ;
Uder, Michael ;
Lell, Michael M. .
INVESTIGATIVE RADIOLOGY, 2012, 47 (10) :559-565
[9]   Impact of Model-Based Iterative Reconstruction on Image Quality of Contrast-Enhanced Neck CT [J].
Gaddikeri, S. ;
Andre, J. B. ;
Benjert, J. ;
Hippe, D. S. ;
Anzai, Y. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2015, 36 (02) :391-396
[10]   CT iterative reconstruction in image space: A phantom study [J].
Ghetti, C. ;
Ortenzia, O. ;
Serreli, G. .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2012, 28 (02) :161-165