Measurements of scintillation efficiency and pulse shape for low energy recoils in liquid xenon

被引:75
作者
Akimov, D
Bewick, A
Davidge, D
Dawson, J
Howard, AS
Ivaniouchenkov, I
Jones, WG
Joshi, J
Kudryavtsev, VA
Lawson, TB
Lebedenko, V
Lehner, MJ
Lightfoot, PK
Liubarsky, I
Lüscher, R
McMillan, JE
Peak, CD
Quenby, JJ
Spooner, NJC
Sumner, TJ
Tovey, DR
Ward, CK
机构
[1] Univ Sheffield, Dept Phys & Astron, Sheffield S3 7RH, S Yorkshire, England
[2] Inst Theoret & Expt Phys, Moscow 117259, Russia
[3] Univ London Imperial Coll Sci Technol & Med, Blackett Lab, Dept Phys, London SW7 2BZ, England
关键词
liquid xenon; dark matter; WIMP; quenching factor; pulse shape;
D O I
10.1016/S0370-2693(01)01411-3
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Results of observations of low energy nuclear and electron recoil events in liquid xenon scintillator detectors are given. The relative scintillation efficiency for nuclear recoils is 0.22 +/- 0.01 in the recoil energy range 40-70 keV. Under the assumption of a single dominant decay component to the scintillation pulse shape the log-normal mean parameter To of the maximum likelihood estimator of the decay time constant for 6 keV < E-ee < 30 keV nuclear recoil events is equal to 21.0 +/- 0.5 ns. It is observed that for electron recoils T-0 rises slowly with energy, having a value similar to 30 ns at E-ee similar to 15 keV. Electron and nuclear recoil pulse shapes are found to be well fitted by single exponential functions although some evidence is found for a double exponential form for the nuclear recoil pulse shape. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:245 / 251
页数:7
相关论文
共 19 条
  • [1] [Anonymous], NUCLEONICS
  • [2] Scintillation efficiency of nuclear recoil in liquid xenon
    Arneodo, F
    Baiboussinov, B
    Badertscher, A
    Benetti, P
    Bernardini, E
    Bettini, A
    di Tiogliole, AB
    Brunetti, R
    Bueno, A
    Calligarich, E
    Campanelli, M
    Carpanese, C
    Cavalli, D
    Cavanna, F
    Cennini, P
    Centro, S
    Cesana, A
    Cline, D
    De Mitri, I
    Dolfini, R
    Ferrari, A
    Berzolari, AG
    Matthey, C
    Mauri, F
    Mazza, D
    Mazzone, L
    Meng, G
    Montanari, C
    Nurzia, G
    Otwinowski, S
    Palamara, O
    Pascoli, D
    Pepato, A
    Petrera, S
    Periale, L
    Piano Mortari, G
    Piazzoli, A
    Picchi, P
    Pietropaolo, F
    Rancati, T
    Rappoldi, A
    Raselli, GL
    Rebuzzi, D
    Revo, JP
    Rico, J
    Rossella, M
    Rossi, C
    Rubbia, A
    Rubbia, C
    Sala, P
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 449 (1-2) : 147 - 157
  • [3] WIMPS SEARCH WITH LOW ACTIVITY NAI CRYSTALS - PRELIMINARY-RESULTS
    BACCI, C
    BELLI, P
    BERNABEI, R
    DAI, CJ
    DING, LK
    GAILLARD, E
    GERBIER, G
    KUANG, HH
    INCICCHITTI, A
    MALLET, J
    MARCOVALDI, R
    MOSCA, L
    PROSPERI, D
    TAO, C
    XIE, YG
    [J]. PHYSICS LETTERS B, 1992, 293 (3-4) : 460 - 464
  • [4] Installation of the Cryogenic Dark Matter Search (CDMS)
    Barnes, PD
    DaSilva, A
    Akerib, DS
    Bauer, D
    Brink, P
    Cabrera, B
    Caldwell, DO
    Chugg, B
    Clarke, RM
    Cummings, A
    Davies, A
    Diaz, RC
    Dougherty, BL
    Emes, J
    Golwala, SR
    Hale, D
    Haller, EE
    Irwin, KD
    Knowlton, WB
    Kuziminov, V
    Lu, A
    Nam, SW
    Penn, MJ
    Novikov, V
    Pritychenko, BV
    Queinnec, F
    Ross, RR
    Sadoulet, B
    Seitz, D
    Shutt, T
    Smith, A
    Smith, G
    Sonnenschein, A
    Stockwell, W
    Taylor, JD
    Therrien, R
    Trumbull, TL
    White, S
    Wolgast, RC
    Yellin, S
    Young, BA
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 370 (01) : 233 - 236
  • [5] New limits on particle dark matter search with a liquid Xenon target-scintillator
    Bernabei, R
    Belli, P
    Montecchia, F
    Incicchitti, A
    Prosperi, D
    Dai, CJ
    Angelone, M
    Batistoni, P
    Pillon, M
    [J]. PHYSICS LETTERS B, 1998, 436 (3-4) : 379 - 388
  • [6] THE SCINTILLATION EFFICIENCY FOR CALCIUM AND FLUORINE RECOILS IN CAF2 AND CARBON AND FLUORINE RECOILS IN C6F6 FOR DARK-MATTER SEARCHES
    DAVIES, GJ
    SPOONER, NJC
    DAVIES, JD
    PYLE, GJ
    BUCKNELL, TD
    SQUIER, GTA
    LEWIN, JD
    SMITH, PF
    [J]. PHYSICS LETTERS B, 1994, 322 (1-2) : 159 - 165
  • [7] LIQUID XENON AS A DARK-MATTER DETECTOR - PROSPECTS FOR NUCLEAR RECOIL DISCRIMINATION BY PHOTON TIMING
    DAVIES, GJ
    DAVIES, JD
    LEWIN, JD
    SMITH, PF
    JONES, WG
    [J]. PHYSICS LETTERS B, 1994, 320 (3-4) : 395 - 399
  • [8] PULSE SHAPE-DISCRIMINATION WITH A LARGE NAI CRYSTAL
    DOLL, P
    FINK, G
    HAUPENTHAL, M
    FINLAY, RW
    HAUBER, S
    KLAGES, HO
    SCHIELER, H
    SMEND, F
    WICKE, GD
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 285 (03) : 464 - 468
  • [9] DETECTABILITY OF CERTAIN DARK-MATTER CANDIDATES
    GOODMAN, MW
    WITTEN, E
    [J]. PHYSICAL REVIEW D, 1985, 31 (12): : 3059 - 3063
  • [10] Experiments aiming at direct detection of dark matter
    Klapdor-Kleingrothaus, HV
    Ramachers, Y
    [J]. EUROPEAN PHYSICAL JOURNAL A, 1998, 3 (01) : 85 - 92